Feasibility of delivering grid therapy using a multileaf collimator.

The feasibility of using a multileaf collimator (MLC) for grid therapy is demonstrated in this study. Grids with the projected field openings of 10 mm x 10 mm and 5 mm x 5 mm were created using multiple MLC-shaped fields. The deposited doses were measured with films at different depths in a solid water phantom and compared to those of Cerrobend grid collimators of similar hole sizes and hole separations. At the depth of maximum dose (dmax), the valley-to-peak dose ratios of the MLC grids were found to be about 11% and 19% for the respective 10 mm x 10 mm and 5 mm X 5 mm grid openings, and those of the corresponding grid blocks were about 15% and 20%. To quantify the dose contributed by transmission in the blocked areas due to the limited leaf thickness, Monte Carlo simulations (based on convolution/superposition method) were performed to calculate the doses in the solid water phantom using an ideal MLC with no leakage and perfect divergence in both the leaf end and side. About 7% reduction in the valley-to-peak dose ratio was found for both grid sizes at dmax. The results clearly showed that MLCs can be used to provide grid treatments with at least as good dosimetric properties as those of the Cerrobend grid blocks, though the former would in general require a longer delivery time.

Dose Fractionation, Radiation↗

An improved MLC segmentation algorithm and software for step-and-shoot IMRT delivery without tongue-and-groove error.

We present an improved multileaf collimator (MLC) segmentation algorithm, denoted by SLS(NOTG) (static leaf sequencing with no tongue-and-groove error), for step-and-shoot intensity-modulated radiation therapy (IMRT) delivery. SLS(NOTG) is an improvement over the MLC segmentation algorithm called SLS that was developed by Luan et al. [Med. Phys. 31(4), 695-707 (2004)], which did not consider tongue-and-groove error corrections. The aims of SLS(NOTG) are (1) shortening the treatment times of IMRT plans by minimizing their numbers of segments and (2) minimizing the tongue-and-groove errors of the computed IMRT plans. The input to SLS(NOTG) is intensity maps (IMs) produced by current planning systems, and its output is (modified) optimized leaf sequences without tongue-and-groove error. Like the previous SLS algorithm [Luan et al., Med. Phys. 31(4), 695-707 (2004)], SLS(NOTG) is also based on graph algorithmic techniques in computer science. It models the MLC segmentation problem as a weighted minimum-cost path problem, where the weight of the path is the number of segments and the cost of the path is the amount of tongue-and-groove error. Our comparisons of SLS(NOTG) with CORVUS indicated that for the same intensity maps, the numbers of segments computed by SLS(NOTG) are up to 50% less than those by CORVUS 5.0 on the Elekta LINAC system. Our clinical verifications have shown that the dose distributions of the SLS(NOTG) plans do not have tongue-and-groove error and match those of the corresponding CORVUS plans, thus confirming the correctness of SLS(NOTG). Comparing with existing segmentation methods, SLS(NOTG) also has two additional advantages: (1) SLS(NOTG) can compute leaf sequences whose tongue-and-groove error is minimized subject to a constraint on the maximum allowed number of segments, which may be desirable in clinical situations where a treatment with the complete correction of tongue-and-groove error takes too much time, and (2) SLS(NOTG) can be used to minimize a more general type of error called the tongue-or-groove error.

Algorithms↗

Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study.

Significant differences between planned and delivered treatments may occur due to respiration-induced tumour motion, leading to underdosing of parts of the tumour and overdosing of parts of the surrounding critical structures. Existing methods proposed to counter tumour motion include breath-holds, gating and MLC-based tracking. Breath-holds and gating techniques increase treatment time considerably, whereas MLC-based tracking is limited to two dimensions. We present an alternative solution in which a robotic couch moves in real time in response to organ motion. To demonstrate proof-of-principle, we constructed a miniature adaptive couch model consisting of two movable platforms that simulate tumour motion and couch motion, respectively. These platforms were connected via an electronic feedback loop so that the bottom platform responded to the motion of the top platform. We tested our model with a seven-field step-and-shoot delivery case in which we performed three film-based experiments: (1) static geometry, (2) phantom-only motion and (3) phantom motion with simulated couch motion. Our measurements demonstrate that the miniature couch was able to compensate for phantom motion to the extent that the dose distributions were practically indistinguishable from those in static geometry. Motivated by this initial success, we investigated a real-time couch compensation system consisting of a stereoscopic infra-red camera system interfaced to a robotic couch known as the Hexapod, which responds in real time to any change in position detected by the cameras. Optical reflectors placed on a solid water phantom were used as surrogates for motion. We tested the effectiveness of couch-based motion compensation for fixed fields and a dynamic arc delivery cases. Due to hardware limitations, we performed film-based experiments (1), (2) and (3), with the robotic couch at a phantom motion period and dose rate of 16 s and 100 MU min(-1), respectively. Analysis of film measurements showed near-equivalent dose distributions (<or=2 mm agreement of corresponding isodose lines) for static geometry and motion-synchronized real-time robotic couch tracking-based radiation delivery.

Computer Systems↗

Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry.

Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CT scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging.

Biophysical Phenomena↗

Improving a scissor-action couch for conformal arc radiotherapy and radiosurgery.

We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob harnesses, double-track alignment plates, and a drop-in rod that attaches the couch to the concrete floor. These add-on components minimize the intercomponent motion of the couch's scissor elevator, which allows consistent treatment setup. The accuracy of our isocenter couch alignment is an improvement over the above devices, within 1 mm of their accuracy. The couch has been used with over 15 patients and with over 50 modulated conformal arc treatment deliveries at our institution.

Artifacts↗

Deformable image registration for the use of magnetic resonance spectroscopy in prostate treatment planning.

PURPOSE: There is now convincing evidence that prostate cancer cells lack the ability to produce and accumulate citrate. Using magnetic resonance spectroscopy imaging (MRSI), regions of absent or low citrate concentration in the prostate can be visualized at a resolution of a few mm. This new advancement provides not only a tool for early diagnosis and screening but also the opportunity for preferential targeting of radiation to regions of high tumor burden in the prostate. The differences in the shape and location of the prostate between MRSI imaging and treatment have been the major obstacle in integrating MRSI in radiation therapy treatment planning. The purpose of this study is to develop a reliable method for deforming the prostate and surrounding regions from the geometry of MRSI imaging to the geometry of treatment planning, so that the regions of high tumor burden identified by the MRSI study can be faithfully transferred to the images used for treatment planning. METHODS AND MATERIALS: Magnetic resonance spectroscopy imaging studies have been performed on 2 prostate cancer patients using a commercial MRSI system with an endorectal coil and coupling balloon. At the end of each study, we also acquired the MRI of the pelvic region at both the deformed state where the prostate is distorted by the endorectal balloon and the resting state with the endorectal balloon deflated and removed. The task is to find a three-dimensional matrix of transformation vectors for all volume elements that links the two image sets. We have implemented an optimization method to iteratively optimize the transformation vectors using a Newton-Ralphson algorithm. The objective function is based on the mutual information. The distorted images using the transformation vectors are compared with the images acquired at the resting conditions. RESULTS AND DISCUSSION: The algorithm is capable of performing the registration automatically without the need for intervention. It does not require manual contouring of the organs. By applying the algorithm to multiple image sets of different patients, we found a good agreement between the images transformed from those acquired at the deformed state and those acquired at resting conditions. The computation time required for achieving the registration is in the range of a half-hour (for image size: 256 pixels x 256 pixels x 25 slices). However, the space of registration can be restricted to speed up the process. CONCLUSION: In this article, we described a three-dimensional deformable image registration method to automatically transform images from the deformed imaging state to resting state. Our examples show that this method is feasible and useful to the treatment planning system.

Algorithms↗

A new MLC segmentation algorithm/software for step-and-shoot IMRT delivery.

We present a new MLC segmentation algorithm/software for step-and-shoot IMRT delivery. Our aim in this work is to shorten the treatment time by minimizing the number of segments. Our new segmentation algorithm, called SLS (an abbreviation for static leaf sequencing), is based on graph algorithmic techniques in computer science. It takes advantage of the geometry of intensity maps. In our SLS approach, intensity maps are viewed as three-dimensional (3-D) "mountains" made of unit-sized "cubes." Such a 3-D "mountain" is first partitioned into special-structured submountains using a new mixed partitioning scheme. Then the optimal leaf sequences for each submountain are computed by either a shortest-path algorithm or a maximum-flow algorithm based on graph models. The computations of SLS take only a few minutes. Our comparison studies of SLS with CORVUS (both the 4.0 and 5.0 versions) and with the Xia and Verhey segmentation methods on Elekta Linac systems showed substantial improvements. For instance, for a pancreatic case, SLS used only one-fifth of the number of segments required by CORVUS 4.0 to create the same intensity maps, and the SLS sequences took only 25 min to deliver on an Elekta SL 20 Linac system in contrast to the 72 min for the CORVUS 4.0 sequences (a three-fold improvement). To verify the accuracy of our new leaf sequences, we conducted film and ion-chamber measurements on phantom. The results showed that both the intensity distributions as well as dose distributions of the SLS delivery match well with those of CORVUS delivery. SLS can also be extended to other types of Linac systems.

Algorithms↗

Radiation absorbed dose distribution in a patient treated with yttrium-90 microspheres for hepatocellular carcinoma.

We have implemented a three-dimensional dose calculation technique accounting for dose inhomogeneity within the liver and tumor of a patient treated with 90Y microspheres. Single-photon emission computed tomography (SPECT) images were used to derive the activity distribution within liver. A Monte Carlo calculation was performed to create a voxel dose kernel for the 90Y source. The activity distribution was convolved with the voxel dose kernel to obtain the three-dimensional (3D) radiation absorbed dose distribution. An automated technique was developed to accurately register the computed tomography (CT) and SPECT scans in order to display the 3D dose distribution on the CT scans. In addition, dose-volume histograms were generated to fully analyze the tumor and liver doses. The calculated dose-volume histogram indicated that although the patient was treated to the nominal whole liver dose of 110 Gy, only 16% of the liver and 83% of the tumor received a dose higher than 110 Gy. The mean tumor and liver doses were 163 and 58 Gy, respectively.

Body Burden↗

The low alpha/beta ratio for prostate cancer: what does the clinical outcome of HDR brachytherapy tell us?

PURPOSE: Accumulating evidence demonstrates that prostate cancer has a low alpha/beta ratio. However, several challenging issues have been raised from previous studies, including the biologic equivalence between external beam radiotherapy (EBRT) and brachytherapy, the effect of relative biologic effectiveness (RBE) for permanent implantation, and the systematic uncertainties of multi-institutional and multi-modality clinical data. The purpose of this study is to address these issues by reexamining a reported clinical outcome of high-dose-rate (HDR) brachytherapy and to confirm the low alpha/beta ratio for prostate cancer. METHODS AND MATERIALS: The generalized linear-quadratic (LQ) model with considerations of sublethal damage repair and clonogen repopulation was used to calculate the cell-killing efficiency of radiotherapy treatments for prostate cancer. Standard models of tumor cure based on Poisson statistics were used to bridge cell killing to treatment outcome. The data collected in a clinical trial using EBRT plus HDR brachytherapy boost for prostate cancer at William Beaumont Hospital (WBH) were reanalyzed. A 4-year post-treatment time endpoint was chosen as compared to the 3-year endpoint used in the previous study because of better maturity and stability of the data. The least chi-square method was employed to fit the clinical data to estimate the LQ parameters as well as their confidence intervals. The number of clonogens for prostate tumors derived in a separate study was used as a constraint for the data modeling to improve the confidence level. RESULTS: Our analysis demonstrates that only relationships among the LQ parameters, not their definitive and unique values, can be derived from the WBH data set alone. This is due to the large statistical uncertainties, i.e., the small numbers of sampled patients. By combining with the results obtained with the clinical data from Memorial Sloan-Kettering Cancer Center (MSKCC), a new set of LQ parameters (alpha = 0.14 +/- 0.05 Gy(-1), alpha/beta = 3.1(-1.6)(+2.6) Gy) was obtained from the current analysis of the WBH data without dealing with data from permanent implants. The results are consistent with a previous study based on the biologic equivalence between EBRT and permanent implants with a consideration of tumor repopulation. This set of LQ parameters provides a consistent interpretation of clinical data currently available for prostate cancer. CONCLUSIONS: This study provides further evidence to support that prostate cancer has a low alpha/beta ratio of about 3.1 Gy. This study shows that the RBE effect in permanent implantation may not be clinically significant for prostate cancer. The consistency found between this analysis and the previous reported study supports the general biologic equivalence between EBRT and brachytherapy treatments for prostate cancer. The low alpha/beta ratio opens the door to search for more effective radiotherapeutic approaches for prostate cancer, e.g., hypofractionation radiotherapy.

Brachytherapy↗

An optimal algorithm for configuring delivery options of a one-dimensional intensity-modulated beam.

The problem of generating delivery options for one-dimensional intensity-modulated beams (1D IMBs) arises in intensity-modulated radiation therapy. In this paper, we present an algorithm with the optimal running time, based on the 'rightmost-preference' method, for generating all distinct delivery options for an arbitrary 1D IMB. The previously best known method for generating delivery options for a 1D IMB with N left leaf positions and N right leaf positions is a 'brute-force' solution, which first generates all N! possible combinations of the left and right leaf positions and then removes combinations that are not physically allowed delivery options. Compared with the brute-force method, our algorithm has several advantages: (1) our algorithm runs in an optimal time that is linearly proportional to the total number of distinct delivery options that it actually produces. Note that for a 1D IMB with multiple peaks, the total number of distinct delivery options in general tends to be considerably smaller than the worst case N!. (2) Our algorithm can be adapted to generating delivery options subject to additional constraints such as the 'minimum leaf separation' constraint. (3) Our algorithm can also be used to generate random subsets of delivery options; this feature is especially useful when the 1D IMBs in question have too many delivery options for a computer to store and process. The key idea of our method is that we impose an order on how left leaf positions should be paired with right leaf positions. Experiments indicated that our rightmost-preference algorithm runs dramatically faster than the brute-force algorithm. This implies that our algorithm can handle 1D IMBs whose sizes are substantially larger than those handled by the brute-force method. Applications of our algorithm in therapeutic techniques such as intensity-modulated arc therapy and 2D modulations are also discussed.

Computer Simulation↗

Physical aspects of yttrium-90 microsphere therapy for nonresectable hepatic tumors.

Administration of yttrium-90 microspheres via the hepatic artery is an attractive approach to selectively deliver therapeutic doses of radiation to liver malignancies. This procedure allows delivering radiation absorbed doses in excess of 100 Gy to the tumors without significant liver toxicity. The microsphere therapy involves different specialties including medical oncology, radiation oncology, nuclear medicine, interventional radiology, medical physics, and radiation safety. We have treated 80 patients with nonresectable hepatic tumors with yttrium-90 microspheres during the past two years on an institutional study protocol. The nominal radiation absorbed dose to the tumor in this study was 150 Gy. Required activity was calculated based on the nominal radiation absorbed dose and patient's liver volume obtained from the CT scan, assuming a uniform distribution of the microspheres within the liver. Microspheres were administered via a catheter placed into the hepatic artery. The actual radiation absorbed doses to tumors and normal liver tissue were calculated retrospectively based on the patient's 99mTc-MAA study and CT scans. As expected, the activity uptake within the liver was found to be highly nonuniform and multifold tumor to nontumor uptake was observed. A partition model was used to calculate the radiation absorbed dose within each region. For a typical patient the calculated radiation absorbed doses to the tumor and liver were 402 and 118 Gy, respectively. The radiation safety procedure involves confinement of the source and proper disposal of the contaminated materials. The average exposure rates at 1 m from the patients and on contact just anterior to the liver were 6 and 135 uSv/h, respectively. The special physics and dosimetry protocol developed for this procedure is presented.

Brachytherapy↗

Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee.

Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy since the advent of the medical linear accelerator. It allows the clinical implementation of highly conformal nonconvex dose distributions. This complex but promising treatment modality is rapidly proliferating in both academic and community practice settings. However, these advances do not come without a risk. IMRT is not just an add-on to the current radiation therapy process; it represents a new paradigm that requires the knowledge of multimodality imaging, setup uncertainties and internal organ motion, tumor control probabilities, normal tissue complication probabilities, three-dimensional (3-D) dose calculation and optimization, and dynamic beam delivery of nonuniform beam intensities. Therefore, the purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a viable and safe IMRT program. The scope of the IMRT program is quite broad, encompassing multileaf-collimator-based IMRT delivery systems, goal-based inverse treatment planning, and clinical implementation of IMRT with patient-specific quality assurance. This report, while not prescribing specific procedures, provides the framework and guidance to allow clinical radiation oncology physicists to make judicious decisions in implementing a safe and efficient IMRT program in their clinics.

Algorithms↗

A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions.

Treatment verification has been a weak link in external beam radiation therapy. As new and more complicated treatment techniques, such as intensity-modulated radiation therapy (IMRT), are implemented into clinical practice, verifying the accuracy of treatment delivery becomes increasingly important. Existing methods for treatment verification are highly labor intensive. We have developed a method for verifying the delivery of external beam radiotherapy and implemented the methodology into a system consisting of both hardware and software components. The system uses grayscale images acquired on the treatment machine from the planned treatment beams. From these images, the photon fluence distribution of each beam is derived. These measured photon fluence maps are then used as input to a separate dose calculation engine to compute the delivered absolute dose and the dose distribution in the same patient, assuming that the patient is set up as required by the treatment plan. The dose distribution generated from the measured fluence maps can then be compared to that of the treatment plan. Software tools, such as overlaying isodose curves generated with this method on those imported from the plan, dose difference maps, dose difference volume histograms, and three-dimensional perspective views of the dose differences, have also been developed. The system thus provides a means to verify the dose, the dose prescription, and the monitor units applied. The potential exists with a suitable electronic portal imaging system to reduce the quality assurance efforts, especially for IMRT.

Algorithms↗

Clinical implementation of intensity-modulated arc therapy.

PURPOSE: Intensity-modulated arc therapy (IMAT) is a method for delivering intensity-modulated radiation therapy (IMRT) using rotational beams. During delivery, the field shape, formed by a multileaf collimator (MLC), changes constantly. The objectives of this study were to (1) clinically implement the IMAT technique, and (2) evaluate the dosimetry in comparison with conventional three-dimensional (3D) conformal techniques. METHODS AND MATERIALS: Forward planning with a commercial system (RenderPlan 3D, Precision Therapy International, Inc., Norcross, GA) was used for IMAT planning. Arcs were approximated as multiple shaped fields spaced every 5-10 degrees around the patient. The number and ranges of the arcs were chosen manually. Multiple coplanar, superimposing arcs or noncoplanar arcs with or without a wedge were allowed. For comparison, conventional 3D conformal treatment plans were generated with the same commercial forward planning system as for IMAT. Intensity-modulated treatment plans were also created with a commercial inverse planning system (CORVUS, Nomos Corporation). A leaf-sequencing program was developed to generate the dynamic MLC prescriptions. IMAT treatment delivery was accomplished by programming the linear accelerator (linac) to deliver an arc and the MLC to step through a sequence of fields. Both gantry rotation and leaf motion were enslaved to the delivered MUs. Dosimetric accuracy of the entire process was verified with phantoms before IMAT was used clinically. For each IMAT treatment, a dry run was performed to assess the geometric and dosimetric accuracy. Both the central axis dose and dose distributions were measured and compared with predictions by the planning system. RESULTS: By the end of May 2001, 50 patients had completed their treatments with the IMAT technique. Two to five arcs were needed to achieve highly conformal dose distributions. The IMAT plans provided better dose uniformity in the target and lower doses to normal structures than 3D conformal plans. The results varied when the comparison was made with fixed gantry IMRT. In general, IMAT plans provided more uniform dose distributions in the target, whereas the inverse-planned fixed gantry treatments had greater flexibility in controlling dose to the critical structures. Because the field sizes and shapes used in the IMAT were similar to those used in conventional treatments, the dosimetric uncertainty was very small. Of the first 32 patients treated, the average difference between the measured and predicted doses was -0.54 +/- 1.72% at isocenter. The 80%-95% isodose contours measured with film dosimetry matched those predicted by the planning system to within 2 mm. The planning time for IMAT was slightly longer than for generating conventional 3D conformal plans. However, because of the need to create phantom plans for the dry run, the overall planning time was doubled. The average time a patient spent on the table for IMAT treatment was similar to conventional treatments. CONCLUSION: Initial results demonstrated the feasibility and accuracy of IMAT for achieving highly conformal dose distributions for different sites. If treatment plans can be optimized for IMAT cone beam delivery, we expect IMAT to achieve dose distributions that rival both slice-based and fixed-field IMRT techniques. The efficient delivery with existing linac and MLC makes IMAT a practical choice.

Brain Neoplasms↗