Catherine Heatley

Publications and source records attributed to Catherine Heatley.

3 recordsLinked to original sources

Objective measurement of intraocular lens movement and dioptric change with a focus shift accommodating intraocular lens.

PURPOSE: To objectively measure the shift and refractive change of the 1CU accommodating intraocular lens (IOL) (HumanOptics) and compare them to that of a monofocal AcrySof MA30 IOL (Alcon Laboratories) in the fellow eye. SETTING: Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. METHODS: Thirty patients who had bilateral cataract surgery 18 to 24 months previously with a 1CU IOL prospectively randomly allocated to 1 eye and an AcrySof MA30 monofocal IOL to the other eye were examined. Distance correction, near vision, reading fluency, near point, and defocus to minus spheres were measured. Intraocular lens shift to an accommodative stimulus following instillation of pilocarpine 4% was measured with the ACMaster. Refractive change between distance and near was measured with the Tracey wavefront analyzer. RESULTS: Of the original 30 patients recruited, complete measurements could only be obtained for 20. There was no significant difference in near visual function with either IOL. A small anterior movement of the 1CU was seen with accommodation 0.010 mm +/- 0.028 (SD). After pilocarpine 4% instillation, a forward movement of 0.220 +/- 0.169 mm was seen with the 1CU compared to a backward movement of 0.028 +/- 0.095 with the MA30. There was no significant correlation between distance corrected near visual acuity and IOL movement. No change in spherical equivalent between distance and near was seen on wavefront analysis of either IOL. CONCLUSIONS: Small forward movement of the 1CU IOL was seen with accommodation and increased following pilocarpine, compared to the posterior movement of the MA30 IOL. The amount of the IOL shift was not sufficient to provide useful near vision, but the difference suggests that the engineering concept behind the 1CU IOL is valid.

Accommodation, Ocular↗

Correlation between the measurement of posterior capsule opacification severity and visual function testing.

PURPOSE: To develop software to measure the severity of posterior capsule opacification (PCO) using analysis of retroillumination images and to correlate the results with clinical evaluation of PCO severity and visual function. SETTING: Department of Physics, King's College, and Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. METHODS: A technique for calculating PCO severity was developed based on calculating the variance of intensity by transforming retroillumination images to a similar mean intensity. The computer-derived severity was compared to grading of clinical severity by 3 independent observers using a library of 100 retroillumination images ranging from clear posterior capsules to very severe PCO. The computer results were also compared with the following other current methods of measuring PCO: Evaluation of Posterior Capsule Opacification (EPCO), POCOman, and Automated Quantification of After-Cataract. A further 35 images were used to compare the results of computer-derived severity with the results of visual function analysis (high-contrast acuity, 100%; low-contrast acuity, 9%) using the Early Treatment Diabetic Retinopathy Study chart, contrast sensitivity testing using the Pelli-Robson chart, and glare assessment using the van den Berg straylight meter. RESULTS: The severity scores showed a good correlation with clinical severity scores for the library of images (r=0.86) and with severity scores using POCOman and EPCO (r=0.85 and r=0.81, respectively). The correlations with visual function tests were also good, with low-contrast visual acuity (9%) showing the best correlation (r=0.87). CONCLUSION: Variance in intensity of PCO was successfully used to calculate the severity of PCO.

Aged↗

POCOman: new system for quantifying posterior capsule opacification.

PURPOSE: To describe a new method of measuring posterior capsule opacification (PCO) and intraocular lens (IOL) rotation and report the validation of the method. SETTING: Ophthalmology Department, St. Thomas' Hospital, and Medical Imaging, Department of Physics, King's College, London, United Kingdom. METHOD: A new interactive software program, POCOman, was developed for the semiobjective assessment of PCO. Digital images of the posterior capsule, which can be acquired by any technique, are analyzed by the observer to determine the percentage area of PCO and assign a severity score. The system was validated by comparing it to clinical slitlamp evaluation of PCO and automated POCO system analysis using a library of 100 images taken from archives. The software also measures sequential IOL rotation for the evaluation of toric IOLs. RESULTS: An image could be analyzed in approximately 2 minutes. The results of the POCOman system correlated well with the results of the automated POCO system and clinical evaluation. CONCLUSIONS: The POCOman is an effective, user-friendly system for quantifying PCO. It can be obtained for free and has advantages over other methods.

Cataract↗