PubMed Health⌕ Search

Biomedical subjects

Cees Gooijer

Publications and source records attributed to Cees Gooijer.

25 records · Page 2Linked to original sources

Fast-gated intensified charge-coupled device camera to record time-resolved fluorescence spectra of tryptophan.

The possibilities of a 200 ps gated intensified charge-coupled device (CCD) camera to record time-resolved fluorescence were explored using the fluorescing amino acid tryptophan and its derivative Nacetyl-tryptophan amide (NATA) as model compounds. The results were compared to complementary data from time-correlated single-photon counting (TCSPC) experiments. If a spectral resolution of 1-2 nm is desired, the fast-gated intensified CCD (ICCD) camera is the method of choice. For a 10(-5) M tryptophan solution, time-resolved emission spectra and intensity decays (measured over 12 ns at 25 ps resolution) could be obtained in typically 10 minutes, giving the well-known lifetimes of 0.5 and 3 ns. In addition, a longer lifetime of 7 ns was found at the red edge of the spectrum. The very short gate time of the ICCD camera allowed us to observe a shift in the emission maximum of tryptophan even within the first nanosecond of decay of the fluorescence emission. As expected from the tryptophan rotamer model, such a shift is not observed in NATA. Using amplitudes obtained by global analysis, decay-associated spectra of these lifetimes were constructed.

Molecular Structure↗

Flavonoids in Leguminosae: analysis of extracts of T. pratense L., T. dubium L., T. repens L., and L. corniculatus L. leaves using liquid chromatography with UV, mass spectrometric and fluorescence detection.

Reversed-phase LC on C-18 bonded silica with a methanol-ammonium formate gradient was used to determine the main flavonoids in leaves of four species of the Leguminosae family. The detection modes were diode-array UV absorbance, fluorescence, and (tandem) mass spectrometry. LC-UV was used for a general screening, sub-classification, and the calculation of total flavonoid contents. LC-FLU was included to identify isoflavones on the basis of their native fluorescence. Most structural information regarding aglycons, sugar moieties, and acidic groups was derived from LC-MS in both the full-scan and extracted-ion mode, using negative-ion atmospheric pressure chemical ionization. MS/MS did not provide much additional information, because the same fragments were observed as in full-scan MS. In T. pratense and T. repens, the main constituents were flavonoid glucoside-(di)malonates, while T. dubium and L. corniculatus mainly contained flavonoid (di)glycosides. Satellite sets comprising an aglycon, the glucoside and glucoside-malonates or -acetates, were abundantly present only in T. pratense. Generally speaking, the main aglycons and sugars in the four plant species are surprisingly different. In addition, while the results for T. pratense are similar to those reported in the literature, there is little agreement in the case of the other species. Finally, total flavonoid contents ranged from 50-65 mg/g for L. corniculatus and T. dubium, to 15 mg/g for T. pratense and only 1 mg/g for T. repens.

Chromatography, High Pressure Liquid↗

Capillary electrophoresis coupled on-line with ultraviolet resonance Raman spectroscopy.

Capillary electrophoresis (CE) and resonance Raman spectroscopy (RRS) with excitation in the deep ultraviolet (UV) region (lambda(ex): 244 or 257 nm) were coupled on-line. The potential of this hyphenated technique, denoted as CE-UV-RRS, for analyte confirmation/identification purposes was explored with aromatic sulfonic acids and nucleotides as test compounds. Good-quality UV-RRS spectra could be recorded on-the-fly. Identification limits for the nucleotides were in the 10-125 microg/mL range. The RRS spectra showed sufficient characteristic features to enable analyte confirmation. In addition, the identification power of UV-RRS was studied with substituted pyrenes as model compounds. The compounds were distinguishable on the basis of their RRS spectra at 244 nm.

Journal Article↗

Liquid chromatography with atmospheric pressure chemical ionization and electrospray ionization mass spectrometry of flavonoids with triple-quadrupole and ion-trap instruments.

With 15 flavonoids as test compounds, the analytical performance of four modes of LC-MS, multiple MS (MSn) and tandem MS operation (atmospheric pressure chemical ionization (APCI), electrospray ionization, positive and negative ionization) was compared for two mass spectrometers, a triple-quadrupole and an ion-trap instrument. Two organic modifiers, methanol and acetonitrile, and two buffers, ammonium acetate and ammonium formate, were used. In general, the use of APCI in the negative ion mode gave the best response, with the signal intensities and the mass-spectral characteristics not differing significantly between the two instruments. The best results were obtained when methanol-ammonium formate (pH 4.0) was used as LC eluent. Under optimum conditions full-scan limits of detection of 0.1-30 mg/l were achieved in the negative APCI mode. Here it needs to be emphasized that up to 2-order response differences were found both between analytes and between modes of ionization. This implies that one should be very cautious when interpreting data on the screening of real-life samples. The main fragmentations observed in the MSn spectra on the ion-trap, or the tandem MS spectra on the triple-quadrupole were generally the same. The advantage of the former approach is the added possibility to ascertain precursor-->product ion relationships.

Atmospheric Pressure↗

Laser-induced quenched phosphorescence detection in capillary electrophoresis.

The feasibility of laser-based excitation for quenched phosphorescence detection in capillary electrophoresis (CE) was explored for the first time by using a small-size, quadrupled Nd-YAG laser emitting 266 nm pulses (duration, 0.4 ns) at a repetition rate of 7.8 kHz. To provide a continuous phosphorescence background, the phosphorophore 1-bromo-4-naphthalene sulfonic acid (BrNS) was added to the separation buffer. Both experiments and theory show that in laser-induced phosphorescence (LIP) - in contrast with lamp-excited phosphorescence - one normally deals with such high triplet-state phosphorophore concentrations that triplet-triplet annihilation is the major deactivation pathway. This results in a lower quantum yield of the analyte-induced bimolecular quenching interaction and, thus, the observed quenching signal. The situation can be improved by using a cylindrical lens for excitation in order to reduce the irradiance. In this case limits of detection (LODs) similar to those obtained using lamp excitation (1x10(-8) M) were achieved, while the width of the detection window was reduced from about 4 mm to 1 mm. Even under exclusion of triplet-triplet annihilation, i.e., under conditions of low irradiance, for our setup the quenching yields in LIP were smaller than in lamp-based phosphorescence detection. This is due to the repetition rate of the laser (7.8 kHz), which is too high in view of the phosphorescence lifetime (ca. 300 micros at low irradiance). Theory shows that this disadvantageous effect will be fully eliminated if the repetition rate is decreased to 1 kHz.

Electrons↗

Solvent influence on excited-state intramolecular proton transfer in 3-hydroxychromone derivatives studied by cryogenic high-resolution fluorescence spectroscopy.

High-resolution Shpol'skii spectra (recorded at 10 K in n-octane) of 3-hydroxychromone (3HC) substituted at the 2-position with a furan (3HC-F), a benzofuran (3HC-BF) or a naphthofuran group (3HC-NF) are presented. Being close analogues of 3-hydroxyflavone (3HF), these compounds can undergo excited-state intramolecular proton transfer (ESIPT). Luminescence can occur from the normal N* state (blue) or from the tautomeric T* state (green). Whether blue or green emission is observed is strongly dependent on hydrogen-bonding interactions with the environment. For all three chromones studied, high-resolution emission spectra in the green region (T*-->T) were obtained in pure n-octane, showing four sites with distinct emission bands and detailed vibrational structures, whereas no blue emission was detected. Contrary to the spectra published for 3HF, the emission lines were very narrow (line-broadening effects beyond detection) which implies that the ESIPT rate constants are >10(12) s(-1), at least 25 times lower than for 3HF. In order to study the effects of hydrogen-bonding solvents, four isomers of octanol (1-, 2-, 3- and 4-octanol) were added, forming 1:1 complexes with the 3HC derivatives. For all the combinations considered both blue and additional green emission was observed and in some cases narrow-banded spectra were obtained, mostly in the green. Only for the 3HC-NF/2-octanol complex, narrow-banded emission was found both in the blue and in the green region. It is demonstrated that these emissions come from different configurations of the complex. Possible structures for the two complex species are proposed, supported by semi-empirical calculations on complex formation enthalpies.

Chromones↗

Quenched phosphorescence detection in cyclodextrin-based electrokinetic chromatography.

Quenched phosphorescence detection is a sensitive detection method recently introduced in capillary zone electrophoresis. It is based on the dynamic quenching interaction of the analytes (quenchers) with a phosphorophore, 1-bromo-4-naphthalenesulfonate (BrNS), present in the separation buffer. In this study, it is shown that this detection method can also be used in cyclodextrin-based electrokinetic chromatography (CD-EKC) despite the presence in the buffer solution of cyclodextrins, which are known to reduce the luminescence quenching rate constants. Experiments indicate that BrNS mainly resides in the aqueous phase, while the analytes are distributed between both phases. In principle, the observed quenching might arise from the interaction of BrNS with uncomplexed as well as complexed analytes. However, from the dependence of the fractional quenching on the capacity factor (the normalized fractional quenching was found to be equal to the fraction of analyte in the aqueous phase), it was concluded that only aqueous-phase quenching contributes significantly to the observed quenching. Nevertheless, separation and detection can be regarded as fully compatible, because the capacity factors encountered in CD-EKC are generally low (in this study they ranged from about 0.1 to 2.5). Indeed, with nitroaromatic compounds as the target analytes, limits of detection in the 10(-8) M range were achieved.

Journal Article↗