PubMed Health⌕ Search

Biomedical subjects

Chenggang Yu

Publications and source records attributed to Chenggang Yu.

2 recordsLinked to original sources

A method for automatic identification of reliable heart rates calculated from ECG and PPG waveforms.

OBJECTIVE: The development and application of data-driven decision-support systems for medical triage, diagnostics, and prognostics pose special requirements on physiologic data. In particular, that data are reliable in order to produce meaningful results. The authors describe a method that automatically estimates the reliability of reference heart rates (HRr) derived from electrocardiogram (ECG) waveforms and photoplethysmogram (PPG) waveforms recorded by vital-signs monitors. The reliability is quantitatively expressed through a quality index (QI) for each HRr. DESIGN: The proposed method estimates the reliability of heart rates from vital-signs monitors by (1) assessing the quality of the ECG and PPG waveforms, (2) separately computing heart rates from these waveforms, and (3) concisely combining this information into a QI that considers the physical redundancy of the signal sources and independence of heart rate calculations. The assessment of the waveforms is performed by a Support Vector Machine classifier and the independent computation of heart rate from the waveforms is performed by an adaptive peak identification technique, termed ADAPIT, which is designed to filter out motion-induced noise. RESULTS: The authors evaluated the method against 158 randomly selected data samples of trauma patients collected during helicopter transport, each sample consisting of 7-second ECG and PPG waveform segments and their associated HRr. They compared the results of the algorithm against manual analysis performed by human experts and found that in 92% of the cases, the algorithm either matches or is more conservative than the human's QI qualification. In the remaining 8% of the cases, the algorithm infers a less conservative QI, though in most cases this was because of algorithm/human disagreement over ambiguous waveform quality. If these ambiguous waveforms were relabeled, the misclassification rate would drop from 8% to 3%. CONCLUSION: This method provides a robust approach for automatically assessing the reliability of large quantities of heart rate data and the waveforms from which they are derived.

Algorithms↗

Classifying noisy protein sequence data: a case study of immunoglobulin light chains.

SUMMARY: The classification of protein sequences obtained from patients with various immunoglobulin-related conformational diseases may provide insight into structural correlates of pathogenicity. However, clinical data are very sparse and, in the case of antibody-related proteins, the collected sequences have large variability with only a small subset of variations relevant to the protein pathogenicity (function). On this basis, these sequences represent a model system for development of strategies to recognize the small subset of function-determining variations among the much larger number of primary structure diversifications introduced during evolution. Under such conditions, most protein classification algorithms have limited accuracy. To address this problem, we propose a support vector machine (SVM)-based classifier that combines sequence and 3D structural averaging information. Each amino acid in the sequence is represented by a set of six physicochemical properties: hydrophobicity, hydrophilicity, volume, surface area, bulkiness and refractivity. Each position in the sequence is described by the properties of the amino acid at that position and the properties of its neighbors in 3D space or in the sequence. A structure template is selected to determine neighbors in 3D space and a window size is used to determine the neighbors in the sequence. The test data consist of 209 proteins of human antibody immunoglobulin light chains, each represented by aligned sequences of 120 amino acids. The methodology is applied to the classification of protein sequences collected from patients with and without amyloidosis, and indicates that the proposed modified classifiers are more robust to sequence variability than standard SVM classifiers, improving classification error between 5 and 25% and sensitivity between 9 and 17%. The classification results might also suggest possible mechanisms for the propensity of immunoglobulin light chains to amyloid formation.

Algorithms↗