Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging.

RATIONALE AND OBJECTIVES: To improve effective scan time and image quality in cone-beam computed tomography (CT), Parker's weighting function (half scan [HS]-Feldkamp-Davis-Kress [FDK]) extended to a larger range up to 2pi was proposed as new half-scan algorithm (NHS-FDK). We conducted a practical physical evaluation of NHS-FDK and HS-FDK using 256-detector row CT. MATERIALS AND METHODS: Three types of weighting function (full-scan [FS-FDK], HS-FDK, and NHS-FDK) were evaluated by using 256-detector row CT for five variables, ie, point spread function, image noise, CT number uniformity, Feldkamp artifact, temporal resolution, and clinical evaluation. RESULTS: Image noise, Feldkamp artifact, and temporal resolution were dependent on weighting function. Image noise magnitude was independent of projection angle for all regions of interest with FS-FDK, but showed a symmetric pattern with projection angle with HS-FDK and NHS-FDK. With regard to temporal resolution, NHS-FDK did not remove the motion artifact in the heart except in such slower motion organs as the pulmonary vessels, whereas HS-FDK reduced the motion artifact in the heart. HS-FDK had an even more incomplete data region in the Radon space than FS-FDK, suggesting that it would provide poor image quality distant to the midplane in the longitudinal direction. In practical testing in human subjects, HS-FDK showed inferior performance in all variables except temporal resolution. CONCLUSION: Despite its inferiority to FS-FDK for static objects, HS-FDK may be useful in chest imaging. Contrary to previous findings using static images, NHS-FDK failed to show advantages over HS-FDK or FS-FDK in a moving phantom and human subjects.

Adult↗

Accuracy of PET for diagnosis of solid pulmonary lesions with 18F-FDG uptake below the standardized uptake value of 2.5.

UNLABELLED: Benign and malignant pulmonary lesions usually are differentiated by 18F-FDG PET with a semiquantitative 18F-FDG standardized uptake value (SUV) of 2.5. However, the frequency of malignancies with an SUV of <2.5 is significant, and pulmonary nodules with low 18F-FDG uptake often present diagnostic challenges. METHODS: Among 360 consecutive patients who underwent 18F-FDG PET to evaluate pulmonary nodules found on CT, we retrospectively analyzed 43 who had solid pulmonary lesions (excluding lesions with ground-glass opacity, infiltration, or benign calcification) with an SUV of <2.5. The uptake of 18F-FDG was graded by a visual method (absent, faint, moderate, or intense) and 2 semiquantitative methods (SUV and contrast ratio [CR]). Final classification was based on histopathologic findings or at least 6 mo of clinical follow-up. RESULTS: We found 16 malignant (diameter, 8-32 mm) and 27 benign (7-36 mm) lesions. When faint visual uptake was the cutoff for positive 18F-FDG PET results, the receiver-operating-characteristic (ROC) analysis correctly identified all 16 malignancies and yielded false-positive results for 10 of 27 benign lesions. Sensitivity was 100%, specificity was 63%, and the positive and negative predictive values were 62% and 100%, respectively. When an SUV of 1.59 was the cutoff for positive 18F-FDG PET results, the ROC analysis revealed 81% sensitivity, 85% specificity, and positive and negative predictive values of 77% and 89%, respectively. At a cutoff for positive 18F-FDG PET results of a CR of 0.29, the ROC analysis revealed 75% sensitivity, 82% specificity, and positive and negative predictive values of 71% and 85%, respectively. The areas under the curve in ROC analyses did not differ significantly among the 3 analyses (visual, 0.84; SUV, 0.81; and CR, 0.82). Analyses of intra- and interobserver variabilities indicated that visual and SUV analyses were quite reproducible, whereas CR analysis was poorly reproducible. CONCLUSION: These results suggested that for solid pulmonary lesions with low 18F-FDG uptake, semiquantitative approaches do not improve the accuracy of 18F-FDG PET over that obtained with visual analysis. Pulmonary lesions with visually absent uptake indicate that the probability of malignancies is very low. In contrast, the probability of malignancy in any visually evident lesion is about 60%.

Adult↗

Myocardial perfusion imaging in pediatric cardiology.

Myocardial perfusion imaging (MPI) is an important procedure in pediatric cardiology in terms of evaluating myocardial ischemia, infarction and damage associated with various congenital or acquired heart diseases, such as Kawasaki disease, anomalous origin of the left coronary artery from the pulmonary artery and complete transposition of the great arteries after arterial switch surgery. This type of imaging can detect myocardial damage in the morphological right ventricle when it functions as a systemic pumping chamber in patients with complex congenital heart diseases after intra-cardiac repair. Myocardial perfusion imaging can also evaluate myocardial damage associated with primary or secondary cardiomyopathy in children. The magnitude of increased right ventricular uptake on MPI is a useful noninvasive means of estimating right ventricular pressure overload due to congenital heart or pulmonary diseases. This article reviews myocardial perfusion tracers and pharmacological stress tests used to diagnose heart conditions in children, and the current clinical roles of MPI in pediatric cardiology.

Adolescent↗

Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis.

All previous validation studies of quantitative gated single-photon emission tomography (QGS) have examined relatively few patients, and the accuracy of QGS thus remains uncertain. We performed a meta-analysis of data from 301 participants in ten studies that compared QGS using technetium-99m-labelled tracers with contrast left ventriculography (LVG), and from 112 participants in six studies that compared QGS with magnetic resonance imaging (MRI). Linear regression and Bland-Altman analyses were used to evaluate pooled data from individuals across the studies. The correlation between QGS and LVG for end-diastolic volume (EDV) (r=0.81, SEE=27 ml), end-systolic volume (ESV) (r=0.83, SEE=18 ml) and ejection fraction (EF) (r=0.79, SEE=8.3%) was good, as was that between QGS and MRI for EDV (r=0.87, SEE=34 ml), ESV (r=0.89, SEE=27 ml) and EF (r=0.88, SEE=7.2%). However, Bland-Altman plots indicated that LVG minus QGS differences for EDV generated a systematic and random error of 32+/-58 ml (mean+/-2SD), and that MRI minus QGS generated an error of 13+/-73 ml. In the subgroup of patients in whom ECG gating was set at eight intervals, QGS significantly underestimated EF by 7.6%+/-17.4% (mean+/-2SD) compared with LVG and by 6.3%+/-14.6% compared with MRI; no such underestimation was observed in the subgroup in whom ECG gating was set at 16 intervals. We conclude that in patients with ECG gating set at eight intervals, QGS systematically underestimates LV volumes and EF compared with both LVG and MRI. Since QGS also shows considerable variations around the systematic deviations, there remains uncertainty over whether an individual value determined with QGS approximates the true LV volumes and EF.

Aged↗

Growth of stenotic lesions after balloon angioplasty for pulmonary artery stenosis after arterial switch operation.

Little is known about the growth potential of pulmonary stenotic lesions after balloon angioplasty (BA) in patients after the arterial switch operation. The aim of this study was to evaluate the growth potential of pulmonary stenotic lesions after BA and assess the midterm results of BA for pulmonary artery stenosis after the arterial switch operation. Thirty-seven patients who had undergone 52 procedures had repeat catheterization at a median of 43 years (range 1.2 to 9.3 ys) after BA. To adjust growth-related changes in the size of the pulmonary artery, the stenotic diameter was expressed as a percentage of normal (%N). An immediate increase of 63 +/- 45% in the stenotic diameter and a reduction of 51 +/- 33% in the pressure gradient occurred across the stenotic lesions after BA. The right ventricular-aortic systolic pressure ratio decreased from 0.67 +/- 0.24 to 0.51 +/- 0.12 after BA (p <0.0001). Compared with immediate data after BA, there was no significant change in the growth-adjusted diameter of the stenotic lesions (68 +/- 26 %N after BA vs 65 +/- 25 %N at follow-up, p = 0.08), and the pressure gradient (16 +/- 13 mm Hg after BA vs 20 +/- 21 mm Hg at follow-up, p = 0.10). The ventricular-aortic systolic pressure ratio also did not change (0.51 +/- 0.12 after BA vs 0.50 +/- 0.21 at follow-up, p = 0.57). Restenosis occurred in 3 of 26 vessels (12%) after successful BA in which the diameter increased >50% after BA. Our data suggest that pulmonary stenotic lesions after BA develop with age in growing children after the arterial switch operation, and the efficacy of the BA may be long lasting.

Adolescent↗

Scatter correction by two-window method standardizes cardiac I-123 MIBG uptake in various gamma camera systems.

UNLABELLED: Heart to mediastinum count ratio (H/M) has been commonly utilized as an indicator of myocardial I-123 MIBG uptake. However, normal ranges of H/M were markedly different among various gamma camera systems. The purpose of this study was to clarify whether scatter correction by two-window method standardizes H/M among various gamma camera systems. METHODS: Scatter uncorrected and corrected MIBG imaging was acquired in phantom and human studies in combination with low energy high-resolution collimator (LEHR) and medium energy collimator (MEC). For scatter correction, energy window width of 159 keV +/- 10% was applied to main window imaging and 193 keV +/- 9.5% was applied to upper window imaging for scatter correction. RESULTS: In phantom study, a significant difference was observed in uncorrected H/M among three gamma camera systems using LEHR or MEC (2.09 +/- 0.06 vs. 2.58 +/- 0.03 in GCA7200 camera, 2.00 +/- 0.07 vs. 2.42 +/- 0.06 in DS7 camera and 2.16 +/- 0.04 vs. 2.67 +/- 0.07 in Vertex plus camera). However, there was no significant difference in corrected H/M among the three gamma camera systems, either with LEHR or MEC (2.70 +/- 0.07 vs. 2.69 +/- 0.07 in GCA7200 camera, 2.66 +/- 0.08 vs. 2.61 +/- 0.05 in DS7 camera and 2.66 +/- 0.05 vs. 2.61 +/- 0.05 in Vertex plus camera). In human study, uncorrected H/M in DS7 camera with LEHC was significantly lower than that in GCA7200 camera with MEC (1.60 +/- 0.37 vs. 1.85 +/- 0.54, N = 14). In contrast, the difference was insignificant in corrected H/M (2.12 +/- 0.59 vs. 2.16 +/- 0.68). There was a very excellent correlation in corrected H/M between DS7 and GCA7200 cameras (r = 0.991, p < 0.001). CONCLUSION: This study demonstrated that scatter correction by the two-window method standardizes the H/M in MIBG scintigraphy either with LEHR or MEC. Scatter corrected H/M can be applied to measure a standardized parameter of MIBG uptake in human clinical studies using various gamma camera systems.

3-Iodobenzylguanidine↗

Nonobstructive ASD creation to qualify patients for the Fontan operation: effects on pulmonary hypertension due to restrictive left atrioventricular valve and interatrial communication.

Pulmonary hypertension (PH) due to elevated left atrial pressure (LAp) caused by restrictive left atrioventricular valve and interatrial communication sometimes precludes patients with univentricular heart from undergoing the Fontan operation. We have created atrial septal defect (ASD) for such patients to reduce LAp and then pulmonary arterial pressure (PAp) and pulmonary vascular resistance (Rp) in an attempt to qualify the patients for the Fontan repair. This study was performed to clarify the efficacy and limitation of this approach. Twelve patients with PH (mean PAp > 20 mm Hg and/or Rp > 3.0 Wood's unit/m(2)) due to obstruction at the LA exit underwent ASD creation at the age of 4.0 +/- 4.0 (mean +/- SD) years. Follow-up catheterization 14.9 +/- 15.6 months after the ASD creation demonstrated marked reductions in mean LAp (from 21 +/- 5 to 8 +/- 2 mm Hg), mean PAp (from 39 +/- 13 to 17 +/- 4 mm Hg), and Rp (from 6.2 +/- 4.5 to 2.7 +/- 1.4 Wood's unit/m(2)) compared with those before the procedure (all P < 0.0001). Seven of the 12 patients (58%) qualified for the Fontan operation (mean PAp < 20 mm Hg, Rp < 3.0 Wood's unit/m(2), and Nakata's PA index > or = 250) after the ASD creation. Final surgical outcomes of the seven patients included successful Fontan operation in five and biventricular repair in two. Patients with severe PH [mean PAp > or = 45 mm Hg (n = 6) or Rp > or = 4.5 Wood's unit/m(2) (n = 5)] before the ASD creation qualified less frequently for the Fontan repair than those with mild PH [mean PAp < 45 mm Hg (n = 6; 17% vs. 100%; P = 0.008) or Rp < 4.5 Wood's unit/m(2) (n = 7; 20 vs. 86%; P = 0.045)]. Patients with PA banded after 6 months of age (n = 3) qualified less frequently for the Fontan operation than those banded before 6 months of age (n = 6; 0 vs. 83%; P = 0.048). These data suggest that ASD creation is an effective approach to qualify patients for the Fontan operation in the presence of restrictive left atrioventricular valve and interatrial obstruction, except those with longstanding severe PH following delayed PA banding.

Cardiac Catheterization↗

Fasting plasma ghrelin levels are negatively correlated with insulin resistance and PAI-1, but not with leptin, in obese children and adolescents.

Ghrelin is a novel growth hormone-releasing peptide isolated from human and rat stomach that induces weight gain by increasing food intake and reducing fat utilization. Although recent data indicate that ghrelin is downregulated in human adult obesity, the characteristics of human obesity are heterogeneous, especially in children and adolescents, and depend on the distribution of subcutaneous and visceral fat tissue. We measured fasting plasma ghrelin concentrations by radioimmunoassay in 49 obese Japanese children and adolescents (38 boys and 11 girls; mean age 10.2 +/- 2.8 years; BMI 28.0 +/- 4.5 kg/m(2), percent overweight 56.0 +/- 20.7%), and analyzed associations of their ghrelin concentrations with their body composition, insulin resistance, and adipocytokine concentrations. Fasting plasma ghrelin levels were negatively correlated with BMI and waist circumference, but not with percent overweight or percent body fat, whereas fasting leptin levels were positively correlated with all of the following parameters: BMI, waist circumference, percent overweight, and percent body fat. Plasma ghrelin levels were negatively correlated with fasting immunoreactive insulin, homeostasis model assessment insulin resistance index, and quantitative insulin sensitivity check index values. There was no correlation between plasma ghrelin and leptin, but ghrelin was negatively correlated with the PAI-1 concentrations. The results suggest that the downregulation of ghrelin secretion may be a consequence of higher insulin resistance associated with visceral fat accumulation and elevated PAI-1 concentrations, and not a consequence of total body fat accumulation associated with elevated leptin concentrations.

Adolescent↗

Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography): a preliminary study with a porcine model.

This is a preliminary demonstration of volumetric cine imaging of cardiovascular circulation in domestic pigs using a prototype 256-detector row computed tomography (CT) scanner. The scan range is approximately 120 mm in the craniocaudal direction, with a 0.5-mm slice thickness. The thin sections can be used to create cine loops in multiple planes. Thus, the 256-detector row CT scanner overcomes some of the limitations of present helical CT methods.

Animals↗

Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography: initial experience.

OBJECTIVE: The feasibility of human cardiac imaging using a prototype 256-detector row cone-beam computed tomography (256CBCT) scanner without electrocardiographic gating was examined. METHODS: Two healthy male volunteers were examined by contrast-enhanced 256CBCT. The number of detectors was 912 x 256, each measuring approximately 0.5 mm x 0.5 mm at the center of rotation. The craniocaudal coverage was approximately 100 mm after reconstruction by the Feldkamp-Davis-Kress algorithm. The effective time resolution was 500 milliseconds using a half-scan algorithm. RESULTS: Serial enhancement of the left ventricular myocardium was detected. The right and left coronary arteries at proximal and distal segments were depicted without significant blurring. Although the left ventricular wall motion on cine images was not smooth over time, it was possible to measure ventricular volume and ejection fraction. CONCLUSIONS: Using the 256CBCT, it was possible to visualize the coronary arteries, myocardial perfusion, and ventricular contraction simultaneously during a single acquisition.

Algorithms↗