PubMed Health⌕ Search

Biomedical subjects

Cheng-Wen Ko

Publications and source records attributed to Cheng-Wen Ko.

3 recordsLinked to original sources

Application of model-free analysis in the MR assessment of pulmonary perfusion dynamics.

Dynamic contrast-enhanced (DCE) MRI has been used to quantitatively evaluate pulmonary perfusion based on the assumption of a gamma-variate function and an arterial input function (AIF) for deconvolution. However, these assumptions may be too simplistic and may not be valid in pathological conditions, especially in patients with complex inflow patterns (such as in congenital heart disease). Exploratory data analysis methods make minimal assumptions on the data and could overcome these pitfalls. In this work, two temporal clustering methods--Kohonen clustering network (KCN) and Fuzzy C-Means (FCM)--were concatenated to identify pixel time-course patterns. The results from seven normal volunteers show that this technique is superior for discriminating vessels and compartments in the pulmonary circulation. Patient studies with five cases of acquired or congenital pulmonary perfusion disorders demonstrate that pathologies can be highlighted in a concise map that combines information of the mean transit time (MTT) and pulmonary blood volume (PBV). The method was found to provide greater insight into the perfusion dynamics that might be overlooked by current model-based analyses, and may serve as a basis for optimal hemodynamic quantitative modeling of the interrogated perfusion compartments.

Adult↗

MR ventriculocisternography by using 3D balanced steady-state free precession imaging: technical note.

This study investigated the effects of flip angle setting in 3D balanced steady-state free precession (SSFP) imaging on CSF-parenchyma contrast and section aliasing artifacts. Theoretical derivations indicated that the extent of section aliasing artifacts decreased as the flip angle was lowered, at the expense of a sacrifice in CSF-parenchyma contrast. Experimental data agreed closely with theoretical predictions. A flip angle of about 40 degrees is therefore recommended for 3D balanced SSFP MR ventriculocisternography.

Artifacts↗

Fat and water separation in balanced steady-state free precession using the Dixon method.

In this work the feasibility of separating fat and water signals using the balanced steady-state free precession (SSFP) technique is demonstrated. The technique is based on the observation (Scheffler and Hennig, Magnetic Resonance in Medicine 2003;49:395-397) that at the nominal values of TE = TR/2 in SSFP imaging, phase coherence can be achieved at essentially only two orientations (0 degrees and 180 degrees ) relative to the RF pulses in the rotating frame, under the assumption of TR << T2, and independently of the SSFP angle. This property allows in-phase and out-of-phase SSFP images to be obtained by proper choices of the center frequency offset, and thus allows the Dixon subtraction method to be utilized for effective fat-water separation. The TR and frequency offset for optimal fat-water separation are derived from theories. Experimental results from healthy subjects, using a 3.0 Tesla system, show that nearly complete fat suppression can be accomplished.

Abdomen↗