PubMed Health⌕ Search

Biomedical subjects

Cemşit Karakurt

Publications and source records attributed to Cemşit Karakurt.

5 recordsLinked to original sources

Congenital partial pericardial defect and herniated right atrial appendage: a rare anomaly.

A congenital partial defect of the right-sided pericardium is a rare cardiac anomaly and it represents defective formation of the pleuropericardial membrane. Patients can be asymptomatic, but they may experience chest pain, myocardial ischemia, emboli, arrhythmia, and sudden death. In this report, we present an 8-month-old boy with pericardial defect and right atrial appendage herniation. It was diagnosed by echocardiography and cardiac magnetic resonance imaging.

Atrial Appendage↗

Single-pass lead VDD pacing system in children and adolescents: report of twenty-four patients.

The dual-chamber pacing systems allow for AV synchrony, but generally require the placement of two separate transvenous leads. Single-lead atrioventricular synchronous pacing system (VDD) using single-pass leads has been accepted as therapeutic alternative for atrioventricular block with normal sinus node function. The aim of this study is to evaluate clinical performance of single-pass lead VDD pacing systems in 24 consecutive patients in a ten-year period. The study group includes 17 (70.8%) male and 7 (28.8%) female patients. The mean age and mean weight during pacemaker implantation was 10.4 +/- 3.8 years (4-17 years) and 30 +/- I I kg (13.5-55 kg), respectively. The patients have been followed for 7-84 months (median 42 months). The percentage of atrial sensing-ventricular pacing changed from 75 to 99.9% at the last control. During the follow-up period, pacing mode was changed to VVIR due to complete loss of AV synchrony in five patients (21%). Four of them had underlying cardiac disease. In these patients loss of AV synchrony might be related to cardiac enlargement/abnormal cardiac anatomy or small atrial dipole-ventricular tip length. Despite the loss of AV synchrony in post surgical AV block or dilated cardiomyopathy, single-lead VDD pacing systems can be successfully used in children with complete AV block and normal sinus node function. Patients and lead selection should be taken into consideration for the maintenance of AV synchrony.

Adolescent↗

Heart rate variability and autonomic dysfunction in SSPE.

Autonomic nervous system involvement in subacute sclerosing panencephalitis was studied in 29 patients by analysis of heart rate variability and compared with a control group which consisted of 20 age- and sex-matched healthy subjects. Holter recordings for 24 hours were obtained, and all recordings were analyzed using time-domain parameters. The patients with subacute sclerosing panencephalitis were found to have significantly lower values of standard deviation of all normal sinus intervals and triangular index when compared with the control group. Of 23 patients who had regular follow-up, 15 died in a period ranging from 1 to 13 months. Twelve of these patients had heart rate variability parameters lower than normal, but no significant difference was observed between the heart rate variability values of patients who survived or died. Also, there was no association between brain magnetic resonance imaging findings and heart rate variability indices. It is concluded that patients with subacute sclerosing panencephalitis have autonomic dysfunction; and this was thought to be mainly due to central involvement.

Autonomic Nervous System↗

Tolmetin and salicylate therapy in acute rheumatic fever: Comparison of clinical efficacy and side-effects.

BACKGROUND: The arthritis of rheumatic fever is very responsive to treatment with salicylates, but there are many adverse reactions, especially hepatotoxicity, due to aspirin (acetylsalicylic acid) therapy. These side-effects change the course and duration of rheumatic fever. Other non-steroidal anti-inflammatory drugs may be equally effective, although no reports are available. METHODS: We studied 72 patients with rheumatic fever who were admitted to Dr Sami Ulus Children's Hospital between 1995 and 1999. Twenty patients with arthritis were treated with tolmetin (25 mg/kg per day; group I) and 52 patients with arthritis and/or mild carditis were put on aspirin therapy (75-100 mg/kg per day) for 4-6 weeks (group II). Arthritis had disappeared at the same time in both the aspirin and tolmetin groups (P = 0.675). RESULTS: The erythrocyte sedimentation rates of patients upon admission, at the first week and at the end of therapy were not different in the two groups (P > 0.05). No adverse effect of tolmetin therapy was observed, whereas side-effects of salicylate were observed in 19 patients (36.5%) in the aspirin group. Hepatotoxicity, gastric irritation and salicylism were found in 16, four and three patients, respectively. Renal toxicity and Reye syndrome were not demonstrated. Because of these side-effects of aspirin, therapy had to be stopped for 10-20 days and the duration of hospitalization in this group was lengthened unnecessarily. CONCLUSION: Tolmetin was safe and effective treatment for arthritic rheumatic fever patients without carditis. Tolmetin can be used particularly in patients who cannot tolerate aspirin.

Adolescent↗

Cardiac dysrhythmias after transcatheter closure of ASD with Amplatzer device.

Transcatheter closure of atrial septal defect (ASD) has been used as an alternative to open heart surgery. Although transcatheter closure of ASD with the Amplatzer septal occluder is a safe and feasible method in pediatric patients, there is little published data on arrhythmia analysis following transcatheter device closure of secundum ASD. We evaluated cardiac dysrhythmias with 24-hour ambulatory electrocardiographic (ECG) monitoring after transcatheter closure of ASD with Amplatzer device. A total of 85 consecutive patients with ASD underwent transcatheter closure of secundum ASD with Amplatzer device between October 1998 and December 2003. The study involved 65 of these patients assessed by 24-hour ambulatory ECG monitoring. Seven patients were evaluated a second time by 24-hour monitorization. During the procedure, transient complete atrioventricular (AV) block was seen in two patients. One of them returned to normal sinus rhythm in catheterization lab and the other returned to normal sinus rhythm in two hours. Transient junctional rhythm was observed in another patient during the device placement. Twenty-four hour ambulatory ECG monitoring was performed on all patients after a mean four-month period (1-12 months). Holter recordings demonstrated rare supraventricular extrasystole in two patients, rare ventricular premature beats in two patients, and intermittent sinus arrest with sinus pause lasting <1.5 seconds in one patient, for a total of five patients (7.6%). In conclusion, dysrhythmias after transcatheter device closure of secundum ASD with Amplatzer device are rare and benign. We need further long-term follow-up to evaluate late dysrhythmias after the transcatheter device closure of secundum ASD.

Adolescent↗