PubMed Health⌕ Search

Biomedical subjects

Cheng S Lee

Publications and source records attributed to Cheng S Lee.

11 recordsLinked to original sources

Capillary isoelectric focusing-based multidimensional concentration/separation platform for proteome analysis.

An integrated proteome concentration/separation approach involving on-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed for providing significant analyte concentration and extremely high resolving power toward protein and peptide mixtures. Upon completion of analyte focusing, the self-sharpening effect greatly restricts analyte diffusion and contributes to analyte stacking in narrowly focused bands with a concentration factor of approximately 240. In addition to analyte focusing, CIEF as the first separation dimension resolves proteins/peptides on the basis of their differences in pI and offers greater resolving power than that achieved in strong cation exchange chromatography. The grouping of two highly resolving and completely orthogonal separation techniques of CIEF and CRPLC, together with analyte focusing and concentration, significantly enhances the dynamic range and sensitivity of conventional mass spectrometry toward the identification of low-abundance proteins. The CIEF-based multidimensional separation/concentration platform enables the identification of a greater number of yeast soluble proteins than methods presented in the literature, yet requires a protein loading of only 9.6 microg. This protein loading is 2-3 orders of magnitude lower than those employed by the reported non-gel-based proteome techniques. The distribution of a codon adaptation index value for identified yeast proteins approximates to that predicted for the entire yeast proteome and supports the capability of CIEF-based proteome separation technology for achieving comprehensive proteome analysis. By reducing the inner diameter of chromatography columns from 180 microm to 100 microm, the required protein loading is further decreased from 9.6 microg to 960 ng, illustrating the potential usage of this proteome technology for the analysis of protein profiles within small cell populations or limited tissue samples.

Chromatography, Liquid↗

Membrane-based nanoscale proteolytic reactor enabling protein digestion, peptide separation, and protein identification using mass spectrometry.

A miniaturized trypsin membrane reactor housed inside a commonly used capillary fitting is developed and demonstrated for enabling rapid and sensitive protein identification by on-line proteolytic digestion and analysis of protein digests using nano-ESI-MS and MALDI-MS. The design and assembly of the capillary fitting-based trypsin membrane reactor are straightforward and highly robust, without the need for expensive fabrication technology and procedures. The resultant protein digests can also be further concentrated and resolved using capillary reversed-phase liquid chromatography or transient capillary isotachophoresis/zone electrophoresis prior to the mass spectrometric analysis in an integrated platform. By comparing these results with the results obtained from our previous studies using plastic microfluidics (Gao et al., Anal. Chem. 2001, 73, 2648-2655), significant reduction in dead volume and sample consumption can be achieved using this newly developed tryptic digestion station. This nanoscale reaction system enables rapid proteolytic digestion in seconds instead of hours for a protein concentration of less than 10(-8) M, consumes very little sample (< or = 5 fmol), and offers capillary interfaces with various separation and mass spectrometry techniques. The ultrafast enzymatic turnover for attaining complete peptide coverage in protein identification is contributed by the highly porous structure of the membrane media, providing excessive trypsin loading while eliminating the constraints of diffusion-limited reaction kinetics.

Indicators and Reagents↗

Dynamic analyte introduction and focusing in plastic microfluidic devices for proteomic analysis.

Isoelectric focusing (IEF) separations, in general, involve the use of the entire channel filled with a solution mixture containing protein/peptide analytes and carrier ampholytes for the creation of a pH gradient. Thus, the preparative capabilities of IEF are inherently greater than most microfluidics-based electrokinetic separation techniques. To further increase sample loading and therefore the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from solution reservoirs, is demonstrated in this study. The proteins/peptides continuously migrate into the plastic microchannel and encounter a pH gradient established by carrier ampholytes originally present in the channel for focusing and separation. Dynamic sample introduction and analyte focusing in plastic microfluidic devices can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Under the influence of 30 min electrokinetic injection at constant electric field strength of 500 V/cm, the sample loading is enhanced by approximately 10-100 fold in comparison with conventional IEF.

Animals↗

Miniaturized membrane-based reversed-phase chromatography and enzyme reactor for protein digestion, peptide separation, and protein identification using electrospray ionization mass spectrometry.

A commonly used capillary fitting is employed for housing miniaturized membrane chromatography for performing reversed-phase peptide separations. By placing a hydrophobic and porous polyvinylidene fluoride membrane around the end of a polymer sleeve, the assembly of capillary fitting not only provides the stationary phase, but also establishes the necessary flow paths using capillary connections. The miniaturized membrane chromatography system is coupled with a micro-enzyme reactor containing immobilized trypsins for performing rapid protein digestion, peptide separation, and protein identification using electrospray ionization mass spectrometry. Separation performance of cytochrome c digest in miniaturized membrane chromatography is compared with the results obtained from micro-LC and capillary LC. The efficacy and the potentials of miniaturized membrane chromatography in tryptic mapping are reported. The use of miniaturized membrane chromatography allows significant reduction in sample consumption together with enhanced detection sensitivity. By minimizing the void volume in miniaturized membrane chromatography, the elution times of cytochrome c peptides are significantly shortened in this study in comparison with our previous results, and are comparable with those in micro-LC and capillary LC using considerably higher mobile phase flow-rates.

Animals↗

Extension of separation range in capillary isoelectric focusing for resolving highly basic biomolecules.

The non-availability of commercial carrier ampholytes in the pH range greater than 11 has contributed to difficulties in focusing and resolving highly basic proteins/peptides using capillary isoelectric focusing (cIEF). Two different approaches, involving the use of N,N,N',N'-tetramethylethylenediamine (TEMED) and ampholyte 9-11, are investigated for their effects on the extension of separation range in cIEF. The addition of TEMED into pharmalyte 3-10 not only prevents the peptides/proteins from focusing in sections of the capillary beyond the detection point, but also extends the separation range to at least isoelectric point (pI) 12. The combination of ampholyte 9-11 with pharmalyte 3-10 surprisingly provides baseline resolution between bradykinin (pI 12) and cytochrome c (pI 10.3). The sample mixture, containing bradykinin, the high-pI protein calibration kit (pI 5.2-10.3), and cytochrome c digest, is employed to demonstrate the cIEF separation of proteins and peptides over a wide pH range of 3.7-12.

Bradykinin↗

Gel protein capillary extraction apparatus. electronic protein transfer.

A gel protein capillary extraction apparatus is developed and demonstrated for its rapid and effective transfer of SDS-protein complexes from polyacrylamide gel to a fused-silica capillary. The small dimensions of capillary columns permit the application of high voltages for achieving rapid and effective transfer of gel proteins. Furthermore, the fused-silica capillaries are internally coated with polyacrylamide for the elimination of electroosmotic pumping and protein adsorption onto the capillary wall. The extracted proteins are present in a highly concentrated solution plug as the result of field amplification and sample stacking during the extraction process. Three model proteins, including cytochrome c (14 kDa), ovalbumin (45 kDa), and beta-galactosidase (116 kDa), are visualized using coomassie blue staining and electrophoretically extracted from the gels with protein loading as low as 50 ng. The SDS-cytochrome c complexes extracted from a 50-ng protein loading are concentrated in a 30-nL solution plug inside the capillary with an estimated concentration of 0. 1 mg/mL or 10(-5) M. The capillary format allows the straightforward integration of a miniaturized trypsin-membrane reactor for on-line proteolytic digestion and ESI-MS analysis for protein/peptide identification.

Calibration↗

On-line post-capillary affinity detection of immunoglobulin G for capillary zone electrophoresis.

To address the quality issues of antibody manufacturing, post-capillary affinity detection of immunoglobulin G (IgG) is developed for capillary zone electrophoresis. In analogy to a two-dimensional separation system, capillary zone electrophoresis (CZE), as the first dimension, resolves IgG variants based on their differences in molecular structure. IgG variants separated by CZE are discriminated against other serum and cellular proteins by affinity complex formation with protein A binding fragment in a post-capillary reactor. The analytical power of post-capillary affinity detection is demonstrated for rapid and selective heterogeneity analysis of human IgG subclasses and monoclonal antibodies in complex sample matrices. By comparing with pre-capillary formation of affinity complexes between IgG and protein A, post-capillary affinity detection clearly exhibit greater resolving power for examining IgG microheterogeneity. Affinity complex formation prior to CZE analysis, however, has the advantage of lower detection limits. Detection limits suffer with post-capillary affinity detection because of the high fluorescence background contributed by the fluorescently labeled protein A in the post-capillary reactor, and the need to determine a small change in the background level upon complex formation.

Electrophoresis, Capillary↗

High-resolution chiral separation using microfluidics-based membrane chromatography.

A plastic microfluidic system, containing porous poly(vinylidene fluoride) (PVDF) membranes adsorbed with bovine serum albumin (BSA), is demonstrated for high resolution chiral separation of racemic tryptophan and thiopental mixtures. Microfluidic networks on poly(dimethylsiloxane) (PDMS) substrates are fabricated by capillary molding technique. This miniaturized chiral separation system consists of two layers of PVDF membranes which are sandwiched between two PDMS slabs containing microchannels facing the membranes. On-line adsorption of BSA onto the membranes is employed for the preparation of chiral stationary phase and the evaluation of solution conditions in an effort to achieve maximum protein adsorption. Variations in the mobile phase conditions, including solution pH and ammonium sulfate concentration, are studied for their effects on chiral separation. Based on the large surface area to volume ratio of porous membrane media, adsorbed BSA onto the PVDF membranes enables high resolution separation of racemic mixtures with sample consumption of sub-nanogram or less in the integrated microfluidic networks. In addition, the membrane pore diameter in the submicron range eliminates the constraints of diffusional mass-transfer resistance during protein adsorption and chiral chromatographic processes.

Adsorption↗

Integration of capillary isoelectric focusing with capillary reversed-phase liquid chromatography for two-dimensional proteomics separation.

On-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed using a microinjector as the interface for performing two-dimensional (2-D) protein/peptide separations of complex protein mixtures. The focusing effect of CIEF not only contributes to a high-resolution protein/peptide separation, but also may permit the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. The preparative capabilities of CIEF are much larger than most of capillary-based electrokinetic separation techniques since the entire capillary is initially filled with a solution containing proteins/peptides and carrier ampholytes for the creation of a pH gradient inside the capillary. The focused peptides which have a similar pI are coinjected into the second separation dimension and further resolved by their differences in hydrophobicity. The resolving power of combined CIEF-CRPLC system is demonstrated using the soluble fraction of Drosophila salivary glands taken from a period beginning before steroid-triggered programmed cell death and extending to its completion. The separation mechanisms of CIEF and CRPLC are completely orthogonal and the overall peak capacity is estimated to be around approximately 1800 over a run time of less than 8 h. Significant enhancement in the separation peak capacity can be realized by further increasing the number of CIEF fractions and/or slowing the solvent gradient in CRPLC, however, at the expense of overall analysis time. The results of our preliminary studies display significant differences in the separation profiles of peptide samples obtained from salivary glands of animals staged at the 6 and 12 h following puparium formation.

Animals↗

On-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis: a two-dimensional separation system for proteomics.

A microdialysis junction is employed as the interface for on-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis in a two-dimensional separation system. Capillary isoelectric focusing not only provides high-resolution separation of tryptic peptides based on their differences in isoelectric point, but also potentially allows the analysis of low-abundance proteins with a typical concentration factor of 50-100 times. Carrier ampholytes, employed for the creation of a pH gradient during focusing, are further utilized as the leading electrolyte in the second separation dimension, transient isotachophoresis-zone electrophoresis. Many peptides which have the same isoelectric point would most likely have different charge-to-mass ratios, and thus different electrophoretic mobilities in zone electrophoresis. Two-dimensional separation of proteolytic peptides is demonstrated using standard proteins, including cytochrome c, ribonuclease A, and carbonic anhydrase II. The maximum peak capacity is estimated to be around approximately 1600 and can be significantly increased by simply increasing the capillary column length and manipulating the range of pH gradient in isoelectric focusing. In addition to enhanced separation efficiency and resolution, this two-dimensional electrokinetic separation system permits sensitive and comprehensive analysis of peptide fragments, especially when integrated with electrospray ionization mass spectrometry for peptide/protein identification.

Amino Acid Sequence↗

Dynamic enhancements of sample loading and analyte concentration in capillary isoelectric focusing for proteome studies.

Capillary isoelectric focusing (CIEF) involves the use of the entire capillary filled with a mixture containing protein/peptide analytes and carrier ampholytes. Thus, the preparative capabilities of CIEF are inherently greater than most capillary-based electrokinetic separation techniques. To further increase sample loading and, therefore, the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from a solution reservoir, is demonstrated using a low p/ protein calibration kit and tryptic peptides from Saccharomyces cerevisiae. The proteins/peptides continuously migrate into the capillary and encounter a pH gradient established by carrier ampholytes originally present in the capillary for focusing and separation. Dynamic introduction and focusing in CIEF can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Depending on the mobilities of yeast peptides, the loading capacity of each peptide is measured to be around 8 to 45-fold of that obtained in conventional CIEF. By comparing with the concentrations of dilute yeast peptides originally present in the reservoir, an overall concentration factor of 1400-7700 together with excellent separation resolution is achieved using dynamic introduction and focusing. This concentration effect is further illustrated by detecting 10 pg/microL of bradykinin peptide spiked in yeast protein digest using only ultraviolet absorption.

Chemistry Techniques, Analytical↗