PubMed Health⌕ Search

Biomedical subjects

Cheng-Huang Lin

Publications and source records attributed to Cheng-Huang Lin.

At least 19 recordsLinked to original sources

Screening of nerve agent degradation products by MALDI-TOFMS.

A novel method for the rapid screening of degradation products derived from nerve agents by matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. Five standard products were selected as model compounds, including isopropyl methylphosphonic acid (IMPA), pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), isobutyl methylphosphonic acid (i-BuMPA), and cyclohexyl methylphosphonic acid (CHMPA), which are degradation products of Sarin (GB), Soman (GD), VX, Russian VX (RVX), and GF, respectively. For comparison, CHCA (alpha-cyano-4-hydroxycinnamic acid) and DCCA (7-(diethylamino)coumarin-3-carboxylic acid) were used as the MALDI-matrix when the third harmonic generation (355 nm) of a Nd:YAG laser and a hydrogen Raman laser (multifrequency laser) were used, respectively. The method permitted the five nerve agent degradation products to be screened rapidly and successfully, suggesting that it has the potential for use as a routine monitoring tool.

Central Nervous System↗

Comparison of the use of anionic and cationic surfactants for the separation of steroids based on MEKC and sweeping-MEKC modes.

In attempts to improve the selectivity and sensitivity of steroid separation and to determine their migration order, a comparison of the use of anionic and cationic surfactants based on the MEKC and sweeping-MEKC modes was made. A mixture of six steroids (progesterone, 17-hydroxy progesterone, 11-deoxycortisol, corticosterone, cortisone, and cortisol) could be separated and detected by means of the CE/UV-absorption method. The order of migration time for these steroids was compared under various conditions, including acidic/alkaline buffers, anionic/cationic surfactants, and positive/negative applied voltage, causing the direction of the EOF and the migration of micelles to change. The major rules for generally predicting the migration order of steroids are summarized. The detection limits were significantly improved when the sweeping-MEKC mode was applied.

Anions↗

A new approach for the detection of a nonfluorescent compound by CE-resonance Raman spectroscopy based on the sweeping-MEKC mode.

A CE-resonance Raman spectroscopy (CE-RRS) method based on MEKC and sweeping-MEKC modes is described. A nonfluorescent compound, malachite green (MG), and a doubled Nd:YAG laser (532 nm, 300 mW) were selected as model compound and light source, respectively. In order to carry out a quantitative analysis of MG, a monochromator (effective bandwidth, 0.4 nm) was used to collect the specific Raman line at 1616 cm(-1) (N-phi and C-C stretch, corresponding to 582 nm when the wavelength of the exciting source was 532 nm). As a result, the LOD for MG was 10 ppm, based on the MEKC/RRS mode. This could be improved to 5 ppb when the sweeping-MEKC/RRS mode was applied. Furthermore, with the addition of nano-size silver colloids to the CE buffer the detection limits can be further improved, but the data obtained with surface-enhanced resonance Raman spectroscopy (SERRS) are less useful for quantitative purposes.

Chromatography, Micellar Electrokinetic Capillary↗

UV light-emitting diode-induced fluorescence detection combined with online sample concentration techniques for capillary electrophoresis.

The application of an ultraviolet (UV) light-emitting diode (LED) to on-line sample concentration/fluorescence detection in capillary electrophoresis (CE) is described. The utility of a UV-LED (peak emission wavelength at 380 nm, approximately 2 mW) for fluorescence detection was demonstrated by examining both a naturally fluorescent (riboflavin) compound and a nonfluorescent compound (tryptophan), respectively. The detection limit for riboflavin was determined to be 0.2 ppm by the normal MEKC mode, which was improved to 3-7 ppb when dynamic pH-junction technique was applied. On the other hand, the detection limit of the tryptophan derivative was determined to be 1.5 ppm using the MEKC mode, which was improved to 3 ppb when the sweeping-MEKC mode was applied. In an analysis of an actual sample, the concentrations of riboflavin in beer, and tryptophan in urine and milk samples were determined, respectively.

Journal Article↗

Large-volume sample sweeping with a high theoretical plate number using a coupled-capillary in capillary electrophoresis.

A large-volume sample injection (> 5 microL) with an extremely high theoretical plate number (N > 10(7)) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 microm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED ( approximately 2 mW) was used as the fluorescence excitation source. As a result, the theoretical plate numbers of the detected peaks (two model compounds: naphthalene-2,3-dicarboxaldehyde derivatized-dopamine and -norepinephrine) were 1.0 x 10(7) and 7.4 x 10(6), respectively. The limits of detection (at S/N = 3) of these were determined to be 2.8 x 10(-10) M (92 ppt) and 2.3 x 10(-10) M (83 ppt), respectively.

Journal Article↗

Optimization of the separation and on-line sample concentration of phenethylamine designer drugs with capillary electrophoresis-fluorescence detection.

Five 2C-series of phenethylamine designer drugs, including 2,5-dimethoxy-4-ethylthio-phenethylamine (2C-T-2), 2,5-dimethoxy-4-(n)-propylthiophenethylamine (2C-T-7), 4-chloro-2,5-dimethoxyphenethylamine (2C-C), 4-bromo-2,5-dimethoxy-phenethylamine (2C-B), 2,5-dimethoxy-4-iodo-phenethylamine (2C-I), were synthesized and standard GC/MS and fluorescence spectra are reported for them. A mixture of the five drugs was separated and detected by means of capillary electrophoresis (CE) with native fluorescence and light emitting diode (LED)-induced fluorescence (LIF) detection, respectively, for comparison. In the former case, exciting at a wavelength of 300 nm from a Xe lamp was used. The detection limits were found to be only in the range of approximately 10(-4) M by the micellar electrokinetic chromatography (MEKC) mode but were improved to approximately 10(-7) M when the sweeping-MEKC mode was used. For a highly sensitive analysis, LED-induced fluorescence detection was examined by derivatizing the compounds with a fluorescent dye, fluorescein isothiocyanate isomer I (FITC). A blue-LED (approximately 2 mW) was used as the fluorescence excitation source. The detection limits were improved to approximately 10(-7) and approximately 10(-8) M, respectively, when the MEKC and stacking-MEKC modes were applied. A mimic urine sample was obtained by spiking urine from a volunteer with the five standards, and after liquid-liquid extraction, the sample was examined by means of the MEKC-LIF mode. The extraction procedures used for the urine sample and the CE conditions for the separation were optimized.

Chromatography, Micellar Electrokinetic Capillary↗

Sample-stacking techniques in non-aqueous capillary electrophoresis.

In sample-stacking techniques, the detection limit cannot be improved by simply increasing the length of the sample solution, because the individual electrophoretic parameters must be optimized. In an attempt to increase the amount of sample injected, as well as to focus them onto a small zone, two novel methods are proposed. One of these employs an "ultra-high conductivity zone", which was inserted between the sample zone and background solution to build an unequal conductivity gradient. The other employs a "low temperature bath". A portion of the capillary (near the junction between the sample solution and the background solution) was immersed in a low temperature bath, which served as a "pseudo-high-conductivity zone" due to the fact that conductivity would increases when the temperature is decreased. As a result, a large volume of sample injection can be achieved. Using 3,4-methylenedioxymethamphetamine as a model compound, the detection limit was determined to be 1.6 x 10(-6) M (S/N = 3) by means of normal non-aqueous capillary electrophoresis (NACE). This could be improved to 3.0 x 10(-8) M, 4.8 x 10(-9) M and 5.0 x 10(-9) M, respectively, when the normal stacking, ultra-high conductivity zone NACE-stacking and the low-temperature zone NACE-stacking methods were applied.

Electrophoresis, Capillary↗

Methanol plug assisted sweeping-micellar electrokinetic chromatography for the determination of dopamine in urine by violet light emitting diode-induced fluorescence detection.

The use and limitations of a methanol plug assisted sweeping-micellar electrokinetic chromatography (sweeping-MEKC) method is described. Using naphthalene-2,3-dicarboxaldehyde (NDA)-labeled dopamine as a model compound, this new method was also used in the determination of dopamine in actual urine samples. An inexpensive violet light emitting diode (LED) was used for the light source, because this is suitable for fluorescence excitation. The number of theoretical plates of the analyte was determined to be approximately 1 x 10(5) and approximately 2 x 10(5) by means of MEKC and sweeping-MEKC and this was improved to approximately 1 x 10(6) when the methanol plug assisted mode was applied. In addition, the detection limit of NDA-labeled dopamine was determined to be 9.1 x 10(-7) and 1.2 x 10(-8)M by means of MEKC and sweeping-MEKC and this was improved to 4.7 x 10(-9)M when the methanol plug assisted sweeping-MEKC mode was applied.

Chromatography, Micellar Electrokinetic Capillary↗

Comparison of the use of single capillaries and coupled capillaries based on micellar electrokinetic chromatography (MEKC) and sweeping-MEKC modes.

The use of single capillaries (25 and 50 microm inner diameter (ID)) and coupled capillaries of different diameters (100-50 and 75-25 microm ID) based on micellar electrokinetic chromatography (MEKC) and sweeping-MEKC modes is compared and reported. Naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized dopamine was selected as the model compound by examining the fluorescence intensity when a violet (410 +/- 7 nm, 2 mW) light-emitting-diode (LED) was used as the light source. When a single capillary (50 microm ID) was used, the detection limit for NDA-derivatized dopamine was determined to be 2.0 x 10(-7) M (Signal-to-nose ratio S/N = 3) based on the MEKC mode. This was improved to 4.0 x 10(-9) M when the sweeping-MEKC mode was applied. In addition, this can be further improved to 1.0 x 10(-9) M and 5.6 x 10(-10) M when 100-50 and 75-25 microm ID coupled capillaries are used. The use of the coupled capillary is also helpful for improving the separation efficiency. Based on the sweeping-MEKC mode, the number of theoretical plates (N) for the detected peaks were determined to be 6.3 +/- 2.7 x 10(5) by means of a single capillary (50 microm ID). This can be improved to 9.4 +/- 3.6 x 10(5) and 9.4 +/- 0.9 x 10(6) when the 100-50 and 75-25 microm ID coupled capillaries were applied.

Chromatography, Micellar Electrokinetic Capillary↗

Comparison of the use of aqueous and nonaqueous buffers in association with cyclodextrin for the chiral separation of 3,4-methylenedioxymethamphetamine and related compounds.

A comparison of the use of aqueous and nonaqueous buffers in association with beta-CD for the chiral separation of (R)- and (S)-3,4-methylenedioxymethamphetamine and related compounds is described. The (R)- and (S)-isomers of 3,4-methylenedioxymethamphetamine (MDMA) and its major metabolite 3,4-methylenedioxyamphetamine (MDA) were prepared. Under aqueous and nonaqueous buffer conditions and based on the CZE and MEKC modes, the order of migration of (R)-MDA, (S)-MDA, (R)-MDMA, and the (S)-MDMA enantioisomers were determined. Several electrophoretic parameters, including the concentration of beta-CD (aqueous, 25-60 mM; nonaqueous, 20-150 mM) used in the electrophoretic separation and the amount of organic solvents required for the separation, were optimized.

3,4-Methylenedioxyamphetamine↗

Full-capillary sample stacking/sweeping-MEKC for the separation of naphthalene-2,3-dicarboxaldehyde-derivatized tryptophan and isoleucine.

In an attempt to improve the sensitivity of detection in capillary electrophoresis (CE), a novel online sample-concentration method, full-capillary sample stacking (FCSS)/sweeping-micellar electrokinetic chromatography (sweeping-MEKC) mode, is proposed. Naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized tryptophan and isoleucine were selected as model compounds. In the initial step, the weakly acidic compounds, dissolved in a low-conductivity buffer (35.1 microS/cm; apparent ph (pH*) in a mixed solution of acetonitrile/methanol/water, 4.6), fill the entire capillary, two vials of a high-conductivity buffer (2.06 mS/cm; pH* 2.0) are placed on each end, and a negative polarity is then applied. Under these conditions, the direction of the electroosmotic flow (EOF) is toward the inlet. Meanwhile, the anionic analytes move in the reverse direction and are neutralized and stacked at the boundary of a dynamic pH-junction (between the sample matrix and the nonmicellar background solution (BGS)). When the sample concentration is completed, the BGS is quickly changed to solutions containing SDS-BGS for the subsequent separation. Since the mobility of SDS-analytes is then greater than the EOF, the following steps occur by the sweeping (for focusing) and MEKC (for separation) mode. Using these steps, a full-capillary sample injection/separation can be achieved.

Chromatography, Micellar Electrokinetic Capillary↗

Online identification of the fluorescent whitening agent 4,4-bis(2-sulfostyrol)biphenyl using a sweeping technique combined with capillary electrophoresis/77 K fluorescence spectroscopy.

The feasibility of combining the techniques of online concentration and CE/low-temperature fluorescence spectroscopy in the detection and identification of E,E-4,4'-bis(2-sulfostyryl)biphenyl (DSBP) in synthetic detergents at 77 K is demonstrated. The technique involves the use of sweeping-MEKC, and was used for the initial online concentration and separation, after which a cryogenic molecular fluorescence experiment was performed at 77 K. The proposed method not only permits the separation and detection of E,E-DSBP in a synthetic detergent sample, but also ensures that the online spectrum is readily distinguishable and can be unambiguously assigned at 77 K. The photoconversion and isomer separation of DSBP are also described.

Biphenyl Compounds↗

Low-temperature bath/coupled-capillary/sweeping-micellar electrokinetic capillary chromatography for the separation of naphthalene-2,3-dicarboxaldehyde-derivatized dopamine and norepinephrine.

The use of a low-temperature (0 degrees C) bath-assisted coupled capillary for the separation of naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized dopamine and norepinephrine using the sweeping-micellar electrokinetic capillary chromatography (MEKC) mode is described. In this technique, a capillary consisting of two portions with different inside diameters is used. Therefore, the field strength inside the capillary is different. Hence, the electrophoretic migration velocities of the analytes and the electro-osmotic flow (EOF) also are different. Furthermore, when a portion of the capillary (wide portion, used for sweeping) is immersed in a low-temperature bath, the viscosity of the buffer and the retention factor of the analytes inside are increased. Thus, not only are the interactions between the SDS micelles and the analytes increased, but the SDS-analytes also move more slowly. As a result, a more complete separation can be achieved, even when the sample injection volume is large, up to approximately 2 microL. In general, when the volume of an injected sample is larger, the effects of sweeping and separation would become insufficient, especially when the retention values (k) of the analytes are quite different. However, this limitation can be improved when the low-temperature bath/coupled capillary/sweeping-MEKC mode is used.

Chromatography, Micellar Electrokinetic Capillary↗

The bioactivity of 2,5-dimethoxy-4-ethylthiophenethylamine (2C-T-2) and its detection in rat urine by capillary electrophoresis combined with an on-line sample concentration technique.

The bioactivity of 2,5-dimethoxy-4-ethylthiophenethylamine (2C-T-2) on nitric oxide (NO) production and the proliferation of spleen and thymus lymphocytes to mitogen stimulation in mice are reported for the first time. NO production by T and B lymphocytes in spleen and T cells in the thymus of mice decreased after the oral administration of 2C-T-2. This indicates that 2C-T-2 intake may perturb both neural and immune activity since a decrease in NO production is indicative of a weakened defense function. 2C-T-2 (the parent drug) in rat urine samples was detected by means of capillary electrophoresis/UV absorbance combined with an on-line sample concentration technique. When the CZE and MEKC modes were employed, the detection limit was found to be 4.5 and 5.0 microg/mL (at a 92.1% confidence level); whereas when on-line sample concentration methods, including stacking and sweeping-micellar electrokinetic chromatography were used, the detection limits were improved to 19.2 and 9.1 ng/mL, respectively. In an analysis of some actual samples from animal experiments, three male rats were administered 20 microg/g of body weight of 2C-T-2 by intra-peritoneal injection. The first- and second-day urine fractions were collected after the administration, for use in the analysis. As a result, 2.9 microg/mL and 0.25 microg/mL of 2C-T-2, respectively, were detected after ingestion of the doses.

Animals↗

Determination of corticosterone and 17-hydroxycorticosterone in plasma and urine samples by sweeping techniques using micellar electrokinetic chromatography.

The analysis of corticosterone in mouse blood serum (metabolic-stress experiment) and 17-hydroxycorticosterone in human urine (exercise-stress experiment) samples by means of capillary electrophoresis/UV absorbance in conjunction with online sample concentration techniques is described. The use of normal MEKC had an analyte detection limit of 7 microg/ml (S/N=3); whereas when online sample concentration methods, including sweeping-micellar electrokinetic chromatography (Sweeping-MEKC) and cation-selective exhaustive injection-sweep-micellar electrokinetic chromatography (CSEI-sweep-MEKC) were used, the detection limits could be improved to 3 and 5 ng/ml, respectively. In the analysis of actual samples from animal metabolic-stress experiments (39 mouse), chronically stressed animals showed a higher level (552+/-152 ng/ml) and acute stressed animals showed an intermediate level (375+/-105 ng/ml). In comparison, normal animals show a lower concentration level of corticosterone (153+/-109 ng/ml). In addition, based on a human exercise-stress experiment (seven volunteers), the acute stressed humans (after exercise, 800 m of running) show a higher concentration of 17-hydroxycorticosterone (113+/-55 ng/ml for males; 128+/-25 for females) and the non-stressed humans (before exercise) show a lower concentration (63+/-37 ng/ml for male; 60+/-20 for female), respectively.

18-Hydroxycorticosterone↗

On-line identification of trans-resveratrol in red wine using a sweeping technique combined with capillary electrophoresis/77 K fluorescence spectroscopy.

The feasibility of combining the techniques of on-line concentration and capillary electrophoresis/low-temperature fluorescence spectroscopy (CE/LTFS) for the detection and identification of trans-resveratrol in red wine at 77 K is demonstrated for the first time. This technique, involving sweeping-micellar electrokinetic chromatography (sweeping-MEKC), was used for the initial on-line concentration and separation, after which a cryogenic molecular fluorescence experiment was performed at 77 K. In comparison with normal-MEKC mode, a approximately 1500-fold improvement in detection sensitivity could be obtained when the sweeping-MEKC was applied. The proposed method permits not only the separation and detection of trans-resveratrol from red wine extracts but also ensures that the on-line spectrum is readily distinguishable and can be unambiguously assigned at 77 K.

Anticarcinogenic Agents↗

Stacking and low-temperature technique in nonaqueous capillary electrophoresis for the analysis of 3,4-methylenedioxymethamphetamine.

Low-temperature and ambient-temperature nonaqueous stacking techniques in capillary electrophoresis (CE) are described for the first time. A low-temperature bath was used to control the temperature from ambient to subzero degrees, by which a novel hyphenated method, low-temperature bath-nonaqueous capillary electrophoresis stacking (LTB-NACE stacking) is demonstrated. 3,4-Methylenedioxymethamphetamine (3,4-MDMA) was determined at a concentration of 4.7 x 10(-6) M (at a 92.1% confidence level) by normal nonaqueous capillary zone electrophoresis (NACZE) and this was improved to 2.6 x 10(-8) M and 5.0 x 10(-9) M, respectively, when the NACZE stacking and LTB-NACZE stacking techniques were applied. The content of 3,4-MDMA in an illicit drug and a suspect urine sample was readily detected. Upon application of the LTB to the separation of isomers the resolution (R) for the separation of 2,3-/3,4-MDMA was improved from 0.6 (LTB, 22 degrees C) to 1.6 (LTB, -55 degrees C) and for (+)3,4-MDMA/(-)3,4-MDMA, from 0.4 (LTB, 25 degrees C) to 1.0 (LTB, -10 degrees C).

3,4-Methylenedioxyamphetamine↗

On-line sample concentration techniques in capillary electrophoresis: velocity gradient techniques and sample concentration techniques for biomolecules.

Methods with a high sensitivity and high separation efficiency are goals in analytical separation techniques. On-line sample concentration techniques in capillary electrophoresis (CE) separations have rapidly grown in popularity over the past few years because they achieve this goal. This review describes the methodology and theory associated with a number of different techniques, including electrokinetic and chromatographic methods. For small molecules, several on-line concentration methods based on velocity gradient techniques are described, in which the electrophoretic velocities of the analyte molecules are manipulated by field amplification, sweeping, and isotachophoretic migration, resulting in the on-line concentration of the analyte zones. In addition, the on-line concentration methods for macromolecules are described, since the techniques used for macromolecules (DNAs and proteins), are different from those for small molecules, with respect to either mechanism or methodology. Recent studies relating to this topic are also discussed, including electrophoretic and chromatographic techniques on capillary or microchip.

DNA↗