PubMed Health⌕ Search

Biomedical subjects

Charles H Tegeler

Publications and source records attributed to Charles H Tegeler.

13 recordsLinked to original sources

Screening for high-grade carotid stenosis using a portable ultrasonography instrument.

BACKGROUND AND PURPOSE: We investigated the diagnostic performance of a brief Power Doppler Imaging (PDI) screening examination for carotid artery stenoses using a newly developed portable instrument. METHODS: A highly experienced sonographer screened in total 152 carotid arteries by either continuous wave (cw) Doppler (n= 50) or a lightweight (2.4 kg) portable duplex device (n= 102) in a prospective study of 76 high-risk patients. The screening protocols included either spectrum analysis and frequency shift measurement in both internal carotid arteries with cw-Doppler or determination of area and diameter ratios in transverse and longitudinal views of both carotid arteries in B-mode and with PDI, but without velocity measurement. Both protocols were evaluated against a complete routine duplex ultrasonography examination. RESULTS: According to the complete examination, stenoses were <50% in 73 of 102 (71.6%), 50-75% in 19 of 102 (18.6%), 75-95% in 7 of 102 (6.9%), and occluded in 3 of 102 (2.9%) arteries (PDI cohort), and <50% in 39 of 50 (78%), 50-75% in 8 of 50 (16%), 75-95% in 2 of 50 (4%), and occluded in 1 of 50 (2%) artery (cw-Doppler cohort). Mean screening time was 8.8 +/- 2.5 minute (PDI) and 9.4 +/- 2.6 minute (cw-Doppler). For stenoses >75%, A(z) values (area under the receiver operating characteristics curve) were 0.897 for area ratios, 0.843 for diameter ratios (PDI protocol) and 1.0 for the cw-Doppler protocol. CONCLUSIONS: The diagnostic performance of the cw-Doppler protocol was superior to the PDI protocol. Nevertheless, both protocols appear suitable as inexpensive screening strategies to identify subjects with >75% stenosis measured by carotid Doppler ultrasound. However, these preliminary data need further verification.

Aged↗

Dynamic vascular analysis shows a hyperemic flow pattern in sickle cell disease.

BACKGROUND: By the age of 20 years, 10% of sickle cell disease (SCD) patients have experienced a stroke. It is unclear if SCD stroke is due primarily to hemodynamic effects of intracranial stenosis, or metabolic failure from anemia. Transcranial Doppler ultrasound (TCD) identifies a SCD subgroup with high stroke risk, but high mean flow velocity (MFV) can be due to stenosis or high flow rate, as with metabolic hyperemia of severe anemia. Dynamic Vascular Analysis (DVA; New Health Sciences, Inc., Bethesda, MD) is a new way to analyze TCD data, with potential to separate structural from metabolic causes of high MFV. METHODS: Eighty SCD patients, regardless of hemoglobin genotypes, aged 2 to 22 years, without clinical stroke or transient ischemic attack (TIA), who had TCD (1/1/02 to 1/1/04) as part of routine outpatient clinical follow-up, with both the TCD report and study videotape available, were included. Waveforms were reviewed and marked by protocol, and DVA indices calculated including MFV, pulsatility index (PI), systolic acceleration (SA), dynamic flow index (DFI), dynamic pressure index (DPI), and dynamic compliance index (DCI). Mean and standard deviation were defined for the whole group, and for four subgroups, by age. RESULTS: MFV, DFI, and DPI were highest at 6- to 9-year-olds, declining thereafter. The 14- to 22-year-old group was also compared to a group of healthy young athletes (15- to 22 years old). SCD patients had higher MFV, lnSA, DFI, DPI, and lower PI and DCI in most segments, suggesting global hyperemia. CONCLUSION: This is the first report of cross-sectional results of DVA in a cohort of SCD outpatients without prior clinical stroke (TIA). These results suggest hyperemia without significant focal intracranial stenosis. There were also differences between asymptomatic SCD and young athletes, and the MFV, DFI, and DPI were highest at the age of 6 to 9 years, decreasing as age increased.

Adolescent↗

Differentiating vascular pathophysiological states by objective analysis of flow dynamics.

BACKGROUND AND PURPOSE: There is an unmet need to classify cerebrovascular conditions physiologically and to assess cerebrovascular system performance. The authors hypothesized that by simultaneously considering the dynamic parameters of flow velocity, acceleration, and pulsatility index (PI) (impedance) in individual Doppler spectrum waveforms, they could develop an objective method to elucidate the pathophysiology of vascular conditions and classify cerebrovascular disorders. This method, dynamic vascular analysis (DVA), is described. METHODS: First, a theoretical model was developed to determine how any vascular segment and the ensemble of intracranial vascular segments could be defined according to its dynamic physiological characteristics. Next, the DVA method was applied to 847 anonymous serial complete clinical transcranial Doppler (TCD) studies of patients without regard for their diagnosis to ascertain actual reference ranges and the normality of the distribution curves for each dimension of the 3-parameter nomogram. The authors applied DVA to 2 clinical cases to see if they could track the changes in vascular performance of 2 known progressive diseases. RESULTS: The theoretical analysis identified 295,245 possible vascular states for the ensemble of vascular segments in the cerebral circulation. When applied to clinical TCD data, DVA revealed continuous, normally distributed data for the velocity, PI, and logarithm of the acceleration. CONCLUSIONS: DVA is proposed as a method for monitoring the physiological state of each cerebral artery segment individually and in ensemble. DVA evaluates the relationship among acceleration (force or pressure), velocity, and PI and provides an objective means to evaluate intracranial vascular segments using the paradigm of the well-described pressure-perfusion autoregulation relationship. DVA may be used to study cerebrovascular pathophysiology and to classify, evaluate, and monitor cerebrovascular disorders or systemic disorders with cerebrovascular effects.

Adult↗

Measurement of carotid stenosis: comparisons between duplex and different angiographic grading methods.

BACKGROUND AND PURPOSE: Endarterectomy has been proved to be an effective stroke prevention procedure. However, there are still inconsistencies between the results of different preoperative evaluation methods, which may sometimes complicate treatment plans. This study measured the discrepancies between different angiographic grading methods and attempted to further assess the accuracy of the carotid duplex examination according to these different angiographic grading methods. METHODS: One hundred seventy-one preendarterectomy carotid duplex examinations and angiograms were reviewed. All angiograms were measured blindly by one of the authors using the North American Symptomatic Carotid Endarterectomy Trial (N), the European Carotid Surgery Trial (E), and the common carotid (C) methods. The measurement results were further converted into the area of stenosis indices (N2, E2, and C2, respectively). By using regression testing, all results could be compared. The duplex examination data were then compared with the results of different angiographic measurement methods to evaluate their accuracy. RESULTS: The measurement results of all angiographic grading methods were well correlated. Using different angiographic grading systems as the gold standard, duplex examination for screening endarterectomy candidates produced the following results: According to the N method, accuracy was 74%; according to the E method, accuracy was 90%; and according to the C method, the accuracy rate was 92%. According to N2, accuracy was 88%; according to E2, accuracy was 94%; and according to C2, the accuracy rate was 93%. CONCLUSIONS: The measurement results of all 3 commonly used angiographic grading methods were linearly correlated with one another. (It is important to note that none of those standards should be treated as the only gold standard.) In this study, the duplex criteria have a greater accuracy rate according to E or C rather than N. However, this study also demonstrated that the cut point of the Doppler criteria is the determinant factor for accuracy rather than which gold standard was compared. Through careful adjustment of the cutoff criteria, carotid duplex can be highly accurate, despite the use of different reference standards.

Aged↗

A multiple regression model of combined duplex criteria for detecting threshold carotid stenosis and predicting the exact degree of carotid stenosis.

BACKGROUND AND PURPOSE: Combined duplex criteria are commonly used in vascular laboratories for evaluating carotid stenosis. However, most of these combinations are empirical, and systemic validation is lacking. This study was completed using a multiple regression method to evaluate the accuracy of different combined duplex criteria for detecting threshold carotid stenosis and predicting the exact degree of carotid stenosis on angiography. METHODS: Two hundred sixty-six sets of unilateral carotid duplex and angiographic data were randomly divided into 2 sets: a derivation set and a validation set. The derivation set was used to develop a multiple logistic regression model for detecting 70% threshold carotid stenosis. Age, sex, systolic blood pressure, diastolic blood pressure, Doppler peak systolic velocity (PSV), Doppler and diastolic velocity (EDV), the systolic carotid ratio (SCR), and ophthalmic artery flow direction were tested as independent variables. A multiple linear regression model was also developed for predicting the exact degree of carotid stenosis on angiogram. The validation set was then used to evaluate the accuracy of these models. RESULTS: According to the logistic regression strategy, the best multiple logistic regression model was as follows: probability of threshold carotid stenosis = exp(2.6 PSV - 6.2)/[1 + exp(2.6 PSV - 6.2)]. The best linear regression model was as follows: degree of carotid stenosis = 20.2 PSV - 7.4 EDV + 0.4 SCR + 8.5. Both models proved to be valid following an evaluation of the validation set. CONCLUSIONS: This study illustrates that Doppler parameters may be of use in predicting the exact degree of carotid stenosis and the probability of threshold carotid stenosis. This is important if duplex criteria are going to replace angiography as the only tool for selecting endarterectomy candidates.

Aged↗

Detection of air microbubbles in the internal jugular vein after intravenous injection of contrast agent for the diagnosis of patent foramen ovale.

The use of agitated air and saline, injected intravenously, combined with monitoring of the middle cerebral artery using transcranial Doppler sonography, is an effective method for detecting paradoxic cerebral embolism caused by right-to-left intracardiac shunting. This technique is particularly useful in patients with a patent foramen ovale. In patients without temporal acoustic windows, the method can be modified by using sonographic monitoring of the common carotid artery. Observation of saline-contrast microbubbles in the internal jugular vein during this procedure suggests incompetence of the ipsilateral internal jugular valve. This noninvasive method may thus be useful for studying the competence of the internal jugular valve.

Aged↗

Ophthalmic artery flow direction on color flow duplex imaging is highly specific for severe carotid stenosis.

BACKGROUND/PURPOSE: Collateral flow patterns are important risk factors for brain ischemia in the presence of internal carotid artery (ICA) stenosis or occlusion. Ophthalmic artery (OA) flow reversal, routinely studied by transcranial Doppler sonography, is an important marker for high-grade ICA stenosis or occlusion. The authors sought to define the value of assessing OA flow direction with color flow duplex ultrasonography (CDUS) in the setting of significant ICA disease. METHODS: Of all patients having routine carotid ultrasound in the neurosonology laboratory between July 1995 and November 2000, 152 had both carotid and orbital (OA flow direction by reduced power orbital CDUS) examinations as well as angiographic confirmation of stenosis to which North American Symptomatic Carotid Endarterectomy Trial criteria could be applied. Degree of angiographic stenosis in these 152 patients (304 arteries) was correlated with OA flow direction. RESULTS: Of 304 arteries, 101 had greater than 80% stenosis by angiogram. In 56 of these 101 arteries with high-grade stenosis or occlusion, the ipsilateral OA was reversed; however, OA flow direction was never reversed ipsilateral to arteries with less than 80% stenosis (sensitivity 55%, specificity 100%, negative predictive value 82%, and positive predictive value 100% for OA flow reversal as a marker of high-grade carotid lesions). DISCUSSION/CONCLUSIONS: OA flow direction is easily studied with CDUS. Reversed OA flow direction is highly specific (100%) for severe ipsilateral ICA stenosis or occlusion, with excellent positive predictive value, moderate negative predictive value, and limited sensitivity. OA flow reversal is not only quite specific for severe ICA disease, which may be helpful if the carotid CDUS is difficult or inadequate, but may also provide additional hemodynamic insights (i.e., the inadequacy of other collateral channels such as the anterior communicating artery). OA evaluation can provide important hemodynamic information and should be included as part of carotid CDUS if there is any evidence of ICA stenosis or occlusion.

Blood Flow Velocity↗

Hemodynamic effects of innominate artery occlusive disease on anterior cerebral artery.

Stenoses of the innominate artery (IA) may affect flow conditions in the carotid arteries. However, alternating flow in ipsilateral anterior cerebral artery (ACA) due to IA stenosis is extremely rare. A 49-year-old woman who was evaluated for symptomatic cerebrovascular disease presented with right latent subclavian and right carotid system steal. Transcranial Doppler examination displayed systolic deceleration wave-forms in the right terminal internal carotid artery and alternating flow in the right ACA. Magnetic resonance angiography demonstrated tight stenosis of the right IA. For a thorough study of the hemodynamic effects of IA stenosis, a combination of duplex and transcranial Doppler examination is required.

Anterior Cerebral Artery↗

Doppler velocity criteria based on receiver operating characteristic analysis for the detection of threshold carotid stenoses.

BACKGROUND AND PURPOSE: Duplex scanning is an accepted method for noninvasive evaluation of carotid stenosis. However, the ultrasound criteria used for the detection of threshold stenoses vary widely between laboratories, and quality assurance measures to allow adjustment of criteria are often lacking. This study was completed using receiver operating characteristic (ROC) analysis to determine Doppler velocity criteria for threshold carotid stenoses, compared to an accepted standard, and to demonstrate methods to allow adjustment of criteria. METHODS: The study cohort included 134 patients who had carotid endarterectomy. Ultrasound and arteriographic data were collected for both the operated and nonoperated sides. Each carotid artery was treated as an independent case in the final analysis. Angiograms were used as the gold standard in ROC analysis to determine the Doppler velocity criteria for the detection of different threshold stenoses. RESULTS: The ROC analysis results showed that for the detection of 70% stenosis, the best Doppler systolic criterion was 200 cm/s (sensitivity 93.6%, specificity 71.7%, area under the curve [AUC] 87.6%), the best diastolic criterion was 65 cm/s (sensitivity 85.1%, specificity 74.6%, AUC 84.3%), and the best criterion of carotid ratio (CR) (internal carotid artery systolic velocity/common carotid artery systolic velocity) was 3.0 (sensitivity 78.7%, specificity 75.4%, AUC 81.3%). For 50% stenosis, the best systolic criterion was 140 cm/s (sensitivity 90.3%, specificity 95.2%, AUC 97.0%), the best diastolic criterion was 60 cm/s (sensitivity 98.6%, specificity 77.8%, AUC 92.1%), and the best criterion of CR was 2.5 (sensitivity 93.1%, specificity 72.0%, AUC 89.0%). CONCLUSIONS: This study showed that duplex scanning is able to detect threshold carotid stenoses. For the best performance, each laboratory should have its own criteria; however, the criteria provided here could be a helpful reference to those laboratories that have not yet established their own criteria. Most important, this study provides an example of how to evaluate the performance criteria, how to modify them, how such changes can affect performance, and how performance can be modified depending on the goals of the laboratory.

Aged↗

Subclavian steal syndrome: can the blood pressure difference between arms predict the severity of steal?

BACKGROUND AND PURPOSE: A side-to-side difference in systolic brachial arterial blood pressure is a common finding in subclavian artery stenosis and is frequently used as a screening tool for subclavian steal syndrome (SSS). It was the goal of this retrospective study to investigate the relationship between different vertebral artery waveform types and the side-to-side difference in systolic blood pressure in patients with sonographically proven SSS. METHODS: The records of 1860 patients from the Neuroultrasound Laboratory between January 2000 and December 2000 were screened for the diagnosis of SSS in the final ultrasound report. In all patients, bilateral brachial arterial blood pressure was measured in a sitting position prior to the ultrasound examination. Vertebral artery waveforms were classified as (1) systolic deceleration, (2) alternating flow, and (3) complete reversal at rest. Blood pressure difference as calculated by normal-side blood pressure minus lesion-side blood pressure was compared with the 3 Doppler waveform types. RESULTS: SSS was found in 51 of 1860 (2.7%) ultrasonography studies of 49 patients (17 men, 32 women; mean age 65.3 +/- 10.5 years). Two patients (4%) had bilateral SSS. In 3 patients (6%), SSS was related to an innominate artery stenosis. Waveform analysis showed a completely reversed flow in 16 (31%), an alternating flow in 24 (47%), and a systolic deceleration in 11 (22%) cases. Systolic blood pressure difference was significantly higher in the complete reversal and alternating groups than in the systolic deceleration group (P < .001). CONCLUSION: Brachial systolic blood pressure difference is related to the severity of SSS and can be used as a screening tool for SSS. However, it performed better in severe steal than milder steal phenomena.

Aged↗

Extracranial internal carotid artery occlusion: the role of common carotid artery volume flow.

BACKGROUND AND PURPOSE: Quantitative measurement of blood flow volume in the common carotid artery (CCA) is now possible using the color velocity imaging quantification (CVI-Q) ultrasound technique. The aim of this study was to evaluate the cerebral hemodynamic effects of unilateral internal carotid artery (ICA) occlusion on CCA blood flow volumes (FVs) using CVI-Q. METHODS: Records of ultrasound studies in our neurosonology laboratory were retrospectively reviewed to identify patients with unilateral ICA occlusions who at a minimum received both a routine color duplex carotid ultrasound examination and quantitative measurement of FV in the CCA, bilaterally, using the CVI-Q method. A total of 71 patients met criteria and were included in the cohort. A side to side comparison was performed for FV, peak systolic velocities (PSV), end-diastolic velocities (EDV), and resistance indices (RIs) in the CCA. Results correlated with any other available data such as flow direction in the ophthalmic artery and the presence of intracranial collateralization. RESULTS: The FV, PSV, and EDV were significantly reduced, and the RI was significantly increased in the CCA on the side of the occlusion. A subgroup analysis in patients who also had an examination of the ophthalmic (n = 61) and the intracranial arteries of the Circle of Willis (n = 50), showed significantly higher FV in the CCA on the side of the occlusion if there was also reversed flow in the ophthalmic artery on the side of the occlusion (344 +/- 144 ml/min versus 169 +/- 53 ml/min). CONCLUSION: Quantitative FV measurement using CVI-Q ultrasound can identify clear alterations in volume flow, collateral pathways, and cerebral hemodynamics in patients with unilateral ICA occlusion. It is a complementary tool, providing additional objective information about the cerebral hemodynamic effects of ICA occlusion that goes beyond what is available using routine flow velocity data.

Aged↗

Transcranial Doppler ultrasound: a new method of monitoring hemispheric anesthetization during the intracarotid amobarbital procedure.

BACKGROUND: Electroencephalography (EEG) is traditionally used to assess the duration of hemispheric anesthetization and to monitor return of function in the anesthetized hemisphere during the intracarotid amobarbital procedure (IAP), but EEG changes are not consistently seen. The authors evaluated the role of continuous transcranial Doppler (TCD) monitoring as an alternative to EEG. METHODS: The authors performed both continuous TCD monitoring and EEG during the IAP in 10 patients with medically intractable partial epilepsy. Mean velocities were monitored continuously in both middle cerebral arteries (MCAs), and changes in MCA velocities on continuous TCD monitoring were time locked with the EEG changes. RESULTS: The average mean MCA velocities were within normal limits bilaterally (50-85 cm/s) in all patients at baseline. Mean MCA velocites increased in all patients to 95-115 cm/s at the start of the test when the patients were asked to raise their hands and start counting. After injection of sodium amobarbital, mean MCA velocities in all patients dropped dramatically on the ipsilateral side to values of 12-39 cm/s and returned to the baseline average value when the hemiparesis recovered. In 8 patients, the duration of delta activity on EEG coincided with the time interval during which the mean MCA velocities were low on TCD monitoring. In 2 patients, despite the presence of hemiparesis clinically and a drop in mean MCA velocities on the ipsilateral side on continuous TCD monitoring, EEG remained normal on the ipsilateral side. CONCLUSIONS: Continuous TCD monitoring may be a more sensitive method than EEG in determining the duration of hemispheric anesthetization during IAP. Because the items for assessment of memory are presented during the period of hemispheric anesthetization, TCD may be useful in more precisely defining the time window for memory testing.

Amobarbital↗