Aerodynamics and performance verifications of test methods for laboratory fume cupboards.

The laser-light-sheet-assisted smoke flow visualization technique is performed on a full-size, transparent, commercial grade chemical fume cupboard to diagnose the flow characteristics and to verify the validity of several current containment test methods. The visualized flow patterns identify the recirculation areas that would inevitably exist in the conventional fume cupboards because of the fundamental configurations and structures. The large-scale vortex structures exist around the side walls, the doorsill of the cupboard and in the vicinity of the near-wake region of the manikin. The identified recirculation areas are taken as the 'dangerous' regions where the risk of turbulent dispersion of contaminants may be high. Several existing tracer gas containment test methods (BS 7258:1994, prEN 14175-3:2003 and ANSI/ASHRAE 110:1995) are conducted to verify the effectiveness of these methods in detecting the contaminant leakage. By comparing the results of the flow visualization and the tracer gas tests, it is found that the local recirculation regions are more prone to contaminant leakage because of the complex interaction between the shear layers and the smoke movement through the mechanism of turbulent dispersion. From the point of view of aerodynamics, the present study verifies that the methodology of the prEN 14175-3:2003 protocol can produce more reliable and consistent results because it is based on the region-by-region measurement and encompasses the most area of the entire recirculation zone of the cupboard. A modified test method combined with the region-by-region approach at the presence of the manikin shows substantially different results of the containment. A better performance test method which can describe an operator's exposure and the correlation between flow characteristics and the contaminant leakage properties is therefore suggested.

Air Movements↗

(PS)2: protein structure prediction server.

Protein structure prediction provides valuable insights into function, and comparative modeling is one of the most reliable methods to predict 3D structures directly from amino acid sequences. However, critical problems arise during the selection of the correct templates and the alignment of query sequences therewith. We have developed an automatic protein structure prediction server, (PS)2, which uses an effective consensus strategy both in template selection, which combines PSI-BLAST and IMPALA, and target-template alignment integrating PSI-BLAST, IMPALA and T-Coffee. (PS)2 was evaluated for 47 comparative modeling targets in CASP6 (Critical Assessment of Techniques for Protein Structure Prediction). For the benchmark dataset, the predictive performance of (PS)2, based on the mean GTD_TS score, was superior to 10 other automatic servers. Our method is based solely on the consensus sequence and thus is considerably faster than other methods that rely on the additional structural consensus of templates. Our results show that (PS)2, coupled with suitable consensus strategies and a new similarity score, can significantly improve structure prediction. Our approach should be useful in structure prediction and modeling. The (PS)2 is available through the website at http://ps2.life.nctu.edu.tw/.

Amino Acid Sequence↗

Correlation between airflow patterns and performance of a laboratory fume hood.

To understand the physical mechanisms of the contaminant dispersion and containment leakage during the ventilation process through a laboratory fume hood, the complicated three-dimensional flow patterns and the real-time tracer gas (SF6) leakage were studied via the laser-assisted flow visualization method and the standard/special gas sampling technique, respectively. Through flow visualization, the large-scale vortex structures and boundary layer separations were found around the side poles and doorsill of the hood. In the near-wake region of the manikin, large recirculation zones and wavy flow structures were also identified. When tracer gas concentration measurements were conducted point-by-point across the sash opening, the areas near the doorsill, the lower parts of the side poles, and the sides of the manikin showed significant contaminant leaks. These areas with high contaminant leaks exactly corresponded to where the flow recirculated or separated. However, when the ANSI/ASHRAE 110-1995 protocol was used to measure the concentration of SF6 at the breathing zone of the manikin, no appreciable leakage was detected. It is suggested that a method based on the aerodynamic features and multipoint leakage detections would reflect a more realistic evaluation of overall performance of laboratory fume hood than a single-point sampling method at the manikin's breathing zone.

Air Movements↗

Evaluation of exhalation valves.

Certification tests currently employed by some industrialized nations to certify respirators require that when challenged with air flow at a constant suction head of 25 mmH2O, the leakage into the facepiece from the exhalation valve(s) should not exceed 30 ml min(-1). However, the test alone might not reflect the leakage rate under different levels of vacuum. To study the characteristics of leakage through exhalation valves, a leakage meter was built to measure the leakage rate of four brands of exhalation valves. Seven valves of each brand were tested for leakage rate at pressure drops ranging from 15 to 45 mmH2O (or extended to 75 mmH2O for some valves). Two types of leaks, i.e. fiber insertion and arch dent on the valve seat, were used to investigate the effect of leak shape on the characteristic leak flow as a function of pressure drop. A leakage data point represented a mean value of five measurements. The results showed that the leakage rate could increase or decrease with increasing pressure drop inside the respirators, indicating that the current method of conducting leakage tests, at a constant suction head of 25 mmH2O, does not guarantee better protection than when the respirators are used at a lower suction head. Moreover, based on the sample valves tested in this study, it was found that valve leakage was mostly caused by defects in the valve seats. Both fiber-insertion and arch-dent leaks had either increasing or decreasing characteristic curves, depending on the size of the leak and the material of the valve membrane.

Data Collection↗

Effects of flange size on dividing streamlines of exterior hoods in cross drafts.

Effects of flange size on the flow patterns of an exterior circular hood subject to the influence of various uniform cross drafts were studied in an apparatus consisting of hood-model/wind-tunnel assembly. The cross draft to suction velocity ratio covered the range from 0.056 to 0.792. The flange width to hood diameter ratio spanned from 1.2 to 3.0. The hood equipped without flange was also probed. A two-component laser Doppler anemometer was used to measure the velocity field on the symmetry plane. The streamline patterns were obtained from the measured velocity data. The cross draft caused a capture envelope. The boundary of the envelope was described by a dividing streamline. It was found that the flange width presented complex effects on the capture envelope and the dividing streamline. Corresponding to a cross draft to suction velocity ratio, a critical flange width existed. If the flange width was smaller than the critical value, the dividing streamline would terminate at the downstream tip of the flange. The behaviors of the capture envelope and the dividing streamline of the hood in cross draft under different flange widths are presented and discussed.

Air Movements↗

Ultrafine aerosol penetration through electrostatic precipitators.

This work measures the penetration of ultrafine particles through a single-stage and a two-stage ESP as a function of particle size. Also studied herein are how parameters including particle size, rate of airflow through the ESP, and voltage of the discharging electrode affect aerosol penetration through the ESP. Monodisperse particles with sizes between 10 and 60 nm were generated as the challenge aerosols to investigate the particle charges given by an ESP. A comparison of experimental and theoretical results confirms that a partial charging regime exists when the particle diameter is several tens of nanometers. Experimental results indicated that aerosol penetration through the single- and two-stage ESPs increased significantly for particles below 20 and 50 nm, respectively. However, the exact regime depends on the parameters including airflow rate, applied voltage, and configuration of the ESP. Phenomena such as ionic flow, particle space charge, and flow turbulence may significantly affect the collection efficiency of an ESP for ultrafine particles. To achieve the same collection efficiency, it is more economical to use single-stage ESPs to collect particles less than 16 nm from the standpoint of energy consumption. However, it is more economical to use two-stage ESPs to collect particles larger than 16 nm.

Aerosols↗

Suspended onion particles and potential corneal injury in onion harvesters.

The authors suspected that suspended onion particles contributed to corneal ulcers in onion harvesters in southern Taiwan. In the present study, the authors used manikins to study suspended onion particles in fields in an effort to simulate typical conditions experienced by onion harvesters. An animal eye-exposure simulation study was also performed by the authors, who impacted suspended soil grains or onion particles onto the corneas of guinea pigs via aerosol generated from the Palas dispersion nozzle. The average size of 25.9 pm for suspended particles collected during the digging of onions was the largest one of those for various harvesting activities. Some onion skin flakes were found in samples obtained from gathering and packing activities; the typical flake size was approximately 3.5 x 2.5 mm2. The results of the animal study indicated that the size of soil grains has a demonstrable effect on the severity of corneal injury (p = .009). With respect to onion skin flakes, wind velocity was also associated significantly with the occurrence of corneal injury (p = .0004). A wind velocity threshold of 7 m/sec is recommended for the maintenance of safety, and if the wind speed exceeds this threshold level, workers should not engage in harvesting activities. Furthermore, use of appropriately designed goggles is necessary for the protection of onion harvesters who work in high-wind conditions.

Agricultural Workers' Diseases↗