PubMed Health⌕ Search

Biomedical subjects

Chia Jung Lu

Publications and source records attributed to Chia Jung Lu.

2 recordsLinked to original sources

Chamber evaluation of a portable GC with tunable retention and microsensor-array detection for indoor air quality monitoring.

The evaluation of a novel prototype instrument designed for on-site determinations of VOC mixtures found in indoor working environments is described. The instrument contains a miniature multi-stage preconcentrator, a dual-column separation module with pressure-tunable retention capabilities, and an integrated array of three polymer-coated surface acoustic wave sensors. It was challenged with dynamic test-atmospheres of a set of 15 common indoor air contaminants at parts-per-billion concentrations within a stainless-steel chamber under a range of conditions. Vapours were reliably identified at a known level of confidence by combining column retention times with sensor-array response patterns and applying a multivariate statistical test of pattern fidelity for the chromatographically resolved vapours. Estimates of vapour concentrations fell within 7% on average of those determined by EPA Method TO-17, and limits of detection ranged from 0.2 to 28 ppb at 25 degrees C for 1 L samples collected and analyzed in <12 min. No significant humidity effects were observed (0-90% RH). Increasing the chamber temperature from 25 to 30 degrees C reduced the retention times of the more volatile analytes which, in turn, demanded alterations in the scheduling of column-junction-point pressure (flow) modulations performed during the analysis. Reductions in sensor sensitivities with increasing temperature were predictable and similar among the sensors in the array such that most response patterns were not altered significantly. Short-term fluctuations in concentration were accurately tracked by the instrument. Results indicate that this type of instrument could provide routine, semi-autonomous, near-real-time, multi-vapour monitoring in support of efforts to assess air quality in office environments.

Air Pollution, Indoor↗

Multi-adsorbent preconcentration/focusing module for portable-GC/microsensor-array analysis of complex vapor mixtures.

A small multi-adsorbent preconcentration/focusing module for a portable GC with microsensor-array detector designed to determine complex mixtures of volatile and semi-volatile organic compounds encountered in indoor working environments is described. Candidate adsorbents were assessed on the basis of analyte thermal-desorption bandwidth and efficiency, chromatographic peak shape, and breakthrough volume against mixtures of organic compounds ranging over four orders of magnitude in vapor pressure. A capillary packed with just 12.3 mg of adsorbent material comprising Carbopack B (8 mg), Carbopack X (2.5 mg) and Carboxen 1000 (1.8 mg) provided the best tradeoff in operating variables, while maintaining sufficient capacity for a 1 L air sample containing a mixture of up to 43 compounds, each at 100 parts-per-billion, at an ambient relative humidity of up to 100%. On-column focusing and temperature programming were used to enhance chromatographic separations, and detection limits as low as 100 parts-per-trillion were achieved for a 1 L air sample using an integrated array of polymer-coated surface-acoustic-wave (SAW) sensors. Implications for field analysis of indoor air quality are emphasized.

Acoustics↗