PubMed Health⌕ Search

Biomedical subjects

Charlotte Duverneuil

Publications and source records attributed to Charlotte Duverneuil.

5 recordsLinked to original sources

A novel LC-ESI-MS-MS method for sensitive quantification of colchicine in human plasma: application to two case reports.

A novel method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the identification and quantification of colchicine in plasma or whole blood. Colchicine was isolated from plasma using a liquid-liquid extraction with dichloromethane at pH 8.0 and embutramide as an internal standard, with satisfactory extraction recoveries. Solutes were separated on a 3-microm C18 Uptisphere (Interchim) column (150 x 2.0-mm i.d.) using acetonitrile/2 mM NH4COOH pH 3.8 buffer (50:50, v/v) as the mobile phase with a flow-rate of 200 microL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the ion m/z 400.1 for colchicine and m/z 294.1 for embutramide. The most intense daughter ion of colchicine (m/z 358.1) and embutramide (m/z 207.9) were used for quantification. Retention times were 2.40 and 4.25 min for colchicine and embutramide, respectively. Calibration curves were linear in the 0.50-50 ng/mL range. The limits of detection and quantification were 0.05 ng/mL and 0.50 ng/mL, respectively. The intra- and interassay precisions were < 14%, and the intra- and interassay accuracies were in the 97-105.8% range at either 2 or 20 ng/mL. A fatal case of colchicine self-poisoning with a lethal blood concentration of 60 ng/mL and nonfatal case with a plasma sample collected very late (at least 36 h after the ingestion) are presented. The described method enables the unambiguous identification and quantification of colchicine with a very good sensitivity, using only 1 mL of sample.

Adult↗

False homozygosities at various loci revealed by discrepancies between commercial kits: implications for genetic databases.

Routine control of 2055 consecutive genotypes revealed discrepancies between the profiles established with the SGM plus and/or Profiler plus kits on one hand, and the profiles established with the Powerplex16 kit on the other hand. Furthermore, five discrepancies for vWA, three for D8S1179, two for FGA and three for D18S51 loci were found. In 10 cases (loci vWA, FGA, D18S51, D8S1179), the SGM plus and/or Profiler plus profiles showed homozygosity and the Powerplex16 genotype revealed heterozygosities which were confirmed to be true, both by typing with individual primer pairs and DNA sequencing. In four cases (two discrepancies at locus FGA, one at D18S51 and an abnormal paternity pattern for D5S818), the Powerplex16 kit showed apparent homozygosity and the SGM plus and/or Profiler plus kits showed heterozygosity. Mutation analysis could be performed for some of these individuals and evidenced variants, presumably leading to an annealing failure of one primer; the identified mutations are reported. It is suggested that databases should include information about the kits used to determine the profiles while ensuring that the primer sequences are made available.

DNA↗

Simultaneous determination of thirteen beta-blockers and one metabolite by gradient high-performance liquid chromatography with photodiode-array UV detection.

A new rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed for the simultaneous identification and quantification in human plasma of the 13 most commonly prescribed beta-blockers and one active metabolite-atenolol, sotalol, diacetolol, carteolol, nadolol, pindolol, acebutolol, metoprolol, celiprolol, oxprenolol, labetalol, propranolol, tertatolol and betaxolol. It involves liquid-liquid extraction procedures followed by liquid chromatography coupled to photodiode-array UV detection with a fixed wavelength at 220 nm for quantification. Compounds were separated on a 5 microm Hypurity C(18) (ThermoHypersil) analytical column (250 mm x 4.6 mm, i.d.) using a gradient of acetonitrile-phosphate buffer pH 3.8 at a flow rate of 1.0 ml/min. The total analysis time was 26 min per sample. Extraction recoveries were between 74 and 113% for the polar compounds and between 20 and 56% for the most apolar compounds. Calibration lines were linear in the range from 25 to 1000 ng/ml for all compounds excepted carteolol and nadolol (50-1000 ng/ml), all of them with coefficients of determination (r2 values) >/=0.994. Limits of detection (LODs) ranged from 5 to 10 ng/ml. Intra-assay and inter-assay precision and accuracy were studied at two concentration levels (100 and 500 ng/ml). The intra-assay coefficients of variation (CVs) for all compounds were </= 8.3% and all inter-assays CVs were below 12.6%. The intra-assay and inter-assay accuracies for all compounds were found to be within 91.4 and 105.6% at 100 ng/ml and within 94.1 and 107.4% at 500 ng/ml. Thus, the performance of the method described allows its use in toxicological screening and in quantification of the most prescribed beta-blockers drugs.

Adrenergic beta-Antagonists↗

Liquid chromatography/photodiode array detection for determination of strychnine in blood: a fatal case report.

An original liquid chromatography method with photodiode-array detection (DAD) is presented for the determination of strychnine in blood. This sensitive method allows the use of only 0.1 ml of sample. The strychnine was isolated from blood using a liquid-liquid extraction procedure and chloroquine as an internal standard. The limits of detection (LOD) and quantification were 0.06 and 0.5 mg/l, respectively. The recovery was 94% and the coefficients of variation (CV) ranged from 5.9 to 10.8%. A fatal case of strychnine poisoning is presented, with a lethal blood concentration of 25 mg/l.

Adult↗

A high-performance liquid chromatography method with photodiode-array UV detection for therapeutic drug monitoring of the nontricyclic antidepressant drugs.

A new rapid and sensitive high-performance liquid chromatography method has been developed for the screening and determination in human plasma of the 11 most commonly prescribed nontricyclic antidepressants and two metabolites: fluoxetine, norfluoxetine, sertraline, paroxetine, citalopram, fluvoxamine, moclobemide, mirtazapine, milnacipram, toloxatone, venlafaxine, desmethyl venlafaxine, and viloxazine. It involves liquid-liquid extraction procedures followed by liquid chromatography coupled to photodiode-array UV detection with three fixed wavelengths (220, 240, and 290 nm). Compounds were separated on a 5-microm Hypurity C18 (ThermoHypersil) analytic column (250 x 4.6 mm i.d.) using a gradient of acetonitrile-phosphate buffer pH 3.8 at a flow rate of 1.0 mL/min. The total analysis time was only 18 min per sample. Extraction recoveries were in the 74-109% range for 11 compounds but were of only 59% for moclobemide and less than 10% for toloxatone. Calibration curves were linear in the 25 to 1000 ng/mL range for all compounds, all of them with coefficients of determination (r2 values) > or = 0.999. Limits of detection (LODs) ranged from 2.5 to 5 ng/mL except for toloxatone (10 ng/mL). Intraassay and interassay precision and accuracy were studied at two concentration levels (50 and 500 ng/mL). The intraassay coefficients of variation (CVs) for all compounds were < or = 7.6%, and all interassay CVs were below 11.5% except for milnacipram (14.8%). The intraassay and interassay accuracies for all compounds were found to be within 88.4% and 105.9% at 50 ng/mL and within 87.2% and 100.5% at 500 ng/mL. The performance of the method allows the therapeutic drug monitoring of the most prescribed nontricyclic antidepressant drugs as well as its use in toxicologic screening.

Antidepressive Agents↗