PubMed Health⌕ Search

Biomedical subjects

Che-Hsin Lin

Publications and source records attributed to Che-Hsin Lin.

14 recordsLinked to original sources

Rapid circular microfluidic mixer utilizing unbalanced driving force.

This paper proposes a novel rapid circular microfluidic mixer for micro-total-analysis-systems (mu-TAS) applications in which an unbalanced driving force is used to mix fluids in a circular chamber at low Reynolds numbers (Re). The microfluidic mixer has a three-layered structure and is fabricated on low-cost glass slides using a simple and reliable fabrication process. Using hydrodynamic pumps, fluids are driven from two inlet ports into a circular mixing chamber. Each inlet port separates into two separate channels, which are then attached to opposite sides of the 3-dimensional (3-D) circular mixing chamber. The unequal lengths of these inlet channels generate an unbalanced driving force, which enhances the mixing effect in the mixing chamber. Numerical simulations are performed to predict the fluid phenomena in the mixing chamber and to estimate the mixing performance under various Reynolds number conditions. The numerical results are verified by performing flow visualization experiments. A good agreement is found between the two sets of results. The numerical and experimental results reveal that the mixing performance can reach 91% within a mixing chamber of 1 mm diameter at a Reynolds number of Re=3. Additionally, the results confirm that the unbalanced driving force produces a flow rotation in the circular mixer at low Reynolds numbers, which significantly enhances the mixing performance. The novel micromixing method presented in this study provides a simple solution for mixing problems in Lab-on-a-chip systems.

Chemistry Techniques, Analytical↗

A rapid DNA digestion system.

This paper presents a novel microfluidic DNA digestion system incorporating a high performance micro-mixer. Through the appropriate control of fixed and periodic switching DC electric fields, electrokinetic forces are established to mix the DNA and restriction enzyme samples and to drive them through the reaction column of the device. The experimental and numerical results show that a mixing performance of 98% can be achieved within a mixing channel of length 1.6 mm when a 150 V/cm driving voltage and a 5 Hz switching frequency are applied. The relationship between the mixing performance, switching frequency, and main applied electric field is derived. It is found that the optimal switching frequency depends upon the magnitude of the main applied electric field. The successful digestion of lambda-DNA using Eco RI restriction enzyme is demonstrated. The DNA-enzyme reaction is completed within 15 min in the proposed microfluidic system, compared to 50 min in a conventional large-scale system. Hence, the current device provides a valuable tool for rapid lambda-DNA digestion, while its mixer system delivers a simple yet effective solution for mixing problems in the micro-total-analysis-systems field.

Bacteriophage lambda↗

Solving satisfiability problems using a novel microarray-based DNA computer.

An algorithm based on a modified sticker model accompanied with an advanced MEMS-based microarray technology is demonstrated to solve SAT problem, which has long served as a benchmark in DNA computing. Unlike conventional DNA computing algorithms needing an initial data pool to cover correct and incorrect answers and further executing a series of separation procedures to destroy the unwanted ones, we built solutions in parts to satisfy one clause in one step, and eventually solve the entire Boolean formula through steps. No time-consuming sample preparation procedures and delicate sample applying equipment were required for the computing process. Moreover, experimental results show the bound DNA sequences can sustain the chemical solutions during computing processes such that the proposed method shall be useful in dealing with large-scale problems.

Algorithms↗

Fabrication and characterization of semicircular detection electrodes for contactless conductivity detector - CE microchips.

This study uses simple and reliable microfabrication techniques to fabricate CE biochips, integrating a novel contactless conductivity detector in a miniaturized detection system in a microfluidic biochip. The off-channel electrodes are deposited around side channels by Au sputtering and patterned using a standard "lift-off" process. A vacuum fusion bonding process is employed to seal the lower substrate containing the microchannels and the electrodes to an upper glass cover plate. The variations in the capacitance between the semicircular detection electrodes in the side channels are measured as different samples and ions pass through the detection region of the CE separation channel. Samples of Rhodamine B, commercial sports drinks, mineral waters, and a red wine, respectively, are mixed in different buffer solutions, separated, and successfully detected using the developed device. The semicircular detection electrodes for the contactless conductivity detector have microscale dimensions and provide a valuable contribution to the realization of the lab-on-a-chip concept.

Conductometry↗

Electrospray from nanostructured tungsten oxide surfaces with ultralow sample volume.

This study demonstrated the feasibility of performing protein analysis with ultralow sample volume by combining a tungsten oxide nanowire (TON) fiber with a miniaturized electrospray ionization interface. An increase in wettability of the tugsten surface after growing randomly oriented TON on its surface allows strong adhesion of approximately 50 nL of the methanol solution at its tip. Under the influence of a high electric field, electrospray from a Taylor cone on the adhered methanol solution was observed and the multiply charged ions of protein molecules predissolved in the solution were detected.

Angiotensin I↗

A microfabricated capillary electrophoresis chip with multiple buried optical fibers and microfocusing lens for multiwavelength detection.

We present a new microfluidic device utilizing multiwavelength detection for high-throughput capillary electrophoresis (CE). In general, different fluorescent dyes are only excited by light sources with appropriate wavelengths. When excited by an appropriate light source, a fluorescent dye emits specific fluorescence signals of a longer wavelength. This study designs and fabricates plastic micro-CE chips capable of performing multiple-wavelength fluorescence detection by means of multimode optic fiber pairs embedded downstream of the separation channel. For detection purposes, the fluorescence signals are enhanced by positioning microfocusing lens structures at the outlets of the excitation fibers and the inlets of the detection fibers, respectively. The proposed device is capable of detecting multiple samples labeled with different kinds of fluorescent dyes in the same channel in a single run. The experimental results demonstrate that various proteins, including bovine serum albumin and beta-casein, can be successfully injected and detected by coupling two light sources of different wavelengths to the two excitation optic fibers. Furthermore, the proposed device also provides the ability to measure the speed of the samples traveling in the microchannel. The developed multiwavelength micro-CE chip could have significant potential for the analysis of DNA and protein samples.

Electrophoresis, Capillary↗

A novel microfluidic mixer utilizing electrokinetic driving forces under low switching frequency.

This paper presents a novel technique in which low-frequency periodic electrokinetic driving forces are utilized to mix electrolytic fluid samples rapidly and efficiently in a double-T-form microfluidic mixer. Without using any additional equipment to induce flow perturbations, only a single high-voltage power source is required for simultaneously driving and mixing the sample fluids which results in a simple and low-cost system for the mixing purpose. The effectiveness of the mixer as a function of the applied electric field and the periodic switching frequency is characterized by the intensity distribution calculated downstream from the mixing zone. The present numerical and experimental results confirm that the proposed double-T-form micromixer has excellent mixing capabilities. The mixing efficiency can be as high as 95% within a mixing length of 1000 microm downstream from the secondary T-junction when a 100 V/cm driving electric field strength and a 2 Hz periodic switching frequency are applied. The results reveal that the optimal switching frequency depends upon the magnitude of the main applied electrical field. The rapid double-T-form microfluidic mixer using the periodic driving voltage switching model proposed in this study has considerable potential for use in lab-on-a-chip systems.

Electrophoresis, Microchip↗

On the surface modification of microchannels for microcapillary electrophoresis chips.

This paper presents systematic investigation of the microchannel surface properties in microCE chips. Three popular materials for microCE chips, polydimethylsiloxane (PDMS), quartz, and glass, are used. The zeta potentials of these microchannels are calculated by measuring the EOF velocity to evaluate the surface properties after surface modification. The hydrophobic PDMS is usually plasma-treated for microCE applications. In this study, a new method using a high-throughput atmospheric plasma generator is adopted to treat the PDMS surface under atmospheric conditions. In this approach, the cost and time for surface treatment can be significantly reduced compared with the conventional vacuum plasma generator method. Experimental results indicate that new functional groups could be formed on the PDMS surface after treatment, resulting in a change in the surface property. The time-dependent surface property of the plasma-treated PDMS is then measured in terms of the zeta potential. Results show that the surface property will reach a stable condition after 1 h of plasma treatment. For glass CE chips, two new methods for changing the microchannel surface properties are developed. Instead of using complicated and time-consuming chemical silanization procedures for CE channel surface modification, two simple and reliable methods utilizing organic-based spin-on-glass and water-soluble acrylic resin are reported. The proposed method provides a fast batch process for controlling the surface properties of glass-based CE channels. The proposed methods are evaluated using PhiX-174 DNA maker separation. The experimental data show that the surface property is modified and separation efficiency greatly improved. In addition, the long-term stability of both coatings is verified in this study. The methods proposed in this study show potential as an excellent solution for glass-based microCE chip surface modification.

Bacteriophage phi X 174↗

Microfluidic T-form mixer utilizing switching electroosmotic flow.

This paper presents a microfluidic T-form mixer utilizing alternatively switching electroosmotic flow. The microfluidic device is fabricated on low-cost glass slides using a simple and reliable fabrication process. A switching DC field is used to generate an electroosmotic force which simultaneously drives and mixes the fluid samples. The proposed design eliminates the requirements for moving parts within the microfluidic device and delicate external control systems. Two operation modes, namely, a conventional switching mode and a novel pinched switching mode, are presented. Computer simulation is employed to predict the mixing performance attainable in both operation modes. The simulation results are then compared to those obtained experimentally. It is shown that a mixing performance as high as 97% can be achieved within a mixing distance of 1 mm downstream from the T-junction when a 60 V/cm driving voltage and a 2-Hz switching frequency are applied in the pinched switching operation mode. This study demonstrates how the driving voltage and switching frequency can be optimized to yield an enhanced mixing performance. The novel methods presented in this study provide a simple solution to mixing problems in the micro-total-analysis-systems field.

Electrochemistry↗

Band spreading control in electrophoresis microchips by localized zeta-potential variation using field-effect.

The paper proposes a new technique, which varies the zeta potential along the channel walls in the vicinity of the microchannel corners in such as a way as to minimize the effects of turn-induced dispersion within U-shaped separation channels. The effects of the separation channel geometry, the fluid velocity profile, and boundary control of the zeta potential on the band distribution in the detection area are all discussed within this paper. The results for the folded square U-shaped separation channel indicate that boundary control of the zeta potential by field-effect significantly reduces the band dispersion induced by the 90[degree] turns. Finally, the results confirm that application of the proposed localized zeta potential variation method results in a correction of the band tilting phenomenon and a reduction in the racetrack effect.

Journal Article↗

Integrated optical-fiber capillary electrophoresis microchips with novel spin-on-glass surface modification.

This paper presents a novel micro-capillary electrophoresis (CE) chip with embedded optical fibers for the on-line detection of DNA samples. The optical fibers are pre-etched and then inserted directly into fiber channels incorporated within low-cost soda-lime glass substrates. The embedded optical fibers are precisely aligned with the microfluidic channels such that the induced fluorescence signals from labeled bio-samples can be detected. This arrangement avoids the requirement for delicate optical alignment procedures and equipment. Surface modification of the CE channels is accomplished by means of a simple and reliable organic-based spin-on-glass (SOG) method. The zeta potential distribution and the corresponding electroosmotic mobility of the fluid are simulated numerically for the modified and non-modified channel surfaces, and then both sets of results are verified experimentally. The present results indicate that the value of the zeta potential for a surface with an SOG coating is 19.3 times smaller than that of an untreated surface. A phiX-174 DNA marker fluid is used to evaluate the injection and separation performance of the developed micro-CE device. Furthermore, the long-term stability of the SOG-coated surface is also investigated. The experimental data reveal that the microchip device is capable of providing highly efficient separations of bio-molecules, and that the SOG layer retains its low zeta potential characteristics for at least 45 days. The present results confirm the effectiveness of the proposed micro-CE chip in performing the on-line detection of DNA samples, and indicate that the SOG process represents a simple and reliable solution for the surface modification of glass-based microchannels.

Bacteriophages↗

Dispersion control in microfluidic chips by localized zeta potential variation using the field effect.

A new technique to minimize the effects of turn-induced dispersion within U-shaped separation channels by using the field effect within a capacitor to vary the zeta potential along the channel walls in the vicinity of the microchannel is described. The effects of the separation channel geometry, the fluid velocity profile, and the use of the field effect to control the zeta potential on the band distribution in the detection area are extensively discussed. The results for a U-shaped separation channel indicate that varying the zeta potential by controlling the field effect significantly reduces the band dispersion induced by the 90 degrees turns within the channel. Finally, it is shown that the application of the proposed localized zeta potential variation method also results in a correction of the band tilting phenomenon and a reduction in the racetrack effect.

Electromagnetic Fields↗

High-resolution DNA separation in microcapillary electrophoresis chips utilizing double-L injection techniques.

An experimental and numerical investigation into the use of high-resolution injection techniques to separate DNA fragments within electrophoresis microchips is presented. The principal material transport mechanisms of electrokinetic migration, fluid flow, and diffusion are considered, and several variable-volume injection methods are discussed. A detailed analysis is provided of a double-L injection technique, which employs appropriate electrokinetic manipulations to reduce sample leakage within the microchip. The leakage effect in electroosmotic flow (EOF) is investigated using a sample composed of rhodamine B and Cy3 dye. Meanwhile, the effects of sample leakage in capillary electrophoresis (CE) separation are studied by considering the separation of 100-base pairs (bp) DNA ladders and HaeIII-digested PhiX-174 DNA samples. The present experimental and simulation results indicate that the unique injection system employed in the current microfluidic chip has the ability to replicate the functions of both the conventional cross-channel and the shift-channel injection systems. Furthermore, applying the double-L injection method to these two injection systems is shown to reduce sample leakage significantly. The proposed microfluidic chip and double-L injection technique developed in this study have an exciting potential for use in high-resolution, high-throughput biochemical analysis applications and in many other applications throughout the micrototal analysis systems field.

DNA↗

Numerical analysis and experimental estimation of a low-leakage injection technique for capillary electrophoresis.

This paper presents an experimental and numerical investigation into the use of low-leakage injection techniques to deliver sample plugs within electrophoresis microchips. The study addresses the principal material transport mechanisms such as electrokinetic migration, fluid flow, and diffusion and gives detail analyses to the double-L injection technique, which employs electrokinetic manipulations to avoid sample leakage within the microchip. Electrical potential contour, velocity vector, and streamline distribution in the micro CE chip are successfully developed. Experimental and numerical testing results show the double-L injection technique is capable of reducing sample leakage within cross-form microfluidic chips. The current study confirms the double-L injection technique has an exciting potential for use in high-quality, high-throughput chemical analysis applications and in many other applications throughout the field of micro total analysis systems.

Journal Article↗