Optimization design of thumbspica splint using finite element method.

De Quervain's tenosynovitis is often observed on repetitive flexion of the thumb. In the clinical setting, the conservative treatment is usually an applied thumbspica splint to immobilize the thumb. However, the traditional thumbspica splint is bulky and heavy. Thus, this study used the finite element (FE) method to remove redundant material in order to reduce the splint's weight and increase ventilation. An FE model of a thumbspica splint was constructed using ANSYS9.0 software. A maximum lateral thumb pinch force of 98 N was used as the input loading condition for the FE model. This study implemented topology optimization and design optimization to seek the optimal thickness and shape of the splint. This new design was manufactured and compared with the traditional thumbspica splint. Ten thumbspica splints were tested in a materials testing system, and statistically analyzed using an independent t test. The optimal thickness of the thumbspica splint was 3.2 mm. The new design is not significantly different from the traditional splint in the immobilization effect. However, the volume of this new design has been reduced by about 35%. This study produced a new thumbspica splint shape with less volume, but had a similar immobilization effect compared to the traditional shape. In a clinical setting, this result can be used by the occupational therapist as a reference for manufacturing lighter thumbspica splints for patients with de Quervain's tenosynovitis.

De Quervain Disease↗

Biomechanical comparison of instrumented posterior lumbar interbody fusion with one or two cages by finite element analysis.

STUDY DESIGN: Using finite element models to study the biomechanics of lumbar instrumented posterior lumbar interbody fusion (PLIF) with one or two cages. OBJECTIVE: Analyzing the biomechanics of instrumented PLIF with one or two cages as to evaluate whether a single cage is adequate for instrumented PLIF. SUMMARY OF BACKGROUND DATA: Implantation of a single cage in instrumented PLIF of lumbar spine is still controversial. METHODS: Three validated finite element models of L3-L5 lumbar segment were established [intact model (INT), one cage model (LS-1), and two cages model (LS-2)]. The available finite element program ANSYS 6.0 (Swanson Analysis System Inc., Houston, TX) was applied. To analyze the biomechanics of these models, 10 Nm flexion, extension, rotation, and lateral bending moment with 150 N of preload were respectively imposed on the superior surfaces of the L3. RESULTS: Compared with the INT model, the decrease of ROM in the LS-1 and LS-2 models were exaggerated from 0.67 degrees to 3.73 degrees and ranged from 37.2% to 86.1% in all motions. The mean subsidence was found to be slightly higher in the LS-1 model. Most of the cage dislodgement in both models was less than 0.03 mm. The mean dislodgement was slightly higher in the LS-1 model. The stress of cage was found to be high in the LS-2 model. The mean stress of screw was raised to 4.5% to 9.7% in the LS-1, which was higher than that in the LS-2 model. In general, stress of adjacent disc was more pronounced in the LS-2 model. The most stress distributed at the anterior portion of the adjacent disc, which could be used to interpret the clinical findings of the early adjacent disc degeneration. CONCLUSIONS: A single cage inserted in an instrumented PLIF gains approximate biomechanical stability, slight greater subsidence, and a slight increase in screw stress but less early degeneration in adjacent disc. Adjusting these factors, instrumented PLIF with one cage could be encouraged in clinical practice.

Biomechanical Phenomena↗

Finite element analysis of the lumbar spine with a new cage using a topology optimization method.

In recent years, degenerative spinal instability has been effectively treated with a cage. However, little attention is focused on the design concept of the cage. The purpose of this study was to develop a new cage and evaluate its biomechanical function using a finite element method (FEM). This study employed topology optimization to design a new cage and analyze stress distribution of the lumbar spine from L1 to L3 with a new cage by using the commercial software ANSYS 6.0. A total of three finite element models, namely the intact lumbar spine, the spine with double RF cages, and with double new cages, were established. The loading conditions were that 10Nm flexion, extension, lateral bending, and torsion, respectively, were imposed on the superior surface of the L1 vertebral body. The bottom of the L3 vertebral body was constrained completely. The FEM estimated that the new cage not only could be reduced to 36% of the volume of the present RF cage but was also similar in biomechanical performance such as range of motion, stress of adjacent disc, and lower subsidence to the RF cage. The advantage of the new cage was that the increased space allowed more bone graft to be placed and the cage saved material. The disadvantage was that stress of the new cage was greater than that of the RF cage.

Biomechanical Phenomena↗

Finite element analysis of the spondylolysis in lumbar spine.

Spondylolysis is a fracture of the bone lamina in the pars interarticularis and has a high risk of developing spondylolisthesis, as well as traction on the spinal cord and nerve root, leading to spinal disorders or low back pain when the lumbar spine is subjected to high external forces. Previous studies mostly investigated the mechanical changes of the endplate in spondylolysis. However, little attention has been focused on the entire structural changes that occur in spondylolysis. Therefore, the purpose of this study was to evaluate the biomechanical changes in posterior ligaments, disc, endplate, and pars interarticularis between the intact lumbar spine and spondylolysis. A total of three finite element models, namely the intact L2-L4 lumbar spine, lumbar spine with unilateral pars defect and with bilateral pars defect were established using a software ANSYS 6.0. A loading of 10 N.m in flexion, extension, left torsion, right torsion, left lateral bending, and right lateral bending respectively were imposed on the superior surface of the L2 body. The bottom of the L4 vertebral body was completely constrained. The finite element models estimated that the lumbar spine with a unilateral pars defect was able to maintain spinal stability as the intact lumbar spine, but the contralateral pars experienced greater stress. For the lumbar spine with a bilateral pars defect, the rotation angle, the vertebral body displacement, the disc stress, and the endplate stress, was increased more when compared to the intact lumbar spine under extension or torsion.

Adult↗

Failure analysis of broken pedicle screws on spinal instrumentation.

Revised spinal surgery is needed when there is a broken pedicle screw in the patient. This study investigated the pedicle screw breakage by conducting retrieval analyses of broken pedicle screws from 16 patients clinically and by performing stress analyses in the posterolateral fusion computationally using finite element (FE) models. Fracture surface of screws was studied by scanning electron microscope (SEM). The FE model of the posterolateral fusion with the screw showed that screws on the caudal side had larger axial stress than those on the cephalic side, supporting the clinical findings that 75% of the patients had the screw breakage on the caudal side. SEM fractography showed that all broken screws exhibited beach marks or striations on the fractured surface, indicating fatigue failure. Screws of patients with spinal fracture showed fatigue striations and final ductile fracture around the edge. Among the 16 patients who had broken pedicle screws 69% of them achieved bone union in the bone graft, showing that bone union in the bone graft did not warrant the prevention of screw breakage.

Adult↗

Biomechanical analysis of the disc adjacent to posterolateral fusion with laminectomy in lumbar spine.

OBJECTIVES: After posterolateral fusion with laminectomy for the degenerative lumbar spine, accelerated degeneration of the disc adjacent to the fusion mass has been clinically observed. Previous studies used a finite element model (FEM) to calculate the stress of the adjacent disc in the fused lumbar spine with spinal fixator and bone graft. However, little emphasis was placed on the simultaneous spinal fusion and decompression procedure. To investigate if the spinal decompression procedure in posterolateral fusion would increase stress significantly, the FEM was employed to estimate the stress concentration of the disc above the fusion mass in posterolateral fusion with laminectomy and hemilaminectomy. METHODS: Three FEMs of the lumbar spine were established: intact spine, posterolateral fusion with total laminectomy, and posterolateral fusion with hemilaminectomy (preserved partial lamina, spinous process, and supraspinous and interspinous ligaments). The posterolateral fusion added spinal fixator and bone graft between the transverse process. The L1 vertebral body was subjected to 10-Nm flexion, extension, torsion, and lateral bending. The bottom of the L5 vertebral body was fixed. RESULTS: In flexion, the stress on the adjacent disc in posterolateral fusion with laminectomy and hemilaminectomy respectively increased 90% and 21% over that of the intact spine. In posterolateral fusion with hemilaminectomy, the supraspinous and interspinous ligaments shared some external forces to alleviate the stress concentration of the adjacent disc. However, in extension, torsion, and lateral bending, these two fusion models had almost no change in range of motion and stress of adjacent disc. CONCLUSION: Posterolateral fusion with hemilaminectomy (preserved partial lamina, spinous process, and supraspinous and interspinous ligaments) was able to alleviate the stress concentration of the disc above the fusion mass in flexion.

Biomechanical Phenomena↗

A biomechanical comparison of posterolateral fusion and posterior fusion in the lumbar spine.

Late postoperative complications occurred after posterior fusion and posterolateral fusion as a result of biomechanical alterations. The stress change between the two fusion procedures has not been well reported. To differentiate the biomechanical alteration that occurs with posterior fusion and posterolateral fusion of the lumbar spine, the load sharing of the vertebrae, disc, facet joint, bone graft, and the range of motion were computed in a finite element model. Five finite element models, including the intact lumber spine, posterior fusion, posterior fusion with implant, posterolateral fusion, and posterolateral fusion with implant, were created for stress analysis. The finite element model estimated that the differences between these two fusion procedures were within 7% in stress of the adjacent disc, 3% in force of the facet joint above the fusion mass, and 5% in the range of motion. However, the stress of the pedicle in posterolateral fusion without an implant was at most two times greater than that in the intact lumbar spine under lateral bending. The stress of pars interarticularis in posterior fusion without an implant was also at most two times greater than that in the intact lumbar spine under lateral bending. After the implant was added, the discrepancy between the two fusion procedures decreased but still remained a relatively large difference. Therefore, the largest changes of posterior fusion and posterolateral fusion were in the pars interarticularis and pedicle, respectively.

Adult↗

Biomechanical analysis of the lumbar spine with anterior interbody fusion on the different locations of the bone grafts.

The anterior lumbar interbody fusion is the common procedure in the management of the degenerated disc in the lumbar spine, but the biomechanical behavior of the fused segment would be changed because of the implantation of bone graft at the different locations. To investigate the biomechanical alteration, the study applied the finite element model to undergo the stress analysis.A three-dimensional finite element model of the lumbar spine was established, and modified to the three fusion models consisted of the bone graft at the anterior site, the middle site and the posterior site, respectively. The 12 N m flexion and the 10 N m torsion with pre-load 150 N were imposed on the L1 vertebral body. The results of the finite element model indicated that placing bone graft at anterior site could effectively resist flexion moment, and decreased the tensile force of the posterior ligaments about 15% above. Placing bone graft at posterior site could resist torsional moment, and also led to none of contact force of the facet joint in the fused segment. However, wherever the bone grafts were placed, stress slightly increased on the disc adjacent to interbody fusion about 5% below.

Bone Transplantation↗