PubMed Health⌕ Search

Biomedical subjects

Chanbasha Basheer

Publications and source records attributed to Chanbasha Basheer.

At least 19 recordsLinked to original sources

On-site polymer-coated hollow fiber membrane microextraction and gas chromatography--mass spectrometry of polychlorinated biphenyls and polybrominated diphenyl ethers.

Porous polypropylene hollow fiber membrane coated with a conjugated polymer was used as an on-site sampling device for the extraction of polychlorinated biphenyls and polybrominated biphenyl ethers from coastal sea water samples. The coated hollow fiber membrane was placed in a vial containing the sample, and the target compounds extracted via manual shaking of the vials at the site of sample collection. For each extraction, two fibers were used. After extraction, the fibers with the adsorbed analytes were brought back to the laboratory for further processing. Care was taken to preserve the integrity of the analytes and to avoid contamination during transport; after extraction, the fibers were carefully removed and placed in air-tight crimper vials which were stored in an ice-box. The analytes were desorbed by solvent in the laboratory and analyses were carried out using gas chromatography/mass spectrometry. This method was highly reproducible with relative standard deviations in the range of 1-9%. Recoveries from spiked water samples ranged from 83% to 98%. Low limits of detections between 0.04 and 0.21ngl(-1) were achieved. The extraction efficiency was compared with solid-phase microextraction.

Gas Chromatography-Mass Spectrometry↗

Developments in single-drop microextraction.

Single-drop microextraction (SDME) has become a very popular liquid-phase microextraction technique because it is inexpensive, easy to operate and nearly solvent-free. Essentially, SDME combines extraction (and conceivably, cleanup) and concentration in a minimum number of steps, and thereafter, direct extract introduction into an analytical system. In this review, in order to encourage further development of SDME, we focus on its recent developments in its various guises. Its applications when used in combination with different analytical techniques, such as gas chromatography, high-performance liquid chromatography, inductively-coupled plasma mass spectrometry, capillary electrophoresis, mass spectrometry and electrothermal atomic absorption spectrometry, are summarized. SDME does have some limitations, and these are also discussed as well. Finally, an outlook on the future of the technique is given.

Analytic Sample Preparation Methods↗

Determination of trace level chemical warfare agents in water and slurry samples using hollow fibre-protected liquid-phase microextraction followed by gas chromatography-mass spectrometry.

A simple and solvent-minimised sample preparation technique based on hollow fibre-protected liquid-phase microextraction was investigated for the gas chromatography/mass spectrometric analysis of chemical warfare agents in water and slurry samples. The chemical warfare agents included four nerve agents and a blister agent. Parameters such as extraction solvent, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The technique provided a linear range of two orders of magnitude, good repeatability (RSDs < 10%, n = 6), good linearity (r2 >or= 0.995) and limits of detection (LODs) in the range of 0.02-0.09 microg l(-1) (S/N = 3) under full scan mode. The optimised technique was also applied to more complex slurry samples and similar precision (RSD < 15%, n = 3) and limits of detection (0.02-0.2 microgl(-1), S/N = 3) were obtained.

Chemical Warfare Agents↗

Polymer-coated hollow fiber microextraction combined with on-column stacking in capillary electrophoresis.

In this work, a novel microextraction method termed polymer-coated hollow fiber microextraction (PC-HFME) was developed in combination with capillary electrophoresis (CE). Polar dihydroxylated polymethylmethacrylate polymer was coated onto a porous propylene hollow fiber membrane and used as an adsorbent and that was placed in a stirred aqueous sample solution. Tumbling of the extraction device within the sample solution facilitated extraction. The amino alcohols (2-amino-1-phenylethanol, norephedrine, alprenolol and atenolol which are beta-blocker drugs), were used as model compounds to investigate the extraction performance. No organic solvent was used in this procedure. The extract was then further concentrated through on-column stacking (normal stacking mode) during CE analysis. The detection limits ranged from 0.9 to 7 ng ml(-1). Relative standard deviations (n=6) ranged from 4 to 6%. The extraction of the amino alcohols in spiked wastewater effluent (representing a complex matrix) was evaluated using the developed procedure.

Amino Alcohols↗

Development and application of porous membrane-protected carbon nanotube micro-solid-phase extraction combined with gas chromatography/mass spectrometry.

A novel, multiwalled carbon nanotube (MWCNT)-supported micro-solid-phase extraction (mu-SPE) procedure has been developed. A 6-mg sample of MWCNTs was packed inside a (2 cm x 1.5 cm) sheet of porous polypropylene membrane whose edges were heat-sealed to secure the contents. The mu-SPE device, which was wetted with dichloromethane, was then placed in a stirred sewage sludge sample solution to extract organophosporous pesticides, used here as model compounds. Tumbling of the extraction device within the sample solution facilitated extraction, and the porous membrane acted as a filter to exclude the extraction of extraneous materials. After extraction, analytes were desorbed in hexane and analyzed using gas chromatography/mass spectrometry. Since the porous membrane afforded protection of the MWCNTs, no further cleanup of the extract was required. The pi-pi electrostatic interaction with the analytes and the large surface area of MWCNTs facilitated the adsorption of analytes, with good selectivity and reproducibility. Under the optimized extraction conditions, the method showed good linearity in the range of 0.1-50 mug/L, repeatability of the extractions (RSD 2-8%, n = 4), and low limits of detection (1-7 pg/g). No analyte carryover effect was observed, and each mu-SPE device could be used for up to 30 extractions. Comparison was made with hollow fiber protected solid-phase microextraction and headspace solid-phase microextraction; mu-SPE was demonstrated to be a fast, accurate, and cost-effective pretreatment method for sewage sludge samples.

Journal Article↗

Polymer-coated hollow-fiber microextraction of estrogens in water samples with analysis by gas chromatography-mass spectrometry.

A novel sorbent, dihydroxylated polymethylmethacrylate (DHPMM), coated on hollow-fiber membrane, is used for the polymer-coated hollow-fiber microextraction of trace amounts of natural and synthetic estrogens, such as diethylstilbestrol, estrone, 17beta-estradiol and 17alpha-ethynylestradiol, in aqueous samples. In this procedure, estrogens were extracted using the functionalized polar DHPMM polymer with derivatization using N-methyl-N-(trimethylsilyl)trifluoroacetamide followed by gas chromatography-mass spectrometric analysis. The detection limits for estrogens in aqueous sample were between 0.03 and 0.8 ng l(-1) and the calibration curves were linear over the concentration range 0.05-10 microgl(-1) and had correlation coefficients of >0.994. The relative standard deviations (RSDs) were <15% (n = 3). This simple, accurate, sensitive and selective analytical method is applicable to the determination of trace amounts of estrogens in reservoir and potable water samples.

Chemical Fractionation↗

Sol-gel-coated oligomers as novel stationary phases for solid-phase microextraction.

Amphiphilic and hydrophilic oligomers were synthesized and coated on fused silica capillaries using a sol-gel technique. Sol-gel-coated capillaries were evaluated for the solid-phase microextraction and preconcentration of a wide variety of non-polar and polar analytes. Both types of coatings were stable under high temperature (up to 280 degrees C). The extraction efficiency of the sol-gel coatings was evaluated for the extraction of both non-polar and polar analytes, including organochlorine pesticides, triazine herbicides, estrogens and alkylphenols (APs) and bisphenol-A (BPA). Compared with commercially available solid-phase microextraction (SPME) adsorbents such as poly(dimethylsiloxane)divenylbenzene and polyacrylate, the new materials showed comparable selectivity and sensitivity towards both non-polar and polar analytes. The new coatings gave good linearity and detection limits. For example with triazines, a detection limit of <0.005 microl l(-1), precision from 5.0 to 11.0% (n = 6) and linearity of the calibration plots (0.5 to 50 microl l(-1)) were obtained. The sol-gel coated SPME capillaries were used for the determination of triazine herbicides in reservoir water samples collected in Singapore.

Estrogens↗

Determination of alkylphenols and bisphenol-A. A comparative investigation of functional polymer-coated membrane microextraction and solid-phase microextraction techniques.

A functional polymer (hydroxylated polymethacrylate) coated on porous polysulfone hollow fiber membrane (PS-HFM) was used as an adsorbent for the extraction of alkylphenols and bisphenol-A from seawater samples. Analyses of the extracts were performed using gas chromatography-mass spectrometry (GC-MS) after injection-port derivatization using bis(trimethylsilyl)trifluoroacetamide (BSTFA). We term the procedure as polymer-coated hollow fiber microextraction (PC-HFME). Owing to high porosity PS-HFM coated with hydroxylated polymer showed high extraction efficiency. Compared with solid-phase microextraction (SPME), PC-HFME showed good selectivity and sensitivity. Detection limits of alkylphenols and bisphenol-A ranged between 0.07 and 2.34 ng l(-1). The linearity range was from 0.01 to 15 microg l(-1) and the correlation coefficient (r) up to 0.997. The sensitivity and selectivity of the coated HFM could be potentially tuned by changing the characteristics of the coated hydroxylated polymer. The PC-HFME procedure was applied to the detection of alkylphenols and bisphenol-A in the coastal waters of Singapore.

Benzhydryl Compounds↗

Dynamic hollow fiber-supported headspace liquid-phase microextraction.

With the increasing concern over deteriorating environmental quality, the analysis of organic pollutants in air, water, and soil has become critically important. The development of simple, efficient, and inexpensive analytical sample pretreatment is crucial for monitoring and evaluating the environment. In this work, a dynamic hollow-fiber supported headspace liquid-phase microextraction (DHF-HS-LPME) approach was developed. In dynamic LPME, the extracting solvent is held within a hollow fiber, affixed to a syringe needle and immersed in the sample solution, and is moved to-and-fro by using a programmable syringe pump. The movement facilitates mass transfer from the sample to the solvent. Here, a similar approach was adopted, except that extraction was from the headspace rather than by direct immersion. Analysis of the extract was carried out by gas chromatography-mass spectrometry. The effect of sampling temperature, water, salt, dwelling time were investigated. Results indicated that this novel headspace microextraction method gave good analyte-enrichment factors, linear range, limits of detection and repeatability, all of which were evaluated by extracting PAHs from soil samples. This technique represents an inexpensive, convenient, fast and simple sample preparation of this class of semi-volatile organic compounds.

Chromatography, Liquid↗

Analysis of persistent organic pollutants in marine sediments using a novel microwave assisted solvent extraction and liquid-phase microextraction technique.

A simple and novel analytical method for quantifying persistent organic pollutants (POPs) in marine sediments has been developed using microwave assisted solvent extraction (MASE) and liquid-phase microextraction (LPME) using hollow fibre membrane (HFM). POPs studied included twelve organochlorine pesticides (OCP) and eight polychlorinated biphenyl (PCB) congeners. MASE was used for the extraction of POPs from 1 g of sediment using 10 ml of ultrapure water at 600 W for 20 min at 80 degrees C. The extract was subsequently subjected to a single step LPME-HFM cleanup and enrichment procedure. Recovery varied between 73 and 111% for OCPs; and 86-110% for PCBs, and exceeded levels achieved for conventional multi-step Soxhlet extraction coupled with solid-phase extraction. The method detection limit for each POP analyte ranged from 0.07 to 0.70 ng g(-1), and peak areas were proportional to analyte concentrations in the range of 5-500 ng g(-1). Relative standard deviations of less than 20% was obtained, based on triplicate sample analysis. The optimized technique was successfully applied to POP analysis of marine sediments collected from the northeastern and southwestern areas of Singapore's coastal environment.

Environmental Monitoring↗

Development and application of a simple capillary-microreactor for oxidation of glucose with a porous gold catalyst.

An efficient oxidation of glucose to gluconic acid was performed using a porous gold(0) catalyst in a low-cost microreactor designed from Pyrex glass capillary tubing; compared with the conventional synthesis procedure this novel approach of using a capillary-microreactor offers a convenient and highly efficient means to optimise reaction conditions and catalytic activities.

Journal Article↗

Analysis of endocrine disrupting alkylphenols, chlorophenols and bisphenol-A using hollow fiber-protected liquid-phase microextraction coupled with injection port-derivatization gas chromatography-mass spectrometry.

Liquid-phase microextraction (LPME) coupled with gas chromatography-mass spectrometry were used to determine alkylphenols (APs), chlorophenols (CPs) and bisphenol-A (BPA) in aqueous samples. APs, CPs and BPA are highly polar compounds and need to be derivatized before analysis by GC-MS. In this work, they were derivatized in the GC injection port with bis(trimethylsilyl)trifluoroacetamide (BSTFA). The analytes were extracted directly from 5 ml of sample solution using 5 microl of organic solvent though a porous polypropylene hollow fiber. The hollow fiber, filled with an immiscible organic solvent (ca. 5 microl), was immersed in the sample solution which was stirred during the 30-min extraction. An aliquot (2 microl) of the extract and 2 microl of BSTFA were then consecutively injected into the GC injection port. Extraction parameters such as extraction time, pH of sample, concentration of salt added, and stirring rate were optimised. The proposed LPME provided a good average enrichment factor of up to 162-fold, reproducibility ranging from 5.9 to 13.9% (n = 4), and good linearity (r2 = 0.995) for spiked water samples. The limits of detection (LODs) ranged between 0.005 and 0.015 microgl(-1) (S/N = 3) using GC-MS with selective ion monitoring and limits of quantification were in the range of 0.012-0.026 microg l(-1). A comparative study was performed between LPME, headspace solid-phase microextraction (HS-SPME) and liquid-liquid extraction (LLE). The results obtained suggested that hollow fiber LPME was a rapid, simple and efficient technique for APs, CPs and BPA, and provided a good alternative to SPME and LLE. Finally, the proposed method was applied to monitor Singapore coastal water samples.

Endocrine Glands↗

Hollow fiber membrane-protected solid-phase microextraction of triazine herbicides in bovine milk and sewage sludge samples.

A porous polypropylene hollow fiber membrane (HFM)-protected solid-phase microextraction (HFM-SPME) procedure in conjunction with gas chromatography/mass spectrometric analysis for use in the determination of triazine herbicides in bovine milk samples is described. A 65-microm polydimethylsiloxane-divinylbenzne (PDMS-DVB) SPME fiber was protected by an HFM. HFM-SPME experimental parameters such as fiber type, extraction time, extraction temperature and salt concentration were investigated and optimized. The relative standard deviations for the reproducibility of the optimized HFM-SPME method varied from 4.30 to 12.37%. The correlation coefficients of the calibration curves were between 0.9799 and 0.9965 across a concentration range of 0-200 microg l(-1). The method detection limits for triazines in bovine milk were in the range of 0.003-0.013 microg l(-1) and limits of quantification were in the range of 0.006-0.021 microg l(-1). The suitability of HFM-SPME was extended to the analysis of the herbicides in sewage sludge samples. The results demonstrate that HFM-SPME was an efficient pretreatment and enrichment procedure for complex matrices.

Animals↗

Development and application of polymer-coated hollow fiber membrane microextraction to the determination of organochlorine pesticides in water.

A novel extraction procedure coupled with gas chromatography-mass spectrometric detection for quantification of organochlorine pesticides (OCPs) in water is described. Amphiphilic polyhydroxylated polyparaphenylene (PH-PPP) was synthesized and coated on the surfaces of a porous polypropylene hollow fiber membrane (HFM). Due to the high porosity of the HFM, maximum active surface area to achieve high extraction efficiency is expected. The polymer-coated HFM was used for the extraction of 15 OCPs from water. The extraction efficiency was compared with emerging and established methods such as liquid-phase microextraction (LPME), solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) techniques. We term the current procedure as polymer-coated hollow fiber microextraction (PC-HFME). PC-HFME showed good selectivity and sensitivity. Detection limits for OCPs were in the range of 0.001-0.008 microg l(-1). The sensitivity and selectivity of the coated HFM could be adjusted by changing the characteristics of the coated PH-PPP film.

Hydrocarbons, Chlorinated↗

Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma.

This study investigated the feasibility of applying liquid-phase microextraction combined with gas chromatography-mass spectrometry (GC-MS) to determine polychlorinated biphenyls (PCBs) in blood plasma. An efficient and simple extraction technique has been developed for the enrichment of PCBs from human blood plasma samples using single-step liquid-phase microextraction (LPME) in conjunction with a hollow fibre membrane (HFM). An eight PCB congener mixture was spiked into 2.5 ml of blood plasma, and the solution was then adjusted to pH 10.5 with a salinity of 20% (w/v) prior to making the total volume to 5 ml with ultrapure water. The porous HFM, filled with 3 microl of organic solvent, was then immersed into the solution, which was continuously agitated at 700 rpm for 30 min. Extract (1 microl) containing the pre-concentrated analytes was then injected into a GC-MS without further pre-treatment. Using an optimised extraction procedure, a large enrichment factor of the analytes, i.e. up to 241-fold was achieved in 30 min. The procedure resulted in a relative standard deviation of < 11% (n = 6), and a linear calibration range from 2.5 to 150 microg/l (r > 0.999), and detection limits between 0.07 and 0.94 microg/l, respectively. To demonstrate the feasibility of the procedure, PCB concentrations were determined in actual blood samples collected from the local population in Singapore using the optimised LPME technique.

Gas Chromatography-Mass Spectrometry↗

Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry.

A simple and rapid liquid-phase microextraction (LPME) method using a hollow fiber membrane (HFM) in conjunction with gas chromatography-mass spectrometry (GC-MS) is presented for the quantitative determination of 16 polycyclic aromatic hydrocarbons (PAHs) and 12 organochlorine pesticides (OCPs) in rainwater samples. The LPME conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of hollow fiber exposure time, stirring rate, sample pH, and composition. Enrichment factors of more than 100 could be achieved within 35 min of extraction with relative standard deviations (R.S.D.s) 1.3-13.6% for PAHs and 1.7-13.8% for OCPs, respectively, over a wide range of analyte concentrations. Detection limits ranged from 0.002 to 0.047 microg l(-1) for PAHs, and from 0.013 to 0.059 microg l(-1) for OCPs, respectively. The newly developed LPME-GC-MS method has been validated for the analysis of PAHs and OCPs in rainwater samples. Extraction recoveries from spiked synthetic rainwater samples varied from 73 to 115% for PAHs and from 75 to 113% for OCPs, respectively. Real rainwater samples were analyzed using the optimized method. The concentrations of PAHs and OCPs in real rainwater samples were between 0.005-0.162, and 0.063 microg l(-1), respectively.

Gas Chromatography-Mass Spectrometry↗

Enhancement of plant-microbe interactions using a rhizosphere metabolomics-driven approach and its application in the removal of polychlorinated biphenyls.

Persistent organic pollutants, such as polychlorinated biphenyls (PCBs), are a global problem. We demonstrate enhanced depletion of PCBs using root-associated microbes, which can use plant secondary metabolites, such as phenylpropanoids. Using a "rhizosphere metabolomics" approach, we show that phenylpropanoids constitute 84% of the secondary metabolites exuded from Arabidopsis roots. Phenylpropanoid-utilizing microbes are more competitive and are able to grow at least 100-fold better than their auxotrophic mutants on roots of plants that are able to synthesize or overproduce phenylpropanoids, such as flavonoids. Better colonization of the phenylpropanoid-utilizing strain in a gnotobiotic system on the roots of flavonoid-producing plants leads to almost 90% removal of PCBs in a 28-d period. Our work complements previous approaches to engineer soil microbial populations based on opines produced by transgenic plants and used by microbes carrying opine metabolism genes. The current approach based on plant natural products can be applied to contaminated soils with pre-existing vegetation. This strategy is also likely to be applicable to improving the competitive abilities of biocontrol and biofertilization strains.

Arabidopsis↗