PubMed Health⌕ Search

Biomedical subjects

Cheng-Gang Niu

Publications and source records attributed to Cheng-Gang Niu.

11 recordsLinked to original sources

Fluorescence sensor for water in organic solvents prepared from covalent immobilization of 4-morpholinyl-1, 8-naphthalimide.

A new fluorescent dye, N-allyl-4-morpholinyl-1,8-naphthalimide (AMN), was synthesized as a fluorescence indicator in the fabrication of a sensor for determining water content in organic solvents. To prevent leakage of the fluorophore, AMN was photo-copolymerized with acrylamide, (2-hydroxyethyl)methacrylate, and triethylene glycol dimethacrylate on a glass surface treated with a silanizing agent. The sensing mechanism is based on the solvatochromic feature of the covalently immobilized AMN. The fluorescence intensity of AMN decreased with increasing water contents when it was excited at 400 nm. In the range of ca. 0.00-4.40% (v/v), the fluorescence intensity of AMN changed as a linear function of water content. The sensor exhibited satisfactory reproducibility, reversibility, and a response time (t (99)) of the order of 50 s. The detection limit was solvent-dependent, when acetonitrile was used as the solvent, and the detection limit could be as low as 0.006% (v/v) of water. Additionally, the prepared sensor is pH-insensitive and possesses a relatively long lifetime of at least one month.

Journal Article↗

Application of a by-product of Lentinus edodes to the bioremediation of chromate contaminated water.

The agricultural by-product of Lentinus edodes was used as a novel biosorbent for bioremediation of chromate contaminated waste water in the simulated experimental conditions. The contact time, particle size, biosorbent dosage and optimum pH range were investigated to optimize the sorption condition. The biosorption by the biomass was strongly affected by pH. At pH 1.0-2.5, all hexavalent chromium was diminished, either removed by the biosorbent or reduced to less toxic trivalent chromium even in very high concentration of 1000 mg/L. The adsorbed hexavalent chromium and reduced trivalent chromium were both linearly dependent on the initial chromium concentration. Most uptake of Cr occurred at pH around 4. The maximum uptake of chromium was 21.5 mg/g when simulated with Langmuir model, which showed the potential biosorption capacity of this biomaterial. The change of oxidation-reduction potential (ORP) during biosorption process revealed strong reduction ability of this biosorbent. Comparing analysis from Fourier transform infrared spectrums indicated that nitrogen oxide and carboxyl groups were increased after biosorption. The energy-dispersive X-ray microanalyzer revealed the mechanism of cation exchange during biosorption.

Biodegradation, Environmental↗

Fiber-optic sensor for iodine based on a covalently immobilized aminobenzanthrone Schiff base.

An aminobenzanthrone Schiff base has been synthesized as a new fluorescence carrier for the preparation of an optical chemical sensor for iodine. The response of the sensor is based on fluorescence quenching of the aminobenzanthrone Schiff base by iodine. The sensor shows a linear response toward iodine in the range of 1.0 x 10(-5) to 1.0 x 10(-3) mol l(-1), with a detection limit of 6.0 x 10(-6) mol l(-1) at pH 8.0. Leaching of the fluorophore from the membrane is effectively hindered by covalent immobilization, resulting in an enhanced sensor lifetime. In addition to satisfactory reproducibility and reversibility, the prepared sensor exhibits sufficient selectivity toward iodine with respect to other coexisting ions. The sensor has been applied to the determination of iodine in common salt samples.

Anthracenes↗

Fluorescence ratiometric pH sensor prepared from covalently immobilized porphyrin and benzothioxanthene.

A fluorescence ratiometric sensor for pH determination is described in this paper. The sensor incorporated the pH-sensitive dye meso-5,10,15,20-tetra-(4-allyloxyphenyl)porphyrin (TAPP) as an indicator and a pH-insensitive dye N-(2-methacryloxyethyl)benzo[k,l]thioxanthene-3,4-dicarboximide (MBTD), a benzothioxanthene derivative, as a reference for fluorescence ratiometric measurement. To prevent leakage of the dyes, both were photocopolymerized with acrylamide, hydroxyethyl methacrylate, and triethylene glycol dimethacrylate on the silanized glass surface. The reproducibility and response time of the prepared sensor were sufficient. Most common coexisting inorganic ions and organic compounds did not interfere with pH sensing. In the acidic pH range from 1.5 to 5.0 the fluorescence intensity ratio of the two dyes varied linearly as a function of pH. The sensing membrane was found to have a lifetime of at least one month. The sensor was applied to the analysis of waste water and artificial samples.

Acrylamide↗

A ratiometric fluorescence sensor with broad dynamic range based on two pH-sensitive fluorophores.

This paper describes a novel ratiometric fluorescence sensor for pH measurement. Two pH-sensitive fluorophores, N-allyl-4-(4'-methyl-piperazinyl)-1,8-naphthalimide (AMPN) and meso-5,10,15,20-tetra-(4-allyloxyphenyl)porphyrin (TAPP), which served as referencing indicators for each other, were co-polymerized with acrylamide, hydroxyethyl methacrylate and triethylene glycol dimethacrylate on the silanized glass surface. The proposed sensor is based on the pH-dependent fluorescence intensities of the two fluorophores in different pH ranges. The sensor covers a broad dynamic range of pH 1.5-9.0. It exhibits satisfactory analytical performance in terms of selectivity, reproducibility and stability. The successful fabrication of the proposed sensor provides an alternative concept to utilizing two or more fluorophores for the development of ratiometric sensors covering a broad range of pH.

1-Naphthylamine↗

Optochemical sensor for an ornidazole assay using 1-amino-4-allyloxyanthraquinone as a fluorescent indicator.

To improve the stability of optochemical sensors (optodes), the fluorescence indicator 1-amino-4-allyloxyanthraquinone (AAA), which was synthesized by reacting allyl bromide with 1-amino-4-hydroxyanthraquinone, was covalently immobilized on surface-modified glass slides. The resulting sensor was used to determine the content of ornidazole based on fluorescence quenching. It showed a linear response toward ornidazole in the concentration range of 9.0 x 10(-6) to 1.0 x 10(-3) mol L(-1) with a detection limit of 8 x 10(-6) mol L(-1) at pH 7.5. This AAA-immobilized sensor has a rapid response, high stability and good selectivity to ornidazole.

Anthraquinones↗

Proton "off-on" behaviour of methylpiperazinyl derivative of naphthalimide: a pH sensor based on fluorescence enhancement.

In a search for new type pH sensing fluorophores, the possibility of using the proton "off-on" switch behaviour of naphthalimide derivatives for optical pH sensor preparation has been explored. A new compound, N-allyl-4-(4[prime or minute]-methyl-piperazinyl)-1,8-naphthalimide (AMPN), was synthesized. The enhancement of fluorescence of AMPN with the increase of hydrogen ion concentration is based on arresting photo-induced electron transfer to the naphthalimide fluorophore from aliphatic amine group after its protonation. The Stokes Shift of the proposed type of pH sensing fluorophore is significantly larger than that of the fluorescein counterparts. To avoid the leakage of the fluorophore, AMPN was photo-copolymerized with 2-hydroxyethyl methacrylate and acrylamide on the glass surface. The fluorescence intensity of membrane contacted with a pH 3.50 buffer is 4.7 times of that for pH 12.00 buffer solutions. The proposed pH sensor is not susceptible to ionic strength and shows good selectivity, repeatability and short response time. The membrane shows a good stability with a lifetime over two months. The sensor can be used for the determination of pH in the range of pH 4.5-9.0, without interference of most commonly co-existing inorganic ions and some organic species. The sensor has been applied to the analysis of urine samples.

Biosensing Techniques↗

A coumarin derivative covalently immobilized on sensing membrane as a fluorescent carrier for nitrofurazone.

A coumarin derivative 4-methyl-8-methylacrylamide-2H, 5H-pyrano [3, 2-C] benzpyran 2, 5-dione (MMPBD) has been synthesized as a fluorescent carrier for preparing an optical chemical sensor. The carrier is immobilized on a quartz glass plate surface treated with a silanizing agent to prevent the leakage of the dye. This MMPBD sensor can be utilized for a nitrofurazone (NF) assay based on fluorescence quenching. The sensor shows good repeatability, a long lifetime and a fast response of less then 50 s. NF can be determined in the range between 1.0x10(-6)-1.0x10(-3 )mol L(-1) with a detection limit of 8.0x10(-7) mol L(-1 )at pH 7.0.

Coumarins↗

Carbazole as fluorescence carrier for preparation of doxycycline sensor.

Carbazole is a promising pharmaceutical species. A novel optical sensor for determining doxycycline based on the fluorescence quenching of N-allylcarbazole immobilized on an quartz glass plate surface by covalent bonding has been described. The sensor shows satisfactory virtues in reversibility, repeatability, selectivity and sufficient lifetime resulting from its excellent optode membrane. Its response time is less than 60 s. The determination range and detection limit of the sensor are 6.0 x 10(-7)-2.0 x 10(-3) M and 2.0 x 10(-7) M, respectively. The lifetime of each sensor is at least three to four months. The sensor can be used for direct determination of doxycycline in pharmaceutical preparations and urine samples.

Animals↗

N-allyl-4-(N-2'-hydroxyethyl)amino-1,8-naphthalimide as a fluorophore for optical chemosensing of nitrofurantoin.

N-Allyl-4-(N-2'-hydroxyethyl)amino-1,8-naphthalimide (AHEAN), a naphthalimide derivative, was synthesized as a new fluorophore for optical chemical sensor preparation. To prevent leakage of the fluorophore, AHEAN was photo-copolymerized with 2-hydroxypropyl methacrylate on a glass surface treated with a silanizing agent. An optical chemical sensor based on AHEAN can be utilized for nitrofurantoin assay based on fluorescence quenching. The sensor shows sufficient repeatability, selectivity and a fast response of less than 30 s. Nitrofurantoin can be determined in the range between 1.00 x 10(-6) and 1.00 x 10(-3) mol l(-1) with a detection limit of 4.8 x 10(-7) mol l(-1). Most commonly co-existing drug substances and ions do not interfere with the nitrofurantoin assay. The sensor was applied to the analysis of pharmaceutical and urine samples.

Allyl Compounds↗

Covalently immobilized aminonaphthalimide as fluorescent carrier for the preparation of optical sensors.

By replacing the hydrogen of the 4-amino group of a 4-amino-1,8-naphthalimide derivative with an N-acryloxyethyl group, the fluorophore has been covalently immobilized on an optical sensor surface by UV photopolymerization. The optical sensor obtained can be used for the determination of picric acid. The linear range and detection limit of the sensor are 9.80x10(-7)-1.96x10(-4) mol L(-1) and 7.1x10(-7) mol L(-1), respectively. Leaching of the fluorophore from the membrane is effectively prevented by covalent immobilization, resulting in a sensor with a relatively long lifetime. The response time of the sensor is short, and the reproducibility and reversibility are good. The sensor has been used for the indirect determination of the chloroquine content of pharmaceutical tablets.

Journal Article↗