PubMed Health⌕ Search

Biomedical subjects

Charles A Lucy

Publications and source records attributed to Charles A Lucy.

At least 19 recordsLinked to original sources

Fast and high-resolution ion chromatography at high pH on short columns packed with 1.8 microm surfactant coated silica reverse-phase particles.

Rapid ion chromatographic separations of small inorganic anions are performed on columns packed with high-pH resistant Zorbax Extend-C18 1.8 microm silica particles. Seven anions (iodate, chloride, nitrite, bromide, nitrate, phosphate, sulphate) are separated with 1.3 and 2 cm long x 0.46 cm I.D. C18 columns coated with the surfactant didodecyldimethylammonium bromide (DDAB). A 40 s separation is achieved at 2 mL/min with a 2.5 mM 4-hydroxybenzoic acid eluent at pH 10. Finally, the DDAB removal procedure is improved to eliminate the pressure build-up caused by precipitation of the surfactant in the column upon uncoating.

Anions↗

Highly efficient protein separations in capillary electrophoresis using a supported bilayer/diblock copolymer coating.

A surfactant/polymer wall coating consisting of the doubly chained cationic surfactant dimethyldioctadecylammonium bromide (DODAB) and polyoxyethylene (POE) 40 stearate is investigated. The coating is formed by simply rinsing a capillary with a solution containing DODAB and POE 40 stearate. The resultant coating is semi-permanent--demonstrating stable electroosmotic flow (EOF) even after a 60 min high pressure rinse with buffer. The EOF (-0.45+/-(0.23) x 10(-4) cm(2) V(-1) s(-1) at pH 7.4) is suppressed by more than a factor of ten compared to that observed for DODAB alone. Model protein mixtures were separated over a pH range of 3-10 with efficiencies of up to greater than 1 million plates/m for the basic proteins cytochrome c, lysozyme, ribonuclease A and alpha-lactalbumin, and the acidic proteins insulin chain A, trypsin inhibitor, and alpha-chymotrypsinogen A. Migration time reproducibility was 0.5-4.0% from run to run and 0.6-4.3% from day to day. Protein recoveries with this coating ranged from 84% to 97%.

Electrophoresis, Capillary↗

Achieving rapid low-pressure ion chromatography separations on short silica-based monolithic columns.

Short silica-based monolithic columns (0.5-1 cm) are coated with the surfactant didodecyldimethylammonium bromide (DDAB) and used for fast ion exchange separations of small inorganic anions. Sources of extra-column band broadening are assessed and minimized to obtain separations of seven analytes (iodate, chloride, nitrate, bromide, nitrite, phosphate, sulphate) in two minutes at 2 mL/min. Eluents used are 6 and 9 mM 4-cyanophenol at pH 7.3-7.4 or 5 mM 4-hydroxybenzoic acid at pH 5.6. DDAB coating stability is improved by 15-fold by the addition of a DDAB coated pre-column before the injection valve. Separations are obtained using a low-pressure glass syringe.

Air Pressure↗

Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence.

Fluorescence detectors are ever more frequently being used with light-emitting diodes (LEDs) as the light source. Technological advances in the solid-state lighting industry have produced LEDs which are also suitable tools in analytical measurements. LEDs are now available which deliver 700 mW of radiometric power. While this greater light power can increase the fluorescence signal, it is not trivial to make proper use of this light. This new generation of LEDs has a large emitting area and a highly divergent beam. This presents a classic problem in optics where one must choose between either a small focused light spot, or high light collection efficiency. We have selected for light collection efficiency, which yields a light spot somewhat larger than the emitting area of the LED. This light is focused onto a flow cell. Increasing the detector cell internal diameter (i.d.) produces gains in (sensitivity)3. However, since the detector cell i.d. is smaller than the LED spot size, scattering of excitation light towards the detector remains a significant source of background signal. This can be minimized through the use of spectral filters and spatial filters in the form of pinholes. The detector produced a limit of detection (LOD) of 3 pM, which is roughly three orders of magnitude lower than other reports of LED-based fluorescence detectors. Furthermore, this LOD comes within a factor of six of much more expensive laser-based fluorescence systems. This detector has been used to monitor a separation from a gel filtration column of fluorescently labeled BSA from residual labeling reagent. The LOD of fluorescently labeled BSA is 25 pM.

Journal Article↗

Sulfonium and phosphonium, new ion-pairing agents with unique selectivity towards polarizable anions.

Ion-pair chromatography (IPC) almost universally relies upon ammonium-based ion-pairing agents (IPAs) for anion separations. This work compares tetrabutylammonium (TBA) with tetrabutylphosphonium (TBP) and tributylsulfonium (TBS). To best understand the retention behavior analytes used for characterization of the IPAs spanned the Hofmeister series; from kosmotropic monoanions (iodate, chloride, nitrite) and intermediate anions (nitrate, bromide) to chaotropic ions (perchlorate, thiocyanate, iodide). The studies demonstrate that tetrabutylphosphonium is the most chaotropic IPA, followed by tetrabutylammonium and finally tributylsulfonium is the least chaotropic. In the case of the chaotropic anions, the retention of perchlorate was least with tributylsulfonium, and greatest for tetrabutylphosphonium, with tetrabutylammonium being intermediate. The multivalent kosmotropic anions (sulfate, chromate, thiosulfate) demonstrated unique selectivity changes depending on the kosmotropic/chaotropic nature of the IPA. Demonstrating increases in retention with increasing IPA concentration only with tributylsulfonium, whereas the more chaotropic IPAs universally decreased the retention of the multivalent anions.

Anions↗

Fast supercritical fluid chromatography hydrocarbon group-type separations of diesel fuels using packed and monolithic columns.

Two approaches for decreasing diesel hydrocarbon group-type separation times by normal phase supercritical fluid chromatography (SFC) are compared. Short (10-15 cm) columns with small 3 microm diameter packing are compared with monolithic Chromolith bare silica columns under high carbon dioxide flow rates approaching 5 ml min(-1). Elution times are reduced up to 13-fold on a 10 cm Chromolith column and 7-fold on the short packed columns compared with conventional length columns run at typical flow rates. Short packed columns, with their higher surface area and retention characteristics, offer higher resolutions compared with Chromolith columns. Diesel samples are separated into saturates, mono-, di-, tri-, and polyaromatics in as little as 2 min on a 10 cm packed silica column. Diesel group-type results on a 15 cm titania-silica coupled column compare favorably with results from longer columns.

Chromatography, Supercritical Fluid↗

Preparative capillary zone electrophoresis using a dynamic coated wide-bore capillary.

Preparative capillary zone electrophoresis separations of cytochrome c from bovine and horse heart are performed efficiently in a surfactant-coated capillary. The surfactant, dimethylditetradecylammonium bromide (2C(14)DAB), effectively eliminated protein adsorption from the capillary surface, such that symmetrical peaks with efficiencies of 0.7 million plates/m were observed in 50-microm id capillaries when low concentrations of protein were injected. At protein concentrations greater than 1 g/L, electromigration dispersion became the dominant source of band broadening and the peak shape distorted to triangular fronting. Matching of the mobility of the buffer co-ion to that of the cytochrome c resulted in dramatic improvements in the efficiency and peak shape. Using 100 mM bis(2-hydroxyethyl)imino-tris(hydroxymethyl)methane phosphate buffer at pH 7.0 with a 100-microm id capillary, the maximum sample loading capacity in a single run was 160 pmol (2.0 microg) of each protein.

Buffers↗

Comparison of titania, zirconia, and silica stationary phases for separating diesel fuels according to hydrocarbon group-type by supercritical fluid chromatography.

Silica, zirconia, and titania columns were compared for their ability to separate diesel samples into saturates, mono-, di-, tri-, and polyaromatics by supercritical fluid chromatography (SFC) using pure CO(2) according to ASTM method D 5186-03. A titania column coupled in series to a silica column was found to provide the highest overall group-type resolutions based on 20 model compounds, with resolutions as high as 14.7 for saturates versus monoaromatics and 11.9 for monoaromatics versus diaromatics. An oilsands-derived Synfuel light diesel, a commercial Ontario diesel, and a heavy Shell Canada Ltd. diesel blending feedstock were studied on a titania-silica coupled column as well as on a conventional silica column. The Synfuel results were similar (within 0.5 mass%) on both the conventional bare silica column and the titania-silica coupled column. The heavier commercial diesel and diesel blending feedstock samples yielded different results on the titania-silica coupled column compared to the silica column alone, demonstrating the importance of achieving the highest possible resolutions when baseline separation of group-types is not obtained.

Chromatography, Supercritical Fluid↗

Study of the selectivity of inorganic anions in hydro-organic solvents using indirect capillary electrophoresis.

In capillary electrophoresis (CE) analysis of small inorganic anions, the ability to control the electroosmotic flow (EOF) and the ability to alter the electrophoretic mobility of the ions are essential to improve resolution and separation speed. In this work, a CE method for separation of small inorganic anions using indirect detection in mixed methanol/water buffers is presented. The suitability of different UV absorbing probes commonly used for indirect detection including chromate, iodide, phthalate, benzoate, trimellitate, and pyromellitate, in mixed methanol/water buffers is examined. The effect of the electrolyte buffer system, including the pH, buffer concentration and the organic solvent on the electrophoretic mobility of the probes and analytes are also investigated. The EOF was reversed using cationic surfactant, cetyltrimethylammonium bromide (CTAB) so ions were separated under co-EOF mode. The organic solvent alters the electrophoretic mobility of the probes and the analytes differently and hence choice of the appropriate probe is essential to achieve high degree of detection sensitivity. Separations of six anions in less than 2.5 min were accomplished in buffers containing up to 30% MeOH. Adjustment of the methanol content helps to improve the selectivity and resolution of inorganic anions. Limit of detection, reproducibility and application of the method for quantification of anions in water samples will also be discussed.

Anions↗

Effect of anionic additive type on ion pair formation constants of basic pharmaceuticals.

Due to their beneficial effect on selectivity, peak shape, and sample loading, the use of mobile phase anionic additives, such as formate (HCOO-), chloride (Cl-), and trifluoroacetate (CF3COO-), is increasing in both reversed-phase chromatography (RPLC) and liquid chromatography-mass spectrometry (LC/MS). Similarly, perchlorate is a common "ion pair" agent in reversed-phase separation of peptides. Although many studies have suggested that anions effect in chromatography is due to the formation of ion pairs in the mobile phase between the anions and cationic analytes, there has been no independent verification that ion pairs are, in fact, responsible for these observations. In order to understand the mechanisms by which anionic additives influence retention in chromatography and ionization efficiency in electrospray mass spectrometry, we studied the formation of ion pairs between a number of prototypical basic drugs and various additives by measuring the effect of anionic additives on the electrophoretic mobility of the probe drugs under solvent conditions commonly used in chromatography. For the first time, ion pair formation between basic drugs and anionic additives under conditions commonly used in reversed-phase liquid chromatography has been confirmed independently with all anions (i.e. hexafluorophosphate, perchlorate, trifluoroacetate, and chloride) used in this study. We measured ion pair formation constants (Kip) for different anionic additives using capillary electrophoresis (CE) and obtained quantitative estimates for the extent of ion pairing in buffered acetonitrile-water. The data clearly indicate that different anionic additives ion pair with cationic drugs to quite different extents. The ion pair formation constants show a clear trend with the order being: PF6- > ClO4- > CF3COO- > Cl-. However, the extent of ion pairing is not large. At a typical RPLC mobile phase additive concentration of 20mM, the percentages of the analytes that are present as ion pairs are about 15%, 6%, and 3% for hexafluorophosphate, perchlorate, and trifluoroacetate, respectively. The fraction of the analytes present as a chloride pair is even smaller.

Amitriptyline↗

Oligomerized phospholipid bilayers as semipermanent coatings in capillary electrophoresis.

Double-chained surfactants form semipermanent coatings that prevent protein adsorption in capillary electrophoresis (CE). To make such coatings more permanent, vesicles of the unsaturated phospholipid 1,2-dioleoyl-sn-glycero-3-phosphocholine were prepared and subjected to free-radical-initiated polymerization, both inside the capillary and in free solution. The latter generated oligomers of 2-5 units based on ESI-TOF MS, and formed the more stable coating in CE. Rinsing the capillary with a solution of the ex situ oligomerized DOPC suppressed EOF (0.8 x 10(-)(8) m(2)/V.s) for more than 20 h, whereas in situ oligomerized electroosmotic flow (EOF) suppressed the EOF for only 10 h. Mixtures of anionic and cationic proteins were separated under neutral pH and low ionic strength buffer with efficiencies of 480,000-930,000 plates/m and recoveries of 75-99%.

Electrophoresis, Capillary↗

Enhanced stability self-assembled coatings for protein separations by capillary zone electrophoresis through the use of long-chained surfactants.

Semipermanent coatings were generated within fused-silica capillaries by flushing the capillary with a 0.1 mM solution of the double-chained cationic surfactants didodecyldimethylammonium bromide, dimethylditetradecylammonium bromide (2C(14)DAB), dihexadecyldimethylammonium bromide, and dimethyldioctadecylammonium bromide (2C(18)DAB) and the triple-chained surfactant tridodecylmethylammonium iodide. All of these coatings were semipermanent, whereby the coating remained intact after the unadsorbed surfactant was removed from the capillary. The separation efficiencies for four model cationic proteins ranged from 1.2 to 1.4 million plates/m for the 2C(14)DAB coating to 0.3-0.4 million plates/m for the 2C(18)DAB coatings. The stability of the coating increased with increasing hydrophobicity of the surfactant (i.e., increasing chain length and decreasing cmc). Over 60 successive separations were performed on a 2C(18)DAB-coated capillary over 12 days, without any regeneration of the coating. The migration times varied by less than 2.3% over this period with no loss in efficiency.

Electroosmosis↗

Enhancement of electroosmotic flow using zwitterionic additives.

Zwitterionic additives provide a means of altering the EOF without increasing conductivity. The magnitude of the EOF in a bare silica capillary increased by as much as 69% upon addition of 500 mM of zwitterion to the running buffer. The EOF enhancement increases linearly with the zwitterion concentration. With zwitterionic additives of the form +NH3-(CH2)n-COO-, the magnitude of the EOF increase is directly related to the number of methylene groups, (n), which ranges from n = 1 to 7. The endgroups on the zwitterions also affect the EOF enhancement. The effect of Z1-methyl (+N(CH3)3CH2CH2CH2SO3-) on EOF was not a function of either the buffer cation or pH. The EOF enhancement is a function of the dielectric increment of the additive and the nature of the amine functionality.

Amino Acids↗

HPLC simultaneous analysis of thiols and disulfides: on-line reduction and indirect fluorescence detection without derivatization.

A liquid chromatography method with indirect fluorescence detection has been developed for simultaneous detection of cysteine, cystine, homocysteine, homocystine, glutathione and glutathione disulfide. After separation in their native forms, a post-column solution of tris(2-carboxyethyl)phosphine (TCEP) at 32 mM, pH 8 is added to reduce the disulfides on-line to the corresponding thiol. The effluent is then merged with a second post-column solution of the highly fluorescent complex Cd(HQS)(2)(2-). The cadmium is complexed by the eluting thiols, effectively quenching the fluorescence. Optimization of the separation, the on-line reduction and the indirect fluorescence detection are discussed. Detection limits from 0.3-4.3 microM (0.04 to 2.6 ppm) are achieved for the six analytes in a 20 min separation.

Journal Article↗

Factors affecting the temporal stability of semipermanent bilayer coatings in capillary electrophoresis prepared using double-chained surfactants.

Surfactants such as didodecyldimethylammonium bromide (DDAB) adsorb onto fused-silica capillaries to form semipermanent bilayer coatings. However, such coatings must be regenerated between runs to maintain efficiency and reproducibility. In this paper, chemical and physical factors affecting the stability of DDAB coatings are investigated. Chemical factors such as ionic strength and the nature of the buffer anion (e.g., from acetate to phosphate), which decrease the critical micelle concentration of DDAB, improve the coating stability. Increasing buffer pH also increases the coating stability. Finally, reducing the capillary diameter and reducing the volume of buffer flushed through the capillary enhance the coating stability. Using 50 mM acetate, pH 5.0, in a 25-microm-i.d. capillary, cationic proteins were separated with efficiencies of 1.05 million plates/m and a run-to-run migration time reproducibility of 0.6-0.8% RSD for 10 successive runs without regeneration of the DDAB coating between runs.

Journal Article↗

Electroosmotic flow reversal for the determination of inorganic anions by capillary electrophoresis with methanol-water buffers.

Manipulation of the electroosmotic flow (EOF) is essential for achieving optimized separations of small anions by capillary electrophoresis (CE). In this work, efficient suppression or reversal of EOF is achieved upon addition of small amounts of the cationic surfactants, cetyltrimethylammonium bromide (CTAB) or didodecyldimethylammonium bromide (DDAB) to the electrophoretic buffer. Highly stable and reversed EOF are achieved using the surfactants in the presence of up to 50% MeOH. In aqueous and low methanol containing solutions (up to 30%, v/v) surface aggregation of the surfactants at the capillary wall occurs at a concentration below the critical micelle concentration (CMC). The impact of MeOH on reversed EOF is predominantly a function of the diminished zeta potential of the silica, and to a lesser extent on the CMC in the bulk solution of the surfactant. Fast baseline separation and selectivity changes for small inorganic anions are observed when mixed aqueous-organic buffers are employed. Changes in EOF, micellar properties of the surfactant and selectivity for inorganic anions upon addition of various percent of methanol are also discussed.

Anions↗

Mixed cationic/anionic surfactants for semipermanent wall coatings in capillary electrophoresis.

Mixtures of the cationic surfactant cetyltrimethylammonium bromide (CTAB) with the anionic surfactant sodium dodecyl sulfate (SDS) form more stable coatings in fused-silica capillaries than CTAB alone. The reversed electroosmotic flow (EOF) generated by CTAB/SDS mixtures remains stable for over 80 min after removal of the surfactants from the buffer. Enhanced stability (relative to CTAB alone) was found even when the ratio of SDS to CTAB was as low as 1%. This greater coating stability is attributed to the structural transition from adsorbed micelle to bilayer, which is induced by addition of SDS. Separation of a mixture of basic proteins yielded efficiencies of 364 000-562 000 plates/m and recoveries ranging from 85% to 98%. Migration time reproducibility was less than 0.9% relative standard deviation (RSD) from run to run and less than 2.6% RSD from day to day.

Anions↗

Noncovalent labeling of myoglobin for capillary electrophoresis with laser-induced fluorescence detection by reconstitution with a fluorescent porphyrin.

Traditional protein labeling reactions for capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection suffer from a variety of disadvantages. The reactions can be nonquantitative on a reasonable time scale, require relatively high concentrations of protein and fluorophore, and can give multiple reaction products that can not be separated. Herein, we describe a new noncovalent labeling technique that is rapid, selective for myoglobin, and gives a simple reaction product. Myoglobin is denatured with either 5.4 M urea or low pH (2.0). The denatured myoglobin releases its nonfluorescent heme group. A fluorescent porphyrin (protoporphyrin IX (PPIX) or its zinc (II) complex, Zn-PPIX), is added to the mixture and the solution conditions are altered (dilute to 0.54 M urea or adjust pH to 7.0) to allow myoglobin refolding. Upon refolding, the protein incorporates PPIX from solution, thus making the reaction product fluorescent. The experimental conditions have been optimized for both urea and low-pH denaturation of myoglobin. The latter procedure produces a detection limit of 50 nM. Alternatively, the reaction can be performed without denaturation by a simple exchange of the porphyrins. The use of Zn-PPIX yields the most efficient reaction. The low-pH reaction is unaffected by a 2000-fold excess of bovine serum albumin.

Electrophoresis, Capillary↗