PubMed Health⌕ Search

Biomedical subjects

Cesar A Santana

Publications and source records attributed to Cesar A Santana.

5 recordsLinked to original sources

Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation.

UNLABELLED: Clinical decisions regarding diagnosis and effective treatment of coronary artery disease frequently require integration of information from various imaging modalities, which are acquired, processed, and read at different physical locations and times. We have developed methods to integrate the information in 2 cardiac imaging studies, perfusion SPECT and coronary angiography. Three-dimensional (3D) models of the coronary artery tree created from biplane angiograms were automatically aligned with 3D models of the left ventricular epicardial surface created from perfusion SPECT. Myocardial mass at risk was used as a unique measure to validate the accuracy of the unification. METHODS: Thirty patients were injected with the perfusion agent (99m)Tc-tetrosfosmin during balloon occlusion while undergoing percutaneous transluminal coronary angioplasty for single-vessel coronary artery disease. Thus, a single, severe perfusion defect was induced by a single coronary artery occlusion of known severity and placement. The accuracy of the unification was measured by computing the overlap between physiologic area at risk, determined using SPECT perfusion quantification techniques only, and anatomic area at risk, determined using coronary artery anatomy aligned with the epicardial surface of the left ventricle. RESULTS: The unification resulted in an 80% overlap of areas at risk, and an overlap of 84% of normal areas, for all coronary artery distributions. The mass at risk measured based on the unified anatomic information correlated with the physiologically based mass at risk as y = 0.92x + 10.3 g; r = 0.76, SEE = 10.4 g. CONCLUSION: A unification algorithm for automatically registering 3D models of the epicardial surface from perfusion SPECT and 3D coronary artery trees from coronary angiography has been presented and validated in 30 patient studies.

Algorithms↗

Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population.

BACKGROUND: A gender-independent stress normal database and criteria for abnormality for attenuation-corrected rest-stress technetium 99m sestamibi same-day myocardial perfusion imaging were developed by evaluation of 112 patients, validated against an obese population of 95 patients from four different clinical sites, and compared with conventional gender-matched database quantification of non-attenuation-corrected studies. METHODS AND RESULTS: These 95 validation patients (63 men) were used for prospective quantitative evaluation (mean weight, 213 +/- 57 lb; mean body mass index, 32 +/- 9 kg/m(2)). This group included 21 patients (12 men) with a lower than 5% likelihood of coronary artery disease (mean weight, 226 +/- 72 lb; mean body mass index, 34 +/- 13 kg/m(2)) and 74 who underwent cardiac catheterization within 2 months (35 with normal coronaries or coronary lesions <70%). These studies were processed twice, once by use of conventional reconstruction and gender-specific database quantification and a second time by use of attenuation correction and a single gender-independent attenuation-corrected normal database. The attenuation-corrected normal database and criteria for abnormality were developed by evaluation of 48 and 78 patients, respectively. No statistically significant differences were found when comparing attenuation-corrected perfusion distributions of normal men and women, whereas significant differences were found in the same uncorrected studies. Compared with quantitative analysis of the uncorrected studies, quantitative analysis of the attenuation-corrected studies by use of a gender-independent normal database demonstrated a significant improvement in normalcy rate (90% vs 52%, P =.006) and specificity (57% vs 29%, P =.015) in this obese population at no significant loss in sensitivity (90% vs 97%, P = not significant). CONCLUSION: Attenuation-corrected studies can be quantified with a single gender-independent normal database and a single criterion for abnormality without loss of sensitivity and with significantly better specificity and normalcy rate.

Coronary Artery Disease↗

Incremental prognostic value of left ventricular function by myocardial ECG-gated FDG PET imaging in patients with ischemic cardiomyopathy.

BACKGROUND: The purpose of this study was to determine the independent value of left ventricular (LV) functional parameters derived from gated fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) to predict prognosis in patients with ischemic cardiomyopathy undergoing myocardial viability assessment. METHODS AND RESULTS: We studied 90 consecutive patients with coronary artery disease and low LV ejection fraction (26% +/- 7%) undergoing gated FDG PET to assess myocardial viability for potential revascularization. The primary endpoint for this analysis was the occurrence of cardiac death, myocardial infarction, or worsening heart failure (HF) to New York Heart Association class IV. During follow-up (22 +/- 14 months), 21 patients had an event (17 died, 4 had myocardial infarctions, and 4 had worsening HF). On Cox regression analysis, the event-free survival rate at 2 years was lower for patients with an end-diastolic volume (EDV) of 260 mL or greater (relative risk, 2.7; P = .014), end-systolic volume (ESV) of 200 mL or greater (relative risk, 2.5; P = .021), and LV mass of 143 g or greater (relative risk, 1.6; P = .009). In a risk-adjusted model, EDV (chi 2 = 68, P < .0001) and ESV (chi 2 = 75, P = .035) added a significant amount in the estimation of events over the perfusion-FDG mismatch pattern (chi 2 = 40, P < .001). In a stratified Cox model, patients with PET mismatch, LV ejection fraction lower than 25%, and EDV of 260 mL or greater had the lowest survival rate (P = .006). These patients showed an apparent survival benefit with revascularization but without an improvement in HF symptoms. CONCLUSION: LV functional parameters determined by gated FDG PET have incremental prognostic value over viability information in patients with ischemic cardiomyopathy. Our data suggest that patients with residual viability and advanced cardiac remodeling are at high clinical risk. In these patients the apparent survival benefit of revascularization may not be associated with a measurable improvement in HF symptoms.

Cardiomyopathies↗

Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT.

BACKGROUND: The most widely distributed software packages to compute left ventricular (LV) volume and ejection fraction (EF) from gated perfusion tomograms are QGS and the Emory Cardiac Toolbox (ECTb). Because LV modeling and time sampling differ between the algorithms, it is necessary to document relationships between values produced by them and to establish normal limits individually for each software package in order to interpret results obtained for individual patients. METHODS AND RESULTS: Gated single photon emission computed tomography technetium 99m sestamibi myocardial perfusion studies were collected and analyzed for 246 patients evaluated for coronary artery disease. QGS and ECTb values of ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume were found to correlate linearly (r = 0.90, 0.91, and 0.94, respectively), but EF and EDV were significantly lower for QGS than with ECTb (53% +/- 13% vs 61% +/- 13 and 102 +/- 45 mL vs 114 +/- 50 mL, respectively). To compare calculations for healthy subjects between the two software packages, data were also selected for 50 other patients at low likelihood for coronary artery disease, for whom EF and EDV were significantly lower for QGS compared with ECTb (62% +/- 9% vs 67% +/- 8% and 84 +/- 26 mL vs 105 +/- 33 mL, respectively). The ECTb lower limit was 51% for EF and the upper limits were 171 mL for EDV and 59 mL/m(2) for mass-indexed EDV, compared with limits of 44%, 137 mL, and 47 mL/m(2) for QGS. CONCLUSIONS: Although correlations were strong between the two methods of computing LV functional values, statistical scatter was substantial and significant biases and trends observed. Therefore, when both software packages are used at the same site, it will be important to take these differences into consideration and to apply normal limits specific to each set of algorithms.

Adult↗