PubMed Health⌕ Search

Biomedical subjects

Chien-Hsiung Tsai

Publications and source records attributed to Chien-Hsiung Tsai.

6 recordsLinked to original sources

Rapid circular microfluidic mixer utilizing unbalanced driving force.

This paper proposes a novel rapid circular microfluidic mixer for micro-total-analysis-systems (mu-TAS) applications in which an unbalanced driving force is used to mix fluids in a circular chamber at low Reynolds numbers (Re). The microfluidic mixer has a three-layered structure and is fabricated on low-cost glass slides using a simple and reliable fabrication process. Using hydrodynamic pumps, fluids are driven from two inlet ports into a circular mixing chamber. Each inlet port separates into two separate channels, which are then attached to opposite sides of the 3-dimensional (3-D) circular mixing chamber. The unequal lengths of these inlet channels generate an unbalanced driving force, which enhances the mixing effect in the mixing chamber. Numerical simulations are performed to predict the fluid phenomena in the mixing chamber and to estimate the mixing performance under various Reynolds number conditions. The numerical results are verified by performing flow visualization experiments. A good agreement is found between the two sets of results. The numerical and experimental results reveal that the mixing performance can reach 91% within a mixing chamber of 1 mm diameter at a Reynolds number of Re=3. Additionally, the results confirm that the unbalanced driving force produces a flow rotation in the circular mixer at low Reynolds numbers, which significantly enhances the mixing performance. The novel micromixing method presented in this study provides a simple solution for mixing problems in Lab-on-a-chip systems.

Chemistry Techniques, Analytical↗

Optimal configuration of capillary electrophoresis microchip with expansion chamber in separation channel.

This study develops a novel capillary electrophoresis (CE) microfluidic device featuring a conventional cross-form injection system and an expansion chamber located at the inlet of the separation channel. The combined injection system/expansion chamber arrangement is designed to deliver a high-quality sample band into the separation channel such that the detection performance of the device is enhanced. Numerical simulations are performed to investigate the electrokinetic transport processes in the microfluidic device and to establish the optimal configuration of the expansion chamber. The results indicate that an expansion chamber with an expansion ratio of 2.5 and an expansion length of 500 microm delivers a sample plug with the correct shape and orientation. With this particular configuration, the peak intensities of the sample are sharp and clearly distinguishable in the detection region of the separation channel. Therefore, this configuration is well suited for capillary electrophoresis applications which require a highly sensitive resolution of the sample plug. The novel CE microfluidic device developed in this study has an exciting potential for use in high-performance, high-throughput chemical analysis applications and in many other applications throughout the field of micro-total-analysis-systems.

Electrophoresis, Microchip↗

Micromixer utilizing electrokinetic instability-induced shedding effect.

This paper presents a T-shaped micromixer featuring 45 degrees parallelogram barriers (PBs) within the mixing channel. The presented device obtains a rapid mixing of two sample fluids with conductivity ratio of 10:1 (sample concentration:running buffer concentration) by means of the electrokinetic instability-induced shedding effects which are produced when a direct current (DC) electric field of an appropriate intensity is applied. The presented device uses a single high-voltage power source to simultaneously drive and mix the sample fluids. The effectiveness of the mixer is characterized experimentally as a function of the applied electrical field intensity and the extent to which the PBs obstruct the mixing channel. The experimental results indicate that the mixing performance reaches 91% at a cross-section located 2.3 mm downstream of the T-junction when the barriers obstruct 4/5 of the channel width and an electrical field of 300 V/cm is applied. The micromixing method presented in this study provides a simple low-cost solution to mixing problems in lab-on-a-chip systems.

Equipment Design↗

Experimental and numerical investigation into leakage effect in injectors of microfluidic devices.

This paper performs an experimental and numerical investigation into low-leakage injectors designed for electrophoresis microchips. The principal material transport mechanisms of electrokinetic migration, fluid flow, and diffusion are considered in developing a mathematical model of the electrophoresis process. Low-leakage injectors designed with injection channels orientated at various included angles are designed and tested. The numerical and experimental results indicate that the injector with a 30 degrees included angle successfully minimizes sample leakage and has an exciting potential for use in high-quality, high-throughput chemical analysis procedures and in many other applications in the field of micro-total analysis systems.

Computer Simulation↗

Application of electrokinetic instability flow for enhanced micromixing in cross-shaped microchannel.

This paper proposes a cross-shaped micromixer featuring a pair barrier within the mixing channel. The proposed device obtains a rapid mixing of two sample fluids by means of the electrokinetic instability-induced shedding effects which are produced when a DC electric field of an appropriate intensity is applied. The proposed device uses a single high-voltage power source to simultaneously drive and mix the sample fluids. The effectiveness of the mixer is characterized experimentally as a function of the applied electric field intensity and the extent to which a pair barrier obstruct the mixing channel. The experimental results indicate that the mixing performance reaches 96% at a cross-section located 1 mm downstream of the cross-junction when an electric field of 300 V/cm is applied. The micromixing method presented in this study provides a simple low-cost solution to mixing problems in lab-on-a-chip systems.

Kinetics↗

Numerical simulation of electrokinetic injection techniques in capillary electrophoresis microchips.

The effective design and control of a capillary electrophoresis (CE) microchip requires a thorough understanding of the electrokinetic transport phenomena associated with its microfluidic injection system. The present study utilizes a numerical simulation approach to investigate these electrokinetic transport processes and to study the control parameters of the injection process. Injection systems with a variety of different configurations are designed and tested, including the cross-form, T-form, double-T-form, variable-volume focused flow cross-form, and variable-volume triple-T-form configuration. Each injection system cycles through a predetermined series of steps in which the magnitudes and distributions of the applied electric field are precisely manipulated in order to effectuate a virtual valve. This study investigates the sample leakage effect associated with each of the injection configurations and applies the double-L, pullback, and focusing injection techniques to minimize the sample leakage effect. The injection methods presented in this paper have the exciting potential for use in high-quality, high-throughput chemical analysis applications and throughout the micro-total-analysis systems field.

Electrophoresis, Microchip↗