Diaphragmatic function in advanced Duchenne muscular dystrophy.

The aim of this study was to assess diaphragm electrical activation and diaphragm strength in patients with advanced Duchenne muscular dystrophy during resting conditions. Eight patients with advanced Duchenne muscular dystrophy (age of 25 +/- 2 years) were studied during tidal breathing, maximal inspiratory capacity, maximal sniff inhalations, and magnetic stimulation of the phrenic nerves. Six patients were prescribed home mechanical ventilation (five non-invasive and one tracheotomy). Transdiaphragmatic pressure and diaphragm electrical activation were measured using an esophageal catheter. During tidal breathing (tidal volume 198 +/- 83 ml, breathing frequency 25 +/- 7), inspiratory diaphragm electrical activation was clearly detectable in seven out of eight patients and was 12 +/- 7 times above the noise level, and represented 45 +/- 19% of the maximum diaphragm electrical activation. Mean inspiratory transdiaphragmatic pressure during tidal breathing was 1.5 +/- 1.2 cmH2O, and during maximal sniff was 7.6 +/- 3.6 cmH2O. Twitch transdiaphragmatic pressure deflections could not be detected. This study shows that despite near complete loss of diaphragm strength in advanced Duchenne muscular dystrophy, diaphragm electrical activation measured with an esophageal electrode array remains clearly detectable in all but one patient.

Action Potentials↗

Diaphragm electrical activity during expiration in mechanically ventilated infants.

The presence of diaphragm electrical activity (EAdi) during expiration is believed to be involved in the maintenance of end-expiratory lung volume (EELV) and has never been studied in intubated and mechanically ventilated infants. The aim of this study was to quantify the amplitude of diaphragm electrical activity present during expiration in mechanically ventilated infants and to measure the impact of removing positive end-expiratory pressure (PEEP) on this activity. We studied the EAdi in 16 ready-to-be weaned intubated infants who were breathing on their prescribed ventilator and PEEP settings. In all 16 patients, 5 min of data were collected on the prescribed ventilator settings. In a subset of eight patients, the PEEP was briefly reduced to zero PEEP (ZEEP). EAdi was recorded with miniaturized sensors placed on a conventional nasogastric feeding tube. Airway pressure (Paw) was also measured. For each spontaneous breath, we identified the neural inspiration and neural expiration. Neural expiration was divided into quartiles (Q1, Q2, Q3, and Q4), and the amplitude of EAdi calculated for each Q1-Q4 represented 95 +/- 29%, 31 +/- 15%, 15 +/- 8%, and 12 +/- 7%, respectively, of the inspiratory EAdi amplitude. EAdi for Q3-Q4 significantly increased during ZEEP, and decreased after reapplication of PEEP. These findings confirm that the diaphragm remains partially active during expiration in intubated and mechanically ventilated infants and that removal of PEEP affects this tonic activity. This could have potential implications on the management of PEEP in intubated infants.

Diaphragm↗

Closed-loop control of respiratory drive using pressure-support ventilation: target drive ventilation.

By using diaphragm electrical activity (multiple-array esophageal electrode) as an index of respiratory drive, and allowing such activity above or below a preset target range to indicate an increased or reduced demand for ventilatory assistance (target drive ventilation), we evaluated whether the level of pressure-support ventilation can be automatically adjusted in response to exercise-induced changes in ventilatory demand. Eleven healthy individuals breathed through a circuit (18 cm H2O/L/second inspiratory resistance at 1 L/second flow; 0.5-1.0 L/second expiratory flow limitation) connected to a modified ventilator. Subjects breathed for 6-minute periods at rest and during 20 and 40 W of bicycle exercise, with and without target drive ventilation (the target was set to 60% of the increase in diaphragm electrical activity observed between rest and 20 W of unassisted exercise). With target drive ventilation during exercise, the level of pressure-support ventilation was automatically increased, reaching 13.3 +/- 4.0 and 20.3 +/- 2.8 cm H2O during 20- and 40-W exercise, respectively, whereas diaphragm electrical activity was reduced to a level within the target range. Both diaphragmatic pressure-time product and end-tidal CO2 were significantly reduced with target drive ventilation at the end of the 20- (p < 0.01) and 40-W (p < 0.001) exercise periods. Minute ventilation was not altered. These results demonstrate that target drive ventilation can automatically adjust pressure-support ventilation, maintaining a constant neural drive and compensating for changes in respiratory demand.

Adult↗

Effect of increased diaphragm activation on diaphragm power spectrum center frequency.

Increased transdiaphragmatic pressure, reduced muscle blood flow, and increased duty cycle have all been associated with a reduction in the center frequency (CFdi) of the diaphragm's electrical activity (EAdi). However, the specific influence of diaphragm activation on CFdi is unknown. We evaluated whether increased diaphragm activation would result in a greater decline in the CFdi when pressure-time product (PTPdi) was kept constant. Five healthy subjects performed periods of intermittent quasi-static diaphragmatic contractions with a fixed duty cycle. In separate runs, subjects targeted transdiaphragmatic pressures (Pdi) by performing end-inspiratory holds with the glottis open and expulsive maneuvers at end-expiratory lung volume (EELV). Diaphragm activation and pressures were measured with an electrode array and balloons mounted on an esophago-gastric catheter, respectively. The EAdi, which was 25+/-8%(S.D.) of maximum at EELV, increased to 61+/-8% (P<0.001) when an identical Pdi (averaging 31+/-13 cmH2O) was generated at a higher lung volume (77% of inspiratory capacity). The latter was associated with a 17% greater decline in CFdi (P=0.012). In order to reproduce at EELV, the decrease in CFdi observed at the increased lung volume, a two-fold increase in PTPdi was required. We conclude that CFdi responds specifically to increased diaphragm activation when pressure-time product remains constant.

Action Potentials↗

Prolonged neural expiratory time induced by mechanical ventilation in infants.

Mechanical ventilation may interfere with the spontaneous breathing pattern in infants because they have strong reflexes that play a large role in the control of breathing. This study aimed to answer the following questions: does a ventilator-assisted breath 1) reduce neural inspiratory time, 2) reduce the amplitude of the diaphragm electrical activity, and 3) prolong neural expiration, within the delivered breath? In 14 infants recovering from acute respiratory failure (mean age and weight were 2.3 +/- 1.3 mo and 3.95 +/- 0.82 kg, respectively), we measured 1) the electrical activity of the diaphragm with a multiple-array esophageal electrode, and 2) airway opening pressure, while patients breathed on synchronized intermittent mandatory ventilation (mean rate, 11.2 +/- 6.5 breaths/min). We compared neural inspiratory and expiratory times for the mandatory breaths and for the spontaneous breaths immediately preceding and following the mandatory breath. Although neural inspiratory time was not different between mandatory and spontaneous breaths, neural expiratory time was significantly increased (p < 0.001) for the mandatory breaths (953 +/- 449 ms) compared with the premandatory and postmandatory spontaneous breaths (607 +/- 268 ms and 560 +/- 227 ms, respectively). Delivery of the mandatory breath resulted in a reduction in neural respiratory frequency by 28.6 +/- 6.4% from the spontaneous premandatory frequency. The magnitude of inspiratory electrical activity of the diaphragm was similar for all three breath conditions. For the mandatory breaths, ventilatory assist persisted for 507 +/- 169 ms after the end of neural inspiratory time. Infant-ventilator asynchrony (both inspiratory and expiratory asynchrony) was present in every mandatory breath and constituted 53.4 +/- 26.2% of the total breath duration.