PubMed Health⌕ Search

Biomedical subjects

Charles L Asbury

Publications and source records attributed to Charles L Asbury.

7 recordsLinked to original sources

The Dam1 kinetochore complex harnesses microtubule dynamics to produce force and movement.

Kinetochores remain attached to microtubule (MT) tips during mitosis even as the tips assemble and disassemble under their grip, allowing filament dynamics to produce force and move chromosomes. The specific proteins that mediate tip attachment are uncertain, and the mechanism of MT-dependent force production is unknown. Recent work suggests that the Dam1 complex, an essential component of kinetochores in yeast, may contribute directly to kinetochore-MT attachment and force production, perhaps by forming a sliding ring encircling the MT. To test these hypotheses, we developed an in vitro motility assay where beads coated with pure recombinant Dam1 complex were bound to the tips of individual dynamic MTs. The Dam1-coated beads remained tip-bound and underwent assembly- and disassembly-driven movement over approximately 3 microm, comparable to chromosome displacements in vivo. Dam1-based attachments to assembling tips were robust, supporting 0.5-3 pN of tension applied with a feedback-controlled optical trap as the MTs lengthened approximately 1 microm. The attachments also harnessed energy from MT disassembly to generate movement against tension. Reversing the direction of force (i.e., switching to compressive force) caused the attachments to disengage the tip and slide over the filament, but sliding was blocked by areas where the MT was anchored to a coverslip, consistent with a coupling structure encircling the filament. Our findings demonstrate how the Dam1 complex may contribute directly to MT-driven chromosome movement.

Chromosome Segregation↗

Kinesin: world's tiniest biped.

Kinesin, an essential motor protein that moves intracellular cargo along microtubules, walks like a person. When we walk, our feet exchange roles with each step, one moving and one remaining stationary. The moving foot travels twice as far as our torso during a single step, and our body alternates between two configurations (left vs. right leg leading). Recent work shows that kinesin shares all three of these hallmarks of bipedal walking. The challenge now is to determine how the gait of this lilliputian biped is coordinated.

Adenosine Diphosphate↗

The polarization of fluorescence of DNA stains depends on the incorporation density of the dye molecules.

BACKGROUND: The fluorescence induced by polarized light sources, such as the lasers that are used in flow cytometry, is often polarized and anisotropic. In addition, most optical detector systems are sensitive to the direction of polarization. These two factors influence the accuracy of fluorescence intensity measurements. The intensity of two light sources can be compared only if all details of the direction and degree of polarization are known. In a previous study, we observed that fluorescence polarization might be modified by dye-dye interactions. This report further investigates the role of dye density in fluorescence polarization anisotropy. METHODS: We measured the polarization distribution of samples stained with commonly used DNA dyes. To determine the role of fluorophore proximity, we compared the monomeric and a dimeric form of the DNA dyes ethidium bromide (EB), thiazole orange (TO), and oxazole yellow (YO). RESULTS: In all dyes sampled, fluorescence polarization is less at high dye concentrations than at low concentrations. The monomeric dyes exhibit a higher degree of polarization than the dimeric dyes of the same species. CONCLUSIONS: The polarization of fluorescence from DNA dyes is related to the density of incorporation into the DNA helix. Energy transfer between molecules that are in close proximity loosens the linkage between the excitation and emission dipoles, thereby reducing the degree of polarization of the emission.

Animals↗

Kinesin moves by an asymmetric hand-over-hand mechanism.

Kinesin is a double-headed motor protein that moves along microtubules in 8-nanometer steps. Two broad classes of model have been invoked to explain kinesin movement: hand-over-hand and inchworm. In hand-over-hand models, the heads exchange leading and trailing roles with every step, whereas no such exchange is postulated for inchworm models, where one head always leads. By measuring the stepwise motion of individual enzymes, we find that some kinesin molecules exhibit a marked alternation in the dwell times between sequential steps, causing these motors to "limp" along the microtubule. Limping implies that kinesin molecules strictly alternate between two different conformations as they step, indicative of an asymmetric, hand-over-hand mechanism.

Adenosine Triphosphate↗

Probing the kinesin reaction cycle with a 2D optical force clamp.

With every step it takes, the kinesin motor undergoes a mechanochemical reaction cycle that includes the hydrolysis of one ATP molecule, ADPP(i) release, plus an unknown number of additional transitions. Kinesin velocity depends on both the magnitude and the direction of the applied load. Using specialized apparatus, we subjected single kinesin molecules to forces in differing directions. Sideways and forward loads up to 8 pN exert only a weak effect, whereas comparable forces applied in the backward direction lead to stall. This strong directional bias suggests that the primary working stroke is closely aligned with the microtubule axis. Sideways loads slow the motor asymmetrically, but only at higher ATP levels, revealing the presence of additional, load-dependent transitions late in the cycle. Fluctuation analysis shows that the cycle contains at least four transitions, and confirms that hydrolysis remains tightly coupled to stepping. Together, our findings pose challenges for models of kinesin motion.

Adenosine Triphosphate↗

Trapping of DNA by dielectrophoresis.

Under suitable conditions, a DNA molecule in solution will develop a strong electric dipole moment. This induced dipole allows the molecule to be manipulated with field gradients, in a phenomenon known as dielectrophoresis (DEP). Pure dielectrophoretic motion of DNA requires alternate current (AC) electric fields to suppress the electrophoretic effect of the molecules net charge. In this paper, we present two methods for measuring the efficiency of DEP for trapping DNA molecules as well as a set of quantitative measurements of the effects of strand length, buffer composition, and frequency of the applied electric field. A simple configuration of electrodes in combination with a microfluidic flow chamber is shown to increase the concentration of DNA in solution by at least 60-fold. These results should prove useful in designing practical microfluidic devices employing this phenomenon either for separation or concentration of DNA.

Bacteriophage lambda↗

An automated two-dimensional optical force clamp for single molecule studies.

We constructed a next-generation optical trapping instrument to study the motility of single motor proteins, such as kinesin moving along a microtubule. The instrument can be operated as a two-dimensional force clamp, applying loads of fixed magnitude and direction to motor-coated microscopic beads moving in vitro. Flexibility and automation in experimental design are achieved by computer control of both the trap position, via acousto-optic deflectors, and the sample position, using a three-dimensional piezo stage. Each measurement is preceded by an initialization sequence, which includes adjustment of bead height relative to the coverslip using a variant of optical force microscopy (to +/-4 nm), a two-dimensional raster scan to calibrate position detector response, and adjustment of bead lateral position relative to the microtubule substrate (to +/-3 nm). During motor-driven movement, both the trap and stage are moved dynamically to apply constant force while keeping the trapped bead within the calibrated range of the detector. We present details of force clamp operation and preliminary data showing kinesin motor movement subject to diagonal and forward loads.

Automation↗