Multi-channel linear descriptors for event-related EEG collected in brain computer interface.

By three multi-channel linear descriptors, i.e. spatial complexity (omega), field power (sigma) and frequency of field changes (phi), event-related EEG data within 8-30 Hz were investigated during imagination of left or right hand movement. Studies on the event-related EEG data indicate that a two-channel version of omega, sigma and phi could reflect the antagonistic ERD/ERS patterns over contralateral and ipsilateral areas and also characterize different phases of the changing brain states in the event-related paradigm. Based on the selective two-channel linear descriptors, the left and right hand motor imagery tasks are classified to obtain satisfactory results, which testify the validity of the three linear descriptors omega, sigma and phi for characterizing event-related EEG. The preliminary results show that omega, sigma together with phi have good separability for left and right hand motor imagery tasks, which could be considered for classification of two classes of EEG patterns in the application of brain computer interfaces.

Algorithms↗

Effects and wavelet spectral entropy analysis of rhubarb extracts rhein on synaptic transmission in rat hippocampal ca1 area in vitro.

BACKGROUND: 5-dihydroxyanthraquinone-2-carboxylic acid (rhein) inhibits oxidoreduction induced by reducing nicotingamide adenine dinucleotide in the mitochondria and reducing reactive oxygen species, it also suppresses lipid peroxidation in rat brain homogenates. This study was to assess the effects of anthraquinone derivatives, rhein on synaptic transmission in the rat hippocampal CA1 pyramidal cell layer by intracellular recording. METHODS: The excitatory postsynaptic potential (EPSP) evoked by stimulation of the Schaffer collaterals in the presence of bicuculline (15 micromol/L) was depressed by application of rhein (0.3 - 30 micromol/L). The amplitude of the EPSP was restored within 20 minutes after removal of rhein from the supernatant. At a concentration of 30 micromol/L, rhein reduced the amplitude of the EPSP to 42% +/- 3.7% (n = 24) of the control. Subsequently, wavelet spectral entropy was used to analyze the EPSP. RESULTS: A strong positive correlation was observed between the wavelet spectral entropy and other parameters such as amplitude, slope of rising phase and slope of descending phase of the EPSP. The paired-pulse facilitation (PPF) of the EPSP was significantly increased by rhein (30 micromol/L). The inhibitory postsynaptic potential (IPSP) recorded in the presence of CNQX (20 micromol/L) and APV (40 micromol/L) is not altered by rhein (30 micromol/L). CONCLUSIONS: Rhein (30 micromol/L) can decrease the frequency but not the amplitude of the miniature EPSP (mEPSP). It is suggested that rhein inhibits excitatory synaptic transmission by decreasing the release of glutamate in rat hippocampal CA1 pyramidal neurons.

Animals↗

Discussion on "Towards a quantitative characterization of functional states of the brain: from the non-linear methodology to the global linear description" by J. Wackermann.

Wackermann (1999) [Wackermann, J., 1999. Towards a quantitative characterization of functional states of the brain: from the non-linear methodology to the global linear description. Int. J. Psychophysiol. 34, 65-80] proposed Sigma-phi-Omega system for describing the global brain macro-state, in which Omega complexity was used to quantify the degree of synchrony between spatially distributed EEG processes. In this paper the effect of signal power on Omega complexity is discussed, which was not considered in Wackermann's paper (1999). Then an improved method for eliminating the effect of signal power on Omega complexity is proposed. Finally a case study on the degree of synchrony between two-channel EEG signals over different brain regions during hand motor imagery is given. The results show that the improved Omega complexity measure would characterize the true degree of synchrony among the EEG signals by eliminating the influence of signal power.

Algorithms↗

Study on a non-contact life parameter detection system using millimeter wave.

OBJECTIVE: To study the basic principle and design method of a non-contact life detection system using 36 GHz millimeter wave. METHOD: Continuous wave radar techniques and signal processing techniques including zero intermediate frequency, frequency domain accumulation and adaptive noise cancellation were used in the system. RESULT: When the radiated power was about a milliwatt (mW) and detection range was up to 3 meters, the experimental results showed that this system can well detect the heartbeat and respiration signals from human subjects through common clothes and quilts. CONCLUSION: The system is feasible and effective due to its high detection sensitivity, small antenna, simple structure, easy miniaturization and safety to the human subject. It can be used for long-term continuous monitoring, especially suitable for the astronauts.

Aerospace Medicine↗

[The developments of medical monitoring techniques].

Based on analyzing the problems of the existing medical monitoring systems and the clinical needs in medicine the main development aspects of modern medical monitoring techniques are discussed in the paper. Then the urgent needs of monitoring techniques are presented here.

Biosensing Techniques↗