End-organ function during chronic nonpulsatile circulation.

BACKGROUND: Evolving blood pump technology has produced user-friendly continuous flow left ventricular assist devices, but uncertainty exists about the safety of chronic nonpulsatile circulation. We established consistently nonpulsatile blood flow in a sheep model using the Terumo magnetically suspended centrifugal pump. We then compared end-organ function between pulseless and control animals. METHODS: Fifteen healthy sheep (65 to 85 kg) were allocated to either left ventricular assist device (n = 9) or control (n = 6) groups. We implanted the device through a left thoracotomy and determined the flow rate at which pulse pressure was absent. The flow rate was then adjusted to exceed that rate (4.2 +/- 1.5 L/min), and all variables of pump function were continuously monitored by computer. Blood tests were taken serially for hepatic and renal function and plasma renin levels. The sheep were sacrificed electively at 30 (n = 3), 90 (n = 4), 180 (n = 1), and 340 (n = 1) days. Detailed histologic examination was made of the brain, liver, kidney, myocardium, and major arteries. RESULTS: All animals remained in good condition until sacrifice. All measures of end-organ function remained within normal limits for both groups. There were no histologic differences between the organs of pulsatile and nonpulsatile animals. Although there was no significant difference in mean blood pressure, plasma renin levels were substantially elevated in pulseless animals (1.4 +/- 0.3 pg/mL versus 2.9 +/- 0.3 pg/mL; p < 0.05). We also identified thinning of the medial layer of the ascending aorta in nonpulsatile sheep (1.8 +/- 0.4 mm in left ventricular assist device animals versus 2.6 +/- 0.6 mm in control sheep; p < 0.05). CONCLUSIONS: Chronic nonpulsatile circulation was well tolerated, and we found neither functional nor histologic changes in major end organs. The renin-angiotensin system was upregulated, but this did not provide a significant rise in blood pressure. The changes in the aortic wall merit further investigation. As a result of these findings, we consider that nonpulsatile devices can be used safely for long-term circulatory support.

Animals↗

[Left ventricular assist system with a magnetically levitated impeller technology].

After the accumulation of clinical experience with the current generation of pulsatile implantable left ventricular assist systems (LVAS), these devices have demonstrated major limitations: high incidence of thromboembolic complications; large size; high infection rate; and limited long-term durability. To address the limitations of current-generation LVAS, second- and third-generation LVAS utilizing rotary blood pump technology are currently undergoing clinical trials and the final stage of product development. Among them, the rotary blood pump with a magnetically levitated impeller is one of the most promising pumps for long-term circulatory assist. The Terumo DuraHeart LVAS is one of the third-generation LVAS using a centrifugal pump with a magnetically levitated impeller. This article describes the characteristics of the DuraHeart LVAS and its development status.

Heart Failure↗