PubMed Health⌕ Search

Biomedical subjects

Chetan D Patel

Publications and source records attributed to Chetan D Patel.

5 recordsLinked to original sources

Serial radionuclide angiographic assessment of left ventricular ejection fraction and regional wall motion after mitral valve replacement in patients with rheumatic disease.

BACKGROUND: This study was designed to prospectively investigate the effects of total or partial chordal-sparing and chordal-nonsparing mitral valve replacement (MVR) procedures on regional and global ventricular function in a rheumatic population using sequential multiple-gated acquisition scan. METHODS: One hundred five consecutive patients undergoing different techniques of chordal preservation procedures during MVR are included in this prospective study. Fifteen patients had complete excision of the chordopapillary apparatus (group 1), 34 had total chordal preservation (group 2), and 56 had preservation of the posterior chordopapillary apparatus (group 3). Radionuclide-derived left ventricular ejection fraction (LVEF) and regional wall motion (RWM) studies on 99 survivors were performed preoperatively, at discharge, at 1 year, and at 2 years. RESULTS: At discharge, there was a decline in LVEF in all the 3 groups. Statistically significant improvement in ejection fraction occurred in the chordal preservation groups (2 and 3) (P < .05) as compared with the nonchordal group immediately and late postoperatively. Only the total chordal group (2) demonstrated complete recovery of LVEF by 2 years postoperatively. Significant and persistent RWM abnormalities were noted in both the nonchordal and posterior chordal groups. CONCLUSIONS: We conclude that complete retention of the chordopapillary apparatus during MVR provides superior results compared with nonchordal and partial chordal preservation in terms of preservation of LVEF and reduced incidence of abnormal postoperative RWM.

Adult↗

Noninvasive assessment of repaired tetralogy of Fallot by magnetic resonance imaging and dynamic radionuclide studies.

BACKGROUND: This study was designed to validate the diagnostic accuracy of magnetic resonance imaging (MRI) in evaluating biventricular ejection fraction and to quantify pulmonary regurgitant fraction (PRF) in patients after repair of tetralogy of Fallot. METHODS: Two hundred and eighty survivors of repaired tetralogy of Fallot aged 42 months to 40 years (mean, 142.2 +/- 85.3 months) underwent cardiac MRI, first-pass and gated radionuclide ventriculography (RNV) for the assessment of biventricular function, and PRF after 89.26 +/- 42.40 months. The receiver operating characteristic curve analysis was done to quantify the diagnostic accuracy of MRI. RESULTS: There was statistically significant agreement between MRI and RNV in evaluating right and left ventricular function. An MRI-derived right ventricular ejection fraction 47.2% or greater than normal was associated with a sensitivity of 92.3% and a specificity of 92.3%. An MRI-derived left ventricular ejection fraction 53.9% or greater than normal was associated with a sensitivity of 93.2% and a specificity of 93.3%. Area analysis indicated that 97.34% (standard error [SE] = 0.0118) and 98.56% (SE = 0.0052) of the time values of right and left ventricular ejection fraction were higher for patients with normal right and left ventricular functions, respectively, compared with abnormal. There was a strong agreement between velocity-encoded and stroke volume-derived PRF [(r = 0.886, p < 0.001; d = 2.62 +/- 1.12, p < 0.0001; r' = 0.121, p = 0.051; b = 0.96 (SE = 0.012); p < 0.0001; ICC = 0.98, p < 0.0001). Higher PRF was associated with increased indexed right ventricular dimensions and inversely correlated with biventricular ejection fractions. CONCLUSIONS: The MRI-derived ejection fraction values predictably separate patients with normal ventricular function from abnormal. Velocity-encoded MRI can accurately quantitate PRF in tetralogy of Fallot.

Adolescent↗

Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: comparison with two-dimensional echocardiography.

BACKGROUND: Rest gated 201Tl images are considered to be of poor count statistics due to lower energy and low photon flux of 201Tl in addition to increased attenuation and low dose that can be administered. We compared the left ventricular ejection fraction (LVEF), end diastolic (EDV) and end systolic volume (ESV) obtained on 4 h gated rest 201Tl myocardial perfusion single photon emission computed tomography (SPECT) with those obtained by two-dimensional echocardiography (2-D ECHO) in patients with known or suspected coronary artery disease (CAD). METHODS: Eighty-two consecutive patients who underwent gated 201Tl stress-rest myocardial perfusion SPECT and 2-D ECHO were studied. The gated thallium images were processed with Siemens e-soft autocardiac processor and LVEF, EDV and ESV were evaluated using Emory Cardiac Toolbox. The same parameters were also assessed on the 2-D ECHO using the modified Simpson method for comparison. RESULTS: Out of 82 rest gated images, one study was excluded because of poor count statistics. In 81 (99%) patients there was good linear correlation with 2-D ECHO values and rest gated 201Tl SPECT images for EDV, ESV and LVEF. Pearson's correlation co-efficient (r value) for EDV, ESV and LVEF between the two methods was 0.78, 0.79 and 0.88, respectively. A Bland-Altman plot showed close agreement with LVEF but not for EDV and ESV. CONCLUSION: These results suggest that the 4 h rest gated 201Tl study gives a reliable value for the LVEF compared to 2-D ECHO and can be used in routine clinical practice.

Adult↗

Specific issues after extracardiac fontan operation: ventricular function, growth potential, arrhythmia, and thromboembolism.

BACKGROUND: The purpose of this study was to define the prevalence of specific sequelae after extracardiac Fontan operation. METHODS: Sixty-five consecutive patients undergoing extracardiac Fontan operation were studied for mortality, Fontan failure, systemic ventricular function, supraventricular arrhythmias, thromboembolism, and growth potential. Age was 3 to 31 years (mean +/- standard deviation, 9.4 +/- 1.8; median, 7 years). The conduits were constructed of polytetrafluoroethylene (n = 50), and "viable" in situ pericardium (n = 15). The patients underwent serial echocardiogram, dynamic radionuclide studies, and cardiac catheterization. RESULTS: Operative mortality was 3%, and the incidence of conduit thrombosis was 4.6%. There was paradoxic filling of the right lung after femoral injection of the radiotracer in all cases of conduit obstruction. Perioperative and late postoperative supraventricular arrhythmias were observed in 9.2% and 4.7% of patients, respectively. Risk factors for supraventricular arrhythmias included systemic ventricular dysfunction (p = 0.000), heterotaxy syndrome (p = 0.008), systemic venous anomalies (p = 0.015), and previous bidirectional Glenn operation (p = 0.017). At a mean follow-up of 77 +/- 2 months (range, 8 to 79 months), there were no late deaths (actuarial survival at 79 months, 96.9% +/- 0.02%). Serial echocardiograms demonstrated evidence of growth of the viable tunnels. Postoperatively, there was transient depression of ejection fraction in all patients (p = 0.000). CONCLUSIONS: Supraventricular arrhythmias after extracardiac Fontan are more common in patients with heterotaxy syndrome, bilateral superior venae cavae, systemic ventricular dysfunction, and those undergoing completion Fontan operation. The viable tunnel may emerge as an optimal alternative by virtue of reduction of supraventricular arrhythmias, elimination of the need for anticoagulation, and addressing the issue of growth potential in selected patients.

Adolescent↗

Postoperative assessment of the univentricular repair by dynamic radionuclide studies.

BACKGROUND: The purpose of this investigation was to determine the role of radionuclide studies in evaluating postoperative Fontan hemodynamics and to quantify its diagnostic accuracy. METHODS: One hundred five patients (105), aged 11 months to 35 years old, who had undergone univentricular repair, underwent first-pass and multigated acquisition scan 1 month to 10 years after univentricular repair. Forty-five patients with evidence of Fontan failure underwent radionuclide studies using Technetium-99 m as well as cardiac catheterization (group 1). The remaining sixty randomly selected patients with excellent functional status received radionuclide studies alone (group 2). The receiver operating characteristic curve analysis was done to quantify the diagnostic accuracy of the first-pass study. RESULTS: There was paradoxical filling of the right lung after femoral injection in all cases of tunnel or conduit obstruction. A first-pass transit time of 16 to 25 seconds (mean +/- standard deviation [SD] = 18.82 +/- 2.69) was always associated with Fontan failure and high right atrial pressure (range = 20 to 24 mm Hg, mean +/- SD = 22.02 +/- 1.58). A first-pass transit time of 16 seconds was associated with a sensitivity of 100% and a specificity of 93.33%. The predictive accuracy of a positive or negative result was 91.8% and 100% respectively. The area measured under the receiver operating characteristic curve indicates that 99.41% (SE +/- 0.0035) of the time, the value of first-pass time is higher for the Fontan failure group (group 1) compared to the normal group (group 2; p = 0.000). CONCLUSIONS: Our data indicate that Fontan circuit can be reliably evaluated for both anatomic and functional flaws by radionuclide studies; radionuclide first-pass time may be used to predict the chances of Fontan failure postoperatively as well as its presence; and in the presence of atrial fibrillation with fast ventricular rate, analysis using first-pass radionuclide may be impossible and gated equilibrium radionuclide angiocardiography may be the preferred method. Inspection of the systemic ventricular time-activity curve is of crucial importance in this regard.

Adolescent↗