PubMed Health⌕ Search

Biomedical subjects

Chris Pohl

Publications and source records attributed to Chris Pohl.

3 recordsLinked to original sources

Oligosaccharide analysis by capillary-scale high-pH anion-exchange chromatography with on-line ion-trap mass spectrometry.

A capillary-scale high-pH anion-exchange chromatography (HPAEC) system for the analysis of carbohydrates was developed, in combination with two parallel on-line detection methods of sub-picomolar sensitivity: (1) pulsed amperometric detection (PAD); (2) capillary-scale desalting followed by electrospray ion-trap (IT) mass spectrometry (MS). The capillary chromatographic system combined the superb selectivity of HPAEC that allows routine separation of isomeric oligosaccharides with the information on monosaccharide sequence and linkage positions obtained by MS/MS fragmentation using the IT-MS. The applicability of the system in biomedical research was demonstrated by its use for the analysis of a urine sample of a GM1-gangliosidosis patient. Isomeric glycans in the sample could be resolved by HPAEC and assigned on the basis of the monosaccharide linkage information revealed by on-line IT-MS/MS.

Chromatography, Ion Exchange↗

Recent developments in electrolytic devices for ion chromatography.

Recent developments in new electrolytic devices that utilize the electrolysis of water and charge-selective electromigration of ions through ion-exchange media have significantly changed the routine operation of ion chromatographic methods. Examples of these new electrolytic devices include on-line eluent generators that produce high-purity electrolyte eluents using deionized water as the carrier stream, continuously regenerated trap columns that remove ionic contaminants in the eluents, and continuously regenerated suppressors that reduce eluent background conductance prior to conductivity detection. The combined use of these electrolytic devices has made it possible to perform various ion chromatographic separations using only deionized water as the mobile phase. This paper reviews the operation principles of these electrolytic devices and their applications in the ion chromatographic determination of anionic and cationic analytes.

Cation Exchange Resins↗

Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.

An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line electrolytic eluent generator and detected using the suppressed conductivity detection method. The method performance was evaluated by analyzing synthetic water samples containing additives encountered in the power plant water samples and four water samples from a fossil fuel power plant. The relative standard deviations of retention times of analyte ions separated on the hydroxide-selective anion-exchange column were less than 0.4%. The recoveries of analyte ions spiked into the synthetic water samples at concentrations of 0.13-1.0 microg/l were in the range of 70-120%. The method detection limits for analyte ions in deionized water were 0.0099, 0.0056, 0.019, 0.057, 0.0084, 0.023, 0.067, 0.037, and 0.079 microg/l for fluoride, acetate, formate, chloride, nitrite, sulfate, bromide, nitrate, and phosphate, respectively.