The continued evolution of the credit system.

In its ongoing support of continuous physician professional development, the American Medical Association (AMA) for use in the AMA Physician's Recognition Award has adopted 2 new learning platforms: Performance Improvement (PI) and Internet Point of Care (PoC). This article highlights the process that led to their adoption and places these new forms of continuing and physician professional development in the framework of existing continuing medical education (CME). The article calls for new research that revisits existing data on physician learning and prepares to incorporate provider experience with "practice situated" forms of CME. The Conjoint Committee on CME may serve as an important contributor to this process by enabling valuable dialogue among stakeholder organizations.

American Medical Association↗

Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.

Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (Lamb) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/ secondary displays are maximum luminance of greater than 170/100 cd/m2, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u',v' color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.

Computer Graphics↗

Measurement of CT radiation profile width using CR imaging plates.

This paper describes the procedure for using a Fuji computed radiography (CR) imaging plate (IP) for the measurement of computed tomography (CT) radiation profiles. Two sources of saturation in the data from the IP, signal and quantization, were characterized to establish appropriate exposure and processing conditions for accurate measurements. The IP generated similar profiles compared to those obtained from digitized ready-pack films, except at the profile edges, where the exposure level is low. However, when IP pixel values are converted to exposure, CR and digitized film profiles are in agreement. The full width at half maximum (FWHM) of the CT radiation profile was determined from the relationship between pixel value and exposure and compared to FWHM of the digitized optical density profile from film. To estimate the effect of scattering by the cassette material, radiation profiles were acquired from IPs enclosed in a cassette or in a paper envelope. The presence of the cassette made no difference in the value determined for FWHM. With proper exposure and processing conditions, the FWHM of 5, 10, and 15 mm collimated beams were measured using IPs to be 7.1, 11.9, and 17.0 mm and using film to be 7.2, 12.2, and 16.8 mm, respectively. Our results suggest that, under appropriate conditions, the estimation of the width of the CT radiation profile using Fuji CR is comparable to the measurement from film density described in American Association of Physicists in Medicine (AAPM) Report No. 39. Although our experiment was conducted using Fuji CR, we anticipate that CR plates from other vendors could be successfully used to measure CT beam profiles because of similar empirical relationships between pixel value and exposure.

Radiation Dosage↗

A new metric for continuing medical education credit.

The two major continuing medical education (CME) credit systems for allopathic physicians in the United States are administered by the American Medical Association (AMA) and the American Academy of Family Physicians (AAFP). This article explores the history of AMA and AAFP CME credit and its value to physicians and the patients they serve. Historically, CME credit has been awarded as hours for participation, but this approach is inadequate as a measure of CME and its impact on improving physician practice. New credit systems are needed to measure a CME activity by its value in bettering the physician's knowledge base, competence, and performance in practice.

American Medical Association↗

Implementing the DICOM Grayscale Standard Display Function for mixed hard- and soft-copy operations.

The aim of this work was to implement the DICOM Grayscale Standard Display Function (GSDF) at all stages of image presentation for computed radiography (CR) and direct digital radiography (DR) modalities. Cathode-ray tubes (CRT) were calibrated according to vendor procedures. Printer look-up-tables (LUT) were measured. Custom LUTs were created and loaded. Fuji CR gradation processing parameters were adjusted to accommodate a GSDF printer LUT. Conformance to the GSDF for hard-copy and soft-copy displays was measured with DICOM Part 14 procedures. One system was intended to completely incorporate the GSDF, although the hard-copy result was correct. The CR systems required creation of custom GSDF printer LUTs, adjustment of gradation processing parameters, and/or calibration of CRT luminance response at the quality control station. The picture archiving and communication system workstations from one vendor required third-party software for calibration. Current implementations of DICOM GSDF by vendors may be inconsistent or nonexistent. Significant effort by in-house staff must be expended to properly incorporate the GSDF.

Data Display↗