Evaluation and quality control of personal nephelometers in indoor, outdoor and personal environments.

Personal nephelometers provide useful real-time measurements of airborne particulate matter (PM). Recent studies have applied this tool to assess personal exposures and related health effects. However, a thorough quality control (QC) procedure for data collected from such a device in a large-scale exposure assessment study is lacking. We have evaluated the performance of a personal nephelometer (personal DataRAM or pDR) in the field. We present here a series of post hoc QC procedures for improving the quality of the pDR data. The correlations and the ratios between the pDRs and the collocated gravimetric measurements were used as indices of the pDR data quality. The pDR was operated in four modes: passive (no pump), active (with personal sampling pumps), active with a heated inlet, and a humidistat. The pDRs were worn by 21 asthmatic children, placed at their residences indoors and outdoors, as well as at a central site. All fixed-site pDRs were collocated with Harvard Impactors for PM2.5 (HI2.5). By examining the differences between the time-weighted average concentrations calculated from the real-time pDRs' readings and recorded internally by the pDRs, we identified 9.1% of the pDRs' measurements suffered from negative drifts. By comparing the pDRs' daily base level with the HI2.5 measurements, we identified 5.7% of the pDRs' measurements suffered from positive drifts. High relative humidity (RH) affected outdoor pDR measurements, even when a heater was used. Results from a series of chamber experiments suggest that the heated air stream cooled significantly after leaving the heater and entering the pDR light-scattering chamber. An RH correction equation was applied to the pDR measurements to remove the RH effect. The final R2 values between the fixed-site pDRs and the collocated HI2.5 measurements ranged between 0.53 and 0.72. We concluded that with a carefully developed QC procedure, personal nephelometers can provide high-quality data for assessing PM exposures on subjects and at fixed locations. We also recommend that outdoor pDRs be operated in the active mode without a heater and that the RH effect be corrected with an RH correction equation.

Air Pollutants↗

Applying open-path FTIR with computed tomography to evaluate personal exposures. Part 1: simulation studies.

This paper presents the theoretical background and the numerical evaluation results obtained using computed tomography coupled with open-path Fourier transform infrared (CT-FTIR) measurements to estimate personal exposures. In this simulation study, we first tested the one-dimensional scenario with a five-beam segment geometry. A series of Gaussian plumes and the corresponding path-integrated concentrations (PICs) were simulated. The personal exposures were estimated as the average of the point estimates calculated from the workers' locations and the concentration profiles reconstructed from the Smooth Basis Function Minimization algorithm. It was found that the running-average PIC updating strategy has similar performance as the spline PIC updating strategy. However, the latter strategy gives delayed estimates of the workers' exposures since it requires additional measurements before and after the time period of interest. In the two-dimensional scenario, we simulated a series of single-mode bivariate Gaussian plumes with a nine-beam radial geometry. The average of the estimated exposures from the CT-FTIR approach was close to the average of the true exposures. The concordance correlation factors between the true and estimated exposures were reasonably good (between 0.50 and 0.58). This study demonstrated that the CT-FTIR approach is feasible for industrial hygiene monitoring.

Algorithms↗

Applying open-path FTIR with computed tomography to evaluate personal exposures. Part 2: experimental studies.

This paper presents the experimental evaluation results of using computed tomography coupled with OP-FTIR (CT-FTIR) measurement to estimate personal exposures. Experimental data were collected inside a ventilation chamber with a remote controlled robot as a surrogate for a real human. While the robot moved inside the chamber, a tracer gas (carbon monoxide) was released from a line source. A personal sampling device measured the true exposure on the robot. The estimated personal exposures were calculated from both the area sampling array data and the CT-FTIR measurements along with the information about the robot's locations in real time. The location information was obtained by applying image analysis on recorded digital videotapes. The average slopes of the regression lines between the true and estimated exposures was 0.76 with 1 included in the 95% confidence interval. The concordance correlation factor (CCF) between the true and the CT-FTIR estimated exposures was 0.52, which was similar to the findings from previous simulation studies. Kriging the area sampling array data with an exponential algorithm instead of a liner algorithm improved the CCF value from 0.60 to 0.75. This suggests that using a different basis function for the SBFM algorithm might improve the performance of our estimation approach. Based on the sensitivity and specificity analysis of the experimental data, we demonstrated that this approach is suitable as a warning system.

Algorithms↗

Association of FEV1 in asthmatic children with personal and microenvironmental exposure to airborne particulate matter.

Exposure to particulate matter (PM) air pollution has been shown to exacerbate children's asthma, but the exposure sources and temporal characteristics are still under study. Children's exposure to PM is likely to involve both combustion-related ambient PM and PM related to a child's activity in various indoor and outdoor microenvironments. Among 19 children with asthma, 9-17 years of age, we examined the relationship of temporal changes in percent predicted forced expiratory volume in 1 sec (FEV1) to personal continuous PM exposure and to 24-hr average gravimetric PM mass measured at home and central sites. Subjects were followed for 2 weeks during either the fall of 1999 or the spring of 2000, in a southern California region affected by transported air pollution. FEV(subscript)1(/subscript) was measured by subjects in the morning, afternoon, and evening. Exposure measurements included continuous PM using a passive nephelometer carried by subjects; indoor, outdoor home, and central-site 24-hr gravimetric PM2.5 (PM of aerodynamic diameter < 2.5 microm) and PM10; and central-site hourly PM10, nitrogen dioxide, and ozone. Data were analyzed with linear mixed models controlling for within-subject autocorrelation, FEV1 maneuver time, and exposure period. We found inverse associations of FEV1 with increasing PM exposure during the 24 hr before the FEV1 maneuver and with increasing multiday PM averages. Deficits in percent predicted FEV1 (95% confidence interval) for given PM interquartile ranges measured during the preceding 24-hr were as follows: 128 microg/m3 1-hr maximum personal PM, -6.0% (-10.5 to -1.4); 30 microg/m3 24-hr average personal PM, -5.9% (-10.8 to -1.0); 6.7 microg/m3 indoor home PM2.5, -1.6% (-2.8 to -0.4); 16 microg/m3 indoor home PM10, -2.1% (-3.7 to -0.4); 7.1 microg/m3 outdoor home PM2.5, -1.1% (-2.4 to 0.1); and 7.5 microg/m3 central-site PM2.5, -0.7% (-1.9 to 0.4). Stronger associations were found for multiday moving averages of PM for both personal and stationary-site PM. Stronger associations with personal PM were found in boys allergic to indoor allergens. FEV1 was weakly associated with NO2 but not with O3. Results suggest mixed respiratory effects of PM in asthmatic children from both ambient background exposures and personal exposures in various microenvironments.

Adolescent↗

Applying open-path FTIR with a bi-beam strategy to evaluate personal exposure in indoor environments: experimental results of a validation study.

This study evaluated the performance and feasibility of using open-path Fourier transform infrared (OP-FTIR) with a bi-beam strategy to assess personal exposures in workplaces. The bi-beam strategy combines a long beam and a short beam measurement to calculate the average concentration level of the segmented region. A series of experiments was conducted with six human subjects at two workstations inside a chamber. A bi-beam geometry was set up for each workstation. Each subject repeatedly performed two tasks (9 min/task), which were designed to simulate a painting and an assembly task. For each task a tracer gas (N(2)O) was released from a point source near the subject. During each task, while the OP-FTIR collected the N(2)O spectrum, bag samples were collected simultaneously at nose and lapel height. Statistical data analysis applied a general linear model with the bag samples as the dependent variable. Results show that the locations, tasks, and subjects are not significant factors when using OP-FTIR measurements with the bi-beam strategy to estimate personal exposure at the nose height. The model used in this study fits the data reasonably well (R(2)=0.87), and when it is compared with a second set of experimental data, the bias is 0.7 ppm (3%) and the precision is 5.5 ppm. This study demonstrates that the bi-beam sampling strategy may offer a new approach for applying OP-FTIR to industrial hygiene monitoring.

Air Pollution, Indoor↗