PubMed Health⌕ Search

Biomedical subjects

Charles Bloch

Publications and source records attributed to Charles Bloch.

6 recordsLinked to original sources

Detection of IMRT delivery errors using a quantitative 2D dosimetric verification system.

We investigated the feasibility of detecting intensity modulated radiotherapy delivery errors automatically using a scalar evaluation of two-dimensional (2D) transverse dose measurement of the complete treatment delivery. Techniques using the gamma index and the normalized agreement test (NAT) index were used to parametrize the agreement between measured and computed dose distributions to seven different scalar metrics. Simulated verifications with delivery errors calculated using a commercially available treatment planning system for 9 prostate and 7 paranasal sinus cases were compared to 433 clinical verifications. The NAT index with 5% and 3 mm criteria that included cold areas outside the planning target volume detected the largest percent of delivery errors. Assuming a false positive rate of 5%, it was able to detect 88% of beam energy changes, 94% of a different patient's plan being delivered, 25% of plans with one beam's collimator rotated by 90 degrees, 81% of rotating one beam's gantry angle by 10 degrees, and 100% of omitting the delivery of one beam. However, no instances of changing one beam's monitor unit setting by 10% or shifting the isocenter by 5 mm were detected. Although the phantom shift could not be detected by the small change it made in the dose distribution, our autopositioning algorithm clearly identified the spatial anomaly. Using tighter 3 %/2 mm criteria or combining dose and distance disagreements in an either/or fashion resulted in poorer delivery error detection. The mean value of the 2D gamma index distribution was less sensitive to delivery errors than the other scalar metrics studied. Although we found that scalar metrics do not have sufficient delivery error detection rates to be used as the sole clinical analysis technique, manually examining 2D dose comparison images would result in a near 100% detection rate while performing an ion chamber measurement alone would only detect 54% of these errors.

Algorithms↗

Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.

Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured the dosimetric accuracy and reproducibility of calibrated Kodak EDR2 film for single-beam verifications in a solid water phantom and for full-plan verifications in a Rexolite phantom. Repeated measurements of the film sensitometric curve in a single experiment yielded overall uncertainties in dose of 2.1% local and 0.8% relative to 300 cGy. 547 film calibrations over an 18-month period, exposed to a range of doses from 0 to a maximum of 240 MU or 360 MU and using 6 MV or 18 MV energies, had optical density (OD) standard deviations that were 7%-15% of their average values. This indicates that daily film calibrations are essential when EDR2 film is used to obtain absolute dose results. An elemental analysis of EDR2 film revealed that it contains 60% as much silver and 20% as much bromine as Kodak XV2 film. EDR2 film also has an unusual 1.69:1 silver:halide molar ratio, compared with the XV2 film's 1.02:1 ratio, which may affect its chemical reactions. To test EDR2's intermittency effect, the OD generated by a single 300 MU exposure was compared to the ODs generated by exposing the film 1 MU, 2 MU, and 4 MU at a time to a total of 300 MU. An ion chamber recorded the relative dose of all intermittency measurements to account for machine output variations. Using small MU bursts to expose the film resulted in delivery times of 4 to 14 minutes and lowered the film's OD by approximately 2% for both 6 and 18 MV beams. This effect may result in EDR2 film underestimating absolute doses for patient verifications that require long delivery times. After using a calibration to convert EDR2 film's OD to dose values, film measurements agreed within 2% relative difference and 2 mm criteria to ion chamber measurements for both sliding window and step-and-shoot fluence map verifications. Calibrated film results agreed with ion chamber measurements to within 5 % /2 mm criteria for transverse-plane full-plan verifications, but were consistently low. When properly calibrated, EDR2 film can be an adequate two-dimensional dosimeter for IMRT verifications, although it may underestimate doses in regions with long exposure times.

Dose-Response Relationship, Radiation↗

Retrospective analysis of 2D patient-specific IMRT verifications.

We performed 858 two-dimensional (2D) patient-specific intensity modulated radiotherapy verifications over a period of 18 months. Multifield, composite treatment plans were measured in phantom using calibrated Kodak EDR2 film and compared with the calculated dose extracted from two treatment planning systems. This research summarizes our findings using the normalized agreement test (NAT) index and the percent of pixels failing the gamma index as metrics to represent the agreement between measured and computed dose distributions. An in-house dose comparison software package was used to register and compare all verifications. We found it was important to use an automatic positioning algorithm to achieve maximum registration accuracy, and that our automatic algorithm agreed well with anticipated results from known phantom geometries. We also measured absolute dose for each case using an ion chamber. Because the computed distributions agreed with ion chamber measurements better than the EDR2 film doses, we normalized EDR2 data to the computed distributions. The distributions of both the NAT indices and the percentage of pixels failing the gamma index were found to be exponential distributions. We continue to use both the NAT index and percent of pixels failing gamma with 5%/3 mm criteria to evaluate future verifications, as these two metrics were found to be complementary. Our data showed that using 2%/2 mm or 3%/3 mm criteria produces results similar to those using 5%/3 mm criteria. Normalized comparisons that have a NAT index greater than 45 and/or more than 20% of the pixels failing gamma for 5%/3 mm criteria represent outliers from our clinical data set and require further analysis. Because our QA verification results were exponentially distributed, rather than a tight grouping of similar results, we continue to perform patient-specific QA in order to identify and correct outliers in our verifications. The data from this work could be useful as a reference for other clinics to indicate anticipated trends in 2D verifications under various conditions.

Algorithms↗

Dosimetric benefits of respiratory gating: a preliminary study.

In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (CT) image data sets were acquired for 10 patients who had been diagnosed with primary bronchogenic carcinoma. Data sets were acquired during free breathing and during breath-holds at 0% tidal volume and 100% tidal volume, and, when possible, at deep inspiration, corresponding to approximately 60% vital capacity. Two treatment plans were developed on the basis of each of the gated data sets: one in which the treatment portals were those of the free-breathing plan, and the other in which the treatment portals were based on the gated planning target volumes. Dose-mass histograms of the lungs calculated at 0% tidal volume were compared to those calculated at deep inspiration and at 100% tidal volume. Data extracted from the dose-mass histograms were used to determine the most dosimetrically beneficial point to gate, the reduction in the amount of irradiated lung tissue that resulted from gating, and any disease characteristics that might predict a greater need for gating. The data showed a reduction in the mass of normal tissue irradiated when treatment portals based on the gated planning target volume were used. More normal lung tissue was spared at deep inspiration than at the other two gating points for all patients, but normal lung tissue was spared at every point in the respiratory cycle. No significant differences in the amount of irradiated tissue by disease characteristic were identified. Respiratory gating of thoracic radiation treatments can often improve the quality of the treatment plan, but it may not be possible to determine which patients may benefit from gating prior to performing the actual treatment planning.

Artifacts↗

Linearity and uniformity response as an indicator of performance for Agfa ADC-MD10 computed radiography plates.

Computed radiography (CR) plates are currently used in radiation therapy clinics to acquire digital radiographic images for the purpose of verifying the treatment field size, shape, and location. Each CR plate may be used numerous times, and the use of these digital images allows for easy storage and retrieval of patient data. Over prolonged repeat exposures of the CR plates, however, the image quality begins to degrade, making it increasingly more difficult for the therapists and physicians to determine where one anatomical structure begins, and the other ends. The purpose of this project was to analyze and compare the linearity and uniformity responses of new CR plates, versus CR plates that have been used clinically for a period of 2 years, and determine whether linearity or uniformity response may be used as an indicator of image quality degradation. To determine this, 44 old Agfa MD10 CR plates and 56 new Agfa MD10 CR plates were tested. When comparing the results of the uniformity test, we found both the old and the new plates varied from approximately 0.5% to 3.2%. When comparing the results of the linearity test, we found that the correlation coefficient, R(2), for both the old and the new plates varied from approximately 0.996 to 0.998, with the mean values being 0.9972 and 0.9979, respectively. We concluded that linearity and uniformity response cannot be used as an effective method for the evaluation of CR plate performance. Additional research is currently underway to evaluate various other methods of assessing CR plate performance.

Algorithms↗

Proton therapy for exudative age-related macular degeneration: a randomized, sham-controlled clinical trial.

PURPOSE: To examine the effect of proton beam irradiation on subfoveal choroidal neovascular membranes (CNVM) associated with age-related macular degeneration (AMD).Randomized, prospective, sham-controlled, double-masked treatment trial. METHODS: Thirty-seven subjects with subfoveal CNVM due to AMD were randomly assigned to 16-Gy proton irradiation delivered in two fractions 24 hours apart or to sham control treatment. Recruitment was halted at 37 subjects for ethical reasons regarding randomization to sham treatment when Food and Drug Administration approval of Visudyne was anticipated. RESULTS: Proton irradiation was associated with a trend toward stabilization of visual acuity, but this association did not reach statistical significance. No correlations were found within the fluorescein angiography data, including greatest linear dimension of CNVM total size, area of active leakage, area of associated subretinal hemorrhage, and intensity. CONCLUSIONS: With the acceptance of photodynamic therapy, future studies will require more complex design and larger sample size to determine whether radiation can play either a primary or adjunctive role in treating these lesions.

Aged↗