PubMed Health⌕ Search

Biomedical subjects

Chandra S Throckmorton

Publications and source records attributed to Chandra S Throckmorton.

2 recordsLinked to original sources

Acoustic model investigation of a multiple carrier frequency algorithm for encoding fine frequency structure: implications for cochlear implants.

Current cochlear implants provide frequency resolution through the number of channels. Improving resolution by increasing channels is limited by factors such as the physiological feasibility of increasing the number of electrodes, the inability to increase the number of channels for those already implanted, and the increased possibility of channel interactions reducing channel efficacy. Recent studies have suggested an alternative method: providing a continuum of pitch percepts for each channel based on the frequency content of that channel. This study seeks to determine the frequency resolution necessary for the highest performance gain, which may give some indication of the feasibility for implementation in implants. A discrete set of carrier frequencies, instead of a continuum, are evaluated using an acoustic model to measure speech recognition. Performance increased as the number of available frequencies increased, and substantive improvement was seen with as few as two frequencies per channel. The effect of variable frequency discrimination was also assessed, and the results suggest that frequency modulation can still provide benefits with poor frequency discrimination on some channels. These results suggest that if two or more discriminable frequencies per channel can be generated for cochlear implant subjects then an improvement in speech recognition may be possible.

Acoustics↗

The effect of channel interactions on speech recognition in cochlear implant subjects: predictions from an acoustic model.

Acoustic models that produce speech signals with information content similar to that provided to cochlear implant users provide a mechanism by which to investigate the effect of various implant-specific processing or hardware parameters independent of other complicating factors. This study compares speech recognition of normal-hearing subjects listening through normal and impaired acoustic models of cochlear implant speech processors. The channel interactions that were simulated to impair the model were based on psychophysical data measured from cochlear implant subjects and include pitch reversals, indiscriminable electrodes, and forward masking effects. In general, spectral interactions degraded speech recognition more than temporal interactions. These effects were frequency dependent with spectral interactions that affect lower-frequency information causing the greatest decrease in speech recognition, and interactions that affect higher-frequency information having the least impact. The results of this study indicate that channel interactions, quantified psychophysically, affect speech recognition to different degrees. Investigation of the effects that channel interactions have on speech recognition may guide future research whose goal is compensating for psychophysically measured channel interactions in cochlear implant subjects.

Acoustic Stimulation↗