PubMed Health⌕ Search

Biomedical subjects

Chinlon Lin

Publications and source records attributed to Chinlon Lin.

6 recordsLinked to original sources

Optical label switching of DRZ/DPSK orthogonal signal generated by photonic-crystal fiber.

We demonstrate orthogonal label switching by using a dark-return-to-zero (DRZ) payload and differential phase-shift keying (DPSK) label generated by a dispersion-flattened photonic-crystal fiber. The high extinction ratio of both the payload and label improves the receiver margin. The DRZ payload introduces little cross talk to the DPSK label due to the RZ-like output of the demodulated DPSK. Simulations are performed to study the eye-closure penalty of the payload and label at different DRZ pulse widths. We compare the DRZ/DPSK with the RZ and DPSK signals numerically at the same data rate and show that the DRZ/DPSK has a strong tolerance to the polarization-mode dispersion. The DRZ/DPSK has a more compact spectrum suitable for the strong filtering requirements in WDM systems.

Journal Article↗

Application of two-dimensional spectral surface plasmon resonance to imaging of pressure distribution in elastohydrodynamic lubricant films.

What we believe to be a novel two-dimensional spectral surface plasmon resonance imaging technique determining pressure distribution in elastohydrodynamic lubricant films is presented. This technique makes use of the spectral characteristics associated with the surface plasmon resonance (SPR) effect, and it provides more spectral information in refractive index mapping than conventional contrast SPR imaging. Two-dimensional imaging is demonstrated and applied to a highly pressurized liquid lubricant trapped inside an elastohydrodynamic lubrication (EHL) dimple. The hydrostatic pressure inside the EHL dimple causes a localized change of the refractive index of the lubrication oil. This also results in a shift in the spectral SPR absorption dip. By monitoring the color changes within the SPR image and calibrating with lubricants of known refractive index profiles, we can obtain a direct measurement of the refractive index distribution within the EHL dimple. PB 2400 lubricant dimples were studied in our experiments. The proposed SPR imaging approach is irrespective of the absolute lubricant film thickness h, therefore overcoming the major limitations of a conventional optical interference technique. With further development of the two-dimensional refractive index mapping technique, widespread applications in various fields are possible, including high-throughput sensors and the detection of bioaffinity interactions.

Journal Article↗

Nonlinear polarization rotation in a dispersion-flattened photonic-crystal fiber for ultrawideband (>100 nm) all-optical wavelength conversion of 10 Gbit/s nonreturn-to-zero signals.

We study the conversion bandwidth of the cross-polarization-modulation (XPoIM)-based wavelength conversion scheme with a dispersion-flattened highly nonlinear photonic-crystal fiber for signals with a nonreturn-to-zero (NRZ) modulation format. Both theoretical and experimental results show that the conversion bandwidth can be extended to cover a very wide band, including S-, C-, and L-bands for 10 Gbit/s NRZ signals (a total bandwidth of 120 nm is experimentally demonstrated). We also study the theoretical bandwidth limit for 40 Gbit/s NRZ signals. A significant extension of the conversion bandwidth using the XPoIM approach compared with the four-wave mixing approach previously reported is demonstrated.

Journal Article↗

Real-time optical biosensor based on differential phase measurement of surface plasmon resonance.

We report a real-time differential phase measurement technique which can be implemented in optical surface plasmon resonance biosensors. The important feature of our design is that sensitivity has been greatly improved by measuring the differential phase change between the s and p-polarizations. Real-time measurement capability is achieved by using a phase extracting routine which continuously monitors the waveforms captured by two photo-detectors. Measurement capability of our setup is demonstrated through real-time monitoring of bovine serum albumin (BSA)/anti-BSA binding reaction. The estimated sensitivity of our current setup is 7.4 ng/ml.

Biosensing Techniques↗

Highly sensitive differential phase-sensitive surface plasmon resonance biosensor based on the Mach-Zehnder configuration.

A high-sensitivity surface plasmon resonance (SPR) biosensor based on the Mach-Zehnder interferometer design is presented. The novel feature of the new design is the use of a Wollaston prism through which the phase quantities of the p and s polarizations are interrogated simultaneously. Since SPR affects only the p polarization, the signal due to the s polarization can be used as the reference. Consequently, the differential phase between the two polarizations allows us to eliminate all common-path phase noise while keeping the phase change caused by the SPR effect. Experimental results obtained from glycerin-water mixtures indicate that the sensitivity limit of our scheme is 5.5 x 10(-8) refractive-index units per 0.01 degrees phase change. To our knowledge, this is a significant improvement over previously obtained results when gold was used as the sensor surface. Such an improvement in the sensitivity limit should allow SPR biosensors to become a possible replacement for conventional biosensing techniques based on fluorescence. Monitoring of the bovine serum albumin (BSA) binding reaction with BSA antibodies is also demonstrated.

Antigen-Antibody Complex↗

Analysis of performance optimization in supercontinuum sources.

We have determined the cause of performance variation as a function of system parameters in supercontinuum (SC) sources in a normal-dispersion fiber by numerically analyzing the noise evolution of the SC. High-order nonlinearity was considered in such an analysis for the first time to our knowledge. We found that the evolution of noise along the SC fiber has two stages: First, the noise is governed by dispersion, which is different from that of the signal, whereas self-steeping leads to an asymmetric noise distribution across the spectrum. Second, four-wave mixing generates new noise components, whereas Raman scattering augments the asymmetry. We evaluated the qualities of the spectrally sliced pulses at several stages to verify the analysis and found an asymmetric profile of the sliced-pulses' quality versus frequency.

Journal Article↗