Rapid and high-throughput forensic short tandem repeat typing using a 96-lane microfabricated capillary array electrophoresis microdevice.

A 96-channel microfabricated capillary array electrophoresis (muCAE) device was evaluated for forensic short tandem repeat (STR) typing using PowerPlex 16 and AmpFlSTR Profiler Plus multiplex PCR systems. The high-throughput muCAE system produced high-speed <30-min parallel sample separations with single-base resolution. Forty-eight previously analyzed single-source samples were accurately typed, as confirmed on an ABI Prism 310 and/or the Hitachi FMBIO II. Minor alleles in 3:1 mixture samples containing female and male DNA were reliably typed as well. The instrument produced full profiles from sample DNA down to 0.17 ng, a threshold similar to that found for the ABI 310. Seventeen nonprobative samples from various evidentiary biological stains were also correctly typed. The successful application of the muCAE device to actual forensic STR typing samples is a significant step toward the development of a completely integrated STR analysis microdevice.

Alleles↗

Improving efficiency of a small forensic DNA laboratory: validation of robotic assays and evaluation of microcapillary array device.

AIM: To present validation studies performed for the implementation of existing and new technologies to increase the efficiency in the forensic DNA Section of the Palm Beach County Sheriff's Office (PBSO) Crime Laboratory. METHODS: Using federally funded grants, internal support, and an external Process Mapping Team, the PBSO collaborated with forensic vendors, universities, and other forensic laboratories to enhance DNA testing procedures, including validation of the DNA IQ magnetic bead extraction system, robotic DNA extraction using the BioMek2000, the ABI7000 Sequence Detection System, and is currently evaluating a micro Capillary Array Electrophoresis device. RESULTS: The PBSO successfully validated and implemented both manual and automated Promega DNA IQ magnetic bead extractions system, which have increased DNA profile results from samples with low DNA template concentrations. The Beckman BioMek2000 DNA robotic workstation has been validated for blood, tissue, bone, hair, epithelial cells (touch evidence), and mixed stains such as semen. There has been a dramatic increase in the number of samples tested per case since implementation of the robotic extraction protocols. The validation of the ABI7000 real-time quantitative polymerase chain reaction (qPCR) technology and the single multiplex short tandem repeat (STR) PowerPlex16 BIO amplification system has provided both a time and a financial benefit. In addition, the qPCR system allows more accurate DNA concentration data and the PowerPlex 16 BIO multiplex generates DNA profiles data in half the time when compared to PowerPlex1.1 and PowerPlex2.1 STR systems. The PBSO's future efficiency requirements are being addressed through collaboration with the University of California at Berkeley and the Virginia Division of Forensic Science to validate microcapillary array electrophoresis instrumentation. Initial data demonstrated the electrophoresis of 96 samples in less than twenty minutes. CONCLUSION: The PBSO demonstrated, through the validation of more efficient extraction and quantification technology, an increase in the number of evidence samples tested using robotic/DNA IQ magnetic bead DNA extraction, a decrease in the number of negative samples amplified due to qPCR and implementation of a single multiplex amplification system. In addition, initial studies show the microcapillary array electrophoresis device (microCAE) evaluation results provide greater sensitivity and faster STR analysis output than current platforms.

California↗

Validation and implementation of the PowerPlex 16 BIO System STR multiplex for forensic casework.

The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.

Alleles↗

Characterization and validation studies of powerPlex 2.1, a nine-locus short tandem repeat (STR) multiplex system and penta D monoplex.

In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.

Animals↗