Semihydrodynamic injection for high salt stacking and sweeping on microchip electrophoresis and its application for the analysis of estrogen and estrogen binding.

In this work, a semihydrodynamic (SHD) injection method was introduced and coupled with high salt stacking and electrokinetic chromatography for the analysis of estrogen and estrogen binding using a simple cross microchannel. The SHD method allows all samples to be hydrodynamically injected and focused into the separation channel at a relatively high flow rate and without splitting and diffusion, leading to reproducible bias-free injections of larger sample volumes (up to 50 nL) within 3 s. Moreover, the injection method is initiated without voltage switching, leading to a reduced mixing effect. Such advantages are well suited for performing stacking and sweeping on a microchip. We investigated the stacking effect under continuous and discontinuous co-ion conditions as well as under sweeping conditions. Micellar sweeping effect alone was relatively weak (7-8 times), partly due to a lower sodium cholate concentration (30 mM) used for the running buffer. By combining the sweeping effect with high salt stacking, however, up to a 200-300-fold enhancement factor could be achieved, and the high-salt and low-surfactant contents for the running buffer were favorable for binding study under nonequilibrium conditions. To the best of our knowledge, this is the first demonstration of the hydrodynamic injection used for high salt sample stacking on a microchip, also for further combining micellar electrochromatography and affinity separation for the analysis of hydrophobic ligand binding using microchip electrophoresis.

Binding Sites↗

Microchip electrophoresis with hydrodynamic injection and waste-removing function for quantitative analysis.

Quantitative analysis is problematic for microchip electrophoresis for several reasons including chip-to-chip variation, discontinuous sample re-loading, channel reconditioning, and electrokinetic injection bias. In this study, the capability for quantitative analysis on a flow-through based microchip electrophoresis, which provides continuous sample re-loading, channel washing, reconditioning and hydrodynamic injection as well as waste removing is demonstrated to be more quantifiable and more reproducible compared to manual electrokinetic injection method. Using the flow-through microchip with waste-removing function, FITC-labeled estrogen or Rhodamine B could be continuously analyzed without significant changes (R.S.D. < 6.6%) in signal intensity for over 3 h, which is sufficient for a complete set of quantitative analysis. With the use of a phosphorylated kinase substrate as the model, a calibration curve for quantitative analysis of phosphopeptides were constructed and results indicate that both R2 value of the linearity and R.S.D. values of the peak intensity were around 0.9961 and 3.16%, respectively, without the use of an internal standard. These values were slightly improved to be around 0.9986 and 2.27%, respectively, with the use of a non-phosphopeptide counterpart as the internal standard. The potential of this flow-through device for the development of a kinase phosphorylation assay based on the quantitative method was also briefly discussed.

Amino Acid Sequence↗