PubMed Health⌕ Search

Biomedical subjects

Chih-Hao Lin

Publications and source records attributed to Chih-Hao Lin.

10 recordsLinked to original sources

The demand for prehospital advanced life support and the appropriateness of dispatch in Taipei.

INTRODUCTION: Implementing prehospital advanced life support (ALS) services requires more medical and societal resources in training and equipment. The actual demand for ALS services in our communities was not clear. To ensure good use of expensive resources, it is important to evaluate the demand and appropriateness of ALS services before full-scale implementation takes place. OBJECTIVE: To evaluate the rate and characteristics of demand for ALS, and the appropriateness of ALS dispatch of the emergency medical service (EMS) system in metropolitan Taipei City. METHODS: A retrospective, cross-sectional analysis of the EMS records of Taipei City Fire Department from April 1999 to December 2000 was conducted. Stratified random sampling of all EMS records in the second week of January, April, July and October of 2000 were obtained, along with the corresponding ALS dispatch records. Retrospective ALS demand criteria, including the chief complaints, mechanisms of injury/illness, initial vital signs and types of care rendered, were developed to estimate the rate of ALS demand. ALS demand is expressed as the percentage of cases fulfilling ALS criteria over the total number of EMS cases. Appropriate ALS dispatches were those ALS dispatches determined as fulfilling the ALS demand criteria. RESULTS: Among the sampled 5433 EMS cases, 490 (9.02%) were determined as a demand for ALS care. ALS demands varied from region to region, and were higher during winter months and afternoon rush hours. There were 175 actual ALS dispatches, accounting for 3.22% of the sampled EMS services. The triage performance was suboptimal: the appropriateness of ALS dispatch was 37.14%; the overtriage rate was 72.86%. CONCLUSION: Around nine percent of EMS calls demand ALS services. The current triage performance for proper ALS dispatch was suboptimal. A correct ALS dispatch protocol and more dispatcher training programmes should be established in the communities to ensure best use of valuable ALS resources.

Advanced Cardiac Life Support↗

Acute renal failure caused by mushroom poisoning.

Despite the abundance of wild mushrooms growing in a variety of habitats in Taiwan, mushroom poisoning is rarely reported. Here, we report two cases of mushroom poisoning, possibly due to Amanita smithiana or a related species. A 54-year-old man and his 52-year-old wife presented with acute anuric renal failure 1 day after ingesting some white mushrooms they had collected when mountain climbing; they made a full recovery following hemodialysis and supportive treatment. Although rare, mushroom poisoning should be considered in the differential diagnoses of acute renal failure.

Acute Kidney Injury↗

Evaluating the quality of prehospital cardiopulmonary resuscitation by reviewing automated external defibrillator records and survival for out-of-hospital witnessed arrests.

OBJECTIVES: Without an easy method to monitor the performance of prehospital cardiopulmonary resuscitation (CPR), earlier studies have not been able to assess the quality of CPR. In this study, we have used a new approach to evaluate prehospital CPR performance and the impact on outcome using data retrieved from the automatic external defibrillators (AED). MATERIALS AND METHODS: Electrocardiography (ECG) and voice records from AED data cards from 633 out-of-hospital cardiac arrests (OHCA) were reviewed. Fifty-two witnessed cardiac arrests in ventricular fibrillation (VF) requiring post-shock CPR underwent an independent, structured review by two physicians. The adequacy of prehospital CPR was defined on the basis of noticeable deflection of the ECG with chest compressions, the actual number of chest compressions delivered per minute, and the continuity of prehospital CPR at the scene and during transport. Outcome measures included return of spontaneous circulation (ROSC) and survival to hospital admission and discharge. RESULTS: The quality of prehospital CPR was judged as adequate in 15 (29%, 95%; CI: 18-42%) and inadequate in 37 (71%, 95%; CI: 58-82%) of the consensus. Adequate CPR performance resulted in a higher rate of ROSC at the scene (53% versus 8%, 95% CI of the difference 14-76%), and survival to hospital discharge (53% versus 8%, 95% CI of the difference 14-76%). Two reviewers agreed on whether CPR was adequate in 92.3% of cases, with a kappa of 0.82. CONCLUSIONS: The quality of prehospital CPR is associated with a greater likelihood of survival in witnessed VF arrests in need of post-shock CPR. The potential of widely available electrocardiography and voice records in AEDs in providing a convenient and real-time evaluation of prehospital CPR should be explored further.

Adolescent↗

Better adherence to the guidelines during cardiopulmonary resuscitation through the provision of audio-prompts.

OBJECTIVE: Quality assurance to optimize clinical resuscitation performance is important. The aims of the present study were to identify the deficiencies in the clinical practice of resuscitation by motion analysis of video-recorded cardiopulmonary resuscitation (CPR), and to evaluate the effectiveness of quality improvement strategies based on audio-prompt methods. MATERIALS AND METHODS: A two-stage prospective trial was conducted. The first stage (observation group) was designed to identify any major clinical nonconformity to current resuscitation guidelines by videotaped CPR sessions. The second stage (intervention group) was designed to evaluate the effectiveness of audio prompts in ameliorating the problems identified at the first stage. The demographic data of patients and CPR variables between the two groups were analysed. RESULTS: A total of 30 resuscitation attempts were recorded during study period: 17 patients were in the observation group and 13 patients in the intervention group. Inadequate number of chest compressions per minute, lack of re-oxygenation during prolonged intubation attempts and unnecessary hands-off periods were identified as the three most important deficiencies in CPR practice. Compared to the observation group, the intervention group showed a significant improvement in the hands-off period per minute during CPR (12.7 +/- 5.3 s versus 16.9+/-7.9 s, P < 0.05), the total hands-off time during CPR (164 +/- 94 s versus 273 +/- 153 s, P < 0.05), the proportion of intubation attempts taking under 20 s (56.3% versus 10%, P < 0.05). CONCLUSIONS: Audio-prompts can improve the adherence to current CPR guidelines in the clinical setting significantly. The quality improvement measures described in this study are helpful in translating CPR knowledge into clinical practice.

Adult↗

Machine and operator performance analysis of automated external defibrillator utilization.

BACKGROUND AND PURPOSE: The availability of an automated external defibrillator (AED) can improve the outcome of patients with out-of-hospital cardiac arrest (OHCA). On June 1, 2000, Taipei City became the first city in Taiwan to equip emergency medical services personnel with AEDs. This study was conducted to assess the performance of the AED machine in detecting ventricular fibrillation (VF) and ventricular tachycardia (VT) in the population, and to assess operator performance in its use. METHODS: AED use in OHCA patients was assessed over a 1-year period. Electrocardiography and voice records retrieved from AED data cards were analyzed. A shockable rhythm was defined as either VF or VT. AED machine performance was assessed based on the correct identification of these rhythms. Operator performance was evaluated according to American Heart Association guidelines. RESULTS: A total of 978 AED rhythm analyses were obtained for 653 OHCA patients. The sensitivity and specificity for detecting shockable rhythms by the AED machine were 90.0% (95% confidence interval [CI], 85.3% to 93.3%) and 100% (95% CI, 99.5% to 100%), respectively. Sensitivity for coarse VF, fine VF, rapid VT, and slow VT was 97.5%, 74.2%, 63.6% and 60.0%, respectively. An AED was deployed in 18 non-OHCA patients and in 119 patients after they had been moved into the ambulance. Non-compliance with standard procedures occurred during AED use in 162 patients, including interference of movement by cardiopulmonary resuscitation (CPR) in progress in 69, untimely machine turn-off in 49, leads fell off or disconnected in 33, failure of shock delivery after charge in 28, and interference of movement other than CPR in 22. CONCLUSIONS: This study found that the AED machine has high specificity and high sensitivity in detecting VF and VT, especially coarse VF. Efforts are needed to improve the timing of AED deployment and emergency medical technician compliance with standard procedures.

Adolescent↗

Near-fatal methemoglobinemia after recreational inhalation of amyl nitrite aerosolized with a compressed gas blower.

Adverse effects associated with recreational inhalation of nitrites are usually mild and rarely life-threatening. We report a rare case of near-fatal methemoglobinemia after inhalation of amyl nitrite after aerosolizing the liquid using a compressed gas blower designed to clean photographic equipment that employed hydrofluoroalkane-134a as a propellant. A 31-year-old previously healthy male became dyspneic and fainted soon after the recreational inhalation of amyl nitrite aerosolized using a compressed gas blower. He was brought to the emergency department with severe cyanotic appearance and profound shock. Oxygen saturation was 82%, unresponsive to oxygen supply. His methemoglobin blood level was 52.2%. After 100 mg of methylene blue (2 mg/kg body weight) was administered intravenously, he recovered consciousness, and dyspnea and cyanosis subsided gradually. This case illustrates the extraordinary hazard of the use of a compressed gas blower in the recreational inhalation of nitrites. Prompt recognition and rapid antidotal treatment may adequately correct near-fatal overdose associated with recreational use of amyl nitrite.

Adult↗