The effect of sodium profiling and feedback technologies on plasma conductivity and ionic mass balance: a study in hypotension-prone dialysis patients.

BACKGROUND: Sodium profiling improves haemodynamic tolerance in haemodialysis (HD) patients but may also influence sodium homeostasis. Changes in blood volume and plasma conductivity (PC) during HD can be modelled by feedback technology, but their effects on sodium homeostasis are not widely studied. METHODS: This randomized crossover study compared PC and ionic mass balance (IMB) as surrogate markers of sodium balance between standard HD [dialysate conductivity (DC) 14.0 mS/cm], sodium profiling (DC 15.0-->14.0 mS/cm), blood volume (BV)-controlled and PC-controlled feedback (target: post-HD PC: 14.0 mS/cm) in 10 HD patients with frequent hypotension. RESULTS: 440 treatments were studied. Pre-dialytic PC was significantly higher during SP (14.4+/-0.2 mS/cm) compared to standard HD (14.2+/-0.3 mS/cm), and was not different between the other manoeuvres: PC-controlled (14.1+/-0.3 mS/cm), and BV-controlled feedback (14.2+/-0.2 mS/cm). Except for the first treatment, during which IMB was lower during the sodium profile, IMB did not differ significantly between the various manoeuvres and was strongly dependent upon ultrafiltration volume and the difference between pre-dialytic PC and DC. Symptomatic hypotensive episodes occurred least frequently during BV-controlled feedback (8%) compared to the other manoeuvres (standard HD, 16%; sodium profile, 14%; PC-controlled feedback, 17%), but differences were not significant. Inter-dialytic weight gain and pre-dialytic systolic blood pressure did not differ. CONCLUSIONS: Pre-dialytic PC increased during the sodium profile, and did not differ between BV- or PC-controlled feedback compared to standard HD. Thus, it appears that both BV- and PC-controlled feedback can be safely prescribed without substantial salt- and water-loading, at least in the short term. Analysis of IMB is useful to assess differences in sodium balance between single treatment sessions but appears of less value in a steady-state situation.

Aged↗

Haemodynamics and electrolyte balance: a comparison between on-line pre-dilution haemofiltration and haemodialysis.

BACKGROUND: An important advantage of convective therapies is improved vascular reactivity. However, it is not well known whether the vascular response during convective therapies remains superior when compared to haemodialysis (HD) with an adjusted temperature of the dialysate. It has also been suggested that convective therapies may impair small electrolyte removal through an effect on the Donnan equilibrium. In the present study, we compared the haemodynamic response and small electrolyte removal between pre-dilution on-line haemofiltration (HF) and HD procedures. METHODS: Cardiac output (CO), central blood volume (CBV) and peripheral vascular resistance (PVR) were assessed, using the saline dilution technique, in 12 stable patients during HF and HD with two different temperatures of the dialysate [36.5 and 35.5 degrees C (HD(36.5) and HD(35.5))]. Balances for sodium, potassium, calcium and conductivity were assessed using total dialysate/filtrate collections. Target filtration volume for HF was 1.2 times body weight. The temperature of the infusate was 36.5 degrees C. RESULTS: The change (Delta) in CBV was less during HD with a dialysate temperature of 35.5 degrees C (-0.03+/-0.14 l; P<0.05) compared to HF (-0.16+/-0.05 l) and HD(36.5) (-0.11+/-0.14 l), but the other haemodynamic parameters did not differ between the studied techniques. DeltaPVR was significantly related to DeltaCBV (r = -0.46; P<0.01), whereas DeltaCBV was related to ultrafiltration rate (r = -0.34; P = 0.05). DeltaCO was related to DeltaCBV (r = 0.62; P<0.001). Solute balances did not differ between HF and HD. CONCLUSION: Using the saline dilution method, no difference in the change in CO and PVR was observed between on-line HF vs HD(36.5) and HD(35.5). Only CBV declined to a significantly lesser degree during HD(35.5), although absolute differences were small. Changes in the other haemodynamic variables appeared more dependent upon the degree and rapidity of fluid removal than upon the treatment modality. No difference in small electrolyte balance was observed between HF and HD, suggesting that ionic removal is not impaired during on-line HF.

Aged↗

Reference values for multifrequency bioimpedance analysis in dialysis patients.

BACKGROUND: The role of multifrequency bioimpedance(MF-BIA) in the assessment of fluid status in dialysis patients is still not fully elucidated. Especially, the predictive value of reference values for extracellular water (ECW) has not yet been addressed. Aim of the present study was to validate cut-off values for MF-BIA in the diagnosis of hypervolemia in dialysis patients, using strict clinical criteria and echocardiography as reference techniques. METHODS: 90 patients [42 on hemodialysis; 48 on peritoneal dialysis] were divided into the following groups: clinically normovolemic (mean 24- or 48-hour systolic blood pressure below 133 mm Hg without use of antihypertensive agents; n = 12), 'hypervolemic' (mean systolic blood pressure above 133 mm Hg with 2 or more antihypertensive agents; n = 34) or undetermined (n = 44). The 80th percentile for normalized ECW in the clinically normovolemic patients was used as reference value. 20 healthy age-matched controls were included for comparison. RESULTS: The 80th percentiles for ECW:body weight (BW) and ECW:height in 'normovolemic' subjects were, respectively, 0.245 liters/kg and 10.96 liters/m in males, and 0.232 liters/kg and 9.13 liters/m in females. ECW:BW and ECW:height were above these values in, respectively, 26 (sensitivity 76%) and 29 (sensitivity 86%) of the 34 'hypervolemic' patients. In the undetermined group, left ventricular end-diastolic diameter was significantly different between patients with normalized ECW below and above these cut-off values (49.0 +/- 5.1 vs. 52.4 +/- 5.7 mm; p < 0.05). Use of the ECW:TBW ratio resulted yielded low sensitivity (45%). ECW:height was lower in the 'normovolemic' dialysis patients compared to healthy controls (9.7 +/- 1.3 l/m versus 12.2 +/- 1.9 l/m). CONCLUSION: In our study population, ECW by MF-BIA, normalized for height was able to predict hypervolemia, based on strict clinical criteria, with a sensitivity of 86% and a specificity of 80%. The normalization procedure for ECW may influence the classification of hydration status. Strictly normotensive dialysis patients had lower normalized ECW than healthy control subjects.

Adult↗

A comparison between the soluble transferrin receptor, transferrin saturation and serum ferritin as markers of iron state in hemodialysis patients.

An adequate iron management is important in the treatment of anemia and in hemodialysis (HD) patients. Serum ferritin and transferrin saturation (TS) may be influenced by the presence of inflammation. Recently, the soluble transferrin receptor (s-TfR) has been advocated as a parameter of iron status in HD patients. The aim of the present study was to assess firstly the relation between serum ferritin, TS, and s-TfR in HD patients and to predict their agreement (assessed by kappa) in the diagnosis of iron deficiency, and, secondly, to assess the influence of inflammation on the relation between the parameters of iron state. Iron deficiency by either marker was respectively defined as ferritin <100 microg/l, TS <20%, or s-TfR >2.4 microg/ml. In the overall group of patients, TS and s-TfR were significantly related (r = -0.38), whereas s-TfR and serum ferritin were not. Both serum ferritin and TS were related to CRP (r = 0.50 and -0.34; p < 0.05), whereas s-TfR was not. The kappa value for agreement between serum ferritin and TS in the diagnosis of iron deficiency was 0.24 (p = 0.07), 0.12 (p = NS) for the agreement between TS and s-TfR and 0 for that between serum ferritin and s-TfR. In patients with CRP levels <or=2 mg/l (n = 16), the relation between parameters of iron state did not improve. Concluding, a large disagreement is observed between ferritin, TS and sTfR as markers of iron deficiency in HD patients, which appears to be only partly explained by the effect of inflammation.

Adult↗

Thermal effects of different dialysis techniques and blood pump speeds: an in vitro study.

Thermal effects have a pivotal impact on hemodynamic stability during dialysis procedures. In contrast to conventional dialysis techniques, there are no data in the literature regarding the thermal energy balance during on-line techniques. Secondly, little data exist on the effect of extracorporeal blood pump speed (EBPS) on thermal energy balance. In this study we assessed, first, relative differences in energy transfer rate (ETR) over the extracorporeal circuit during on-line hemo(dia)filtration (H(D)F) procedures and hemodialysis (HD) at different dialysate temperatures during an in vitro procedure using a blood temperature monitor (BTM). Secondly, we assessed the thermal effects of different blood pump speed (BPS) rates during the various treatment modalities. ETR was different among all treatment modalities (p < 0.05) studied, except for HD at 36.5 degrees C vs. pre-dilution hemofiltration (HF) and post-dilution HDF vs. HD at 37.5 degrees C. ETR had the most negative result, indicating the largest energy loss, during HD at 35.5 degrees C (-58.5.2 +/- 2.6 W), whereas it was almost comparable between pre-dilution HF (-30.7 +/- 4.1 W) and HD at 36.5 degrees C (-35.1.2 +/- 2.4 W). Post-dilution HDF (-17.7 +/- 1.2 W) resulted in an ETR comparable to that of HD at 37.5 degrees C (-15.0 +/- 3.9 W). ETR during post-dilution HF was -43.8 +/- 1.3 W. The thermal effect of the BPS was more pronounced during the procedures with the more negative ETR. In conclusion, on-line techniques and BPS have widely varying effects on ETR during dialysis, which should be considered when the hemodynamic effects among different treatment modalities are compared.

Analysis of Variance↗