PubMed Health⌕ Search

Biomedical subjects

Christian Berger-Vachon

Publications and source records attributed to Christian Berger-Vachon.

4 recordsLinked to original sources

Automatic analysis of auditory nerve electrically evoked compound action potential with an artificial neural network.

The auditory nerve's electrically evoked compound action potential is recorded in deaf patients equipped with the Nucleus 24 cochlear implant using a reverse telemetry system (NRT). Since the threshold of the NRT response (NRT-T) is thought to reflect the psychophysics needed for programming cochlear implants, efforts have been made by specialized management teams to develop its use. This study aimed at developing a valid tool, based on artificial neural networks (ANN) technology, for automatic estimation of NRT-T. The ANN used was a single layer perceptron, trained with 120 NRT traces. Learning traces differed from data used for the validation. A total of 550 NRT traces from 11 cochlear implant subjects were analyzed separately by the system and by a group of physicians with expertise in NRT analysis. Both worked to determine 37 NRT-T values, using the response amplitude growth function (AGF) (linear regression of response amplitudes obtained at decreasing stimulus intensity levels). The validity of the system was assessed by comparing the NRT-T values automatically determined by the system with those determined by the physicians. A strong correlation was found between automatic and physician-obtained NRT-T values (Pearson r correlation coefficient >0.9). ANOVA statistics confirmed that automatic NRT-Ts did not differ from physician-obtained values (F = 0.08999, P = 0.03). Moreover, the average error between NRT-Ts predicted by the system and NRT-Ts measured by the physicians (3.6 stimulation units) did not differ significantly from the average error between NRT-Ts measured by each of the three physicians (4.2 stimulation units). In conclusion, the automatic system developed in this study was found to be as efficient as human experts for fitting the amplitude growth function and estimating NRT-T, with the advantage of considerable time-saving.

Cochlear Implants↗

Influence of stimulus frequency on NRT recordings.

Research in neural response telemetry (NRT) with the Cochlear 'Nucleus' CI24M Implant began a few years ago, using the first NRT software version (2.04). It has been demonstrated that NRT offers possibilities for fitting the implant speech processor. NRT sessions, however, remain lengthy for the patients, especially for children, and NRT research is seeking to reduce session time. The new version of the NRT software (3.0) allows implant stimulation up to 400 Hz, whereas the previous version stimulated only up to 80 Hz. The time gained is very significant. The goal of the present study was to observe and assess the modifications in NRT produced by these higher stimulus frequencies. Growth functions were measured in six adult patients for electrodes 5-10-15-20 at frequencies of 20, 80, 150, 250 and 365 Hz to determine NRT thresholds (NRT-T). Subjective detection thresholds (T) were also measured for the same electrodes and frequencies. The results showed that the number of valid responses, like the quality and amplitude of the NRT response, quickly decreased at these higher rates. Consequently, the number of measurement points used for the growth function decreased with frequency. Moreover, when frequency increased, the T value decreased while NRT-T increased: the gap between the two thresholds increased with frequency in a linear manner common to all patients. The growth function slopes did not change significantly with frequency.

Auditory Perception↗

Auditory steady-state response evaluation of auditory thresholds in cochlear implant patients.

The aims of this work were to characterize the electrophysiologic response obtained by measurement of the auditory steady-state response (ASSR) in patients with a cochlear implant (MXM Digisonic) and to study the relationship between the subjective thresholds of the implantees and those estimated using electrical auditory steady-state response (ASSR)-based objective audiometry. Five subjects were examined with the use of four carrier frequencies--600, 1000, 2000 and 3500 Hz--modulated at frequencies between 70 and 85Hz, a particular frequency of modulation being represented at a specific electrode (for each carrier frequency) as a particular pulse-width modulation frequency. The protocol consisted of testing output and thresholds for different overall pulse durations for several stimulus (pulse) intensities, rendering multiple threshold measures (in duration) for each subject tested. The non-linearity of response growth, as a function of duration, provided the basis for teasing apart physiologic response and electrical artefact in the suprathreshold recorded responses. Thresholds estimated with use of the electrical ASSR demonstrated reasonably good agreement with the subjective thresholds. The results obtained thus demonstrated the efficacy of the approach and are encouraging for further advances in cochlear implant applications.

Acoustic Stimulation↗

Assessing auditory nerve recovery function with a modified subtraction method: results and mathematical modeling.

OBJECTIVE: One of the main difficulties in electrical compound action potential (ECAP) recordings is to reduce the stimulus artifact due to electrical stimulation. The neural response telemetry (NRT) system of the Nucleus 24 cochlear implant extracts the ECAP response using a forward-masking (standard) subtraction technique. However, it has been shown that this subtraction technique may distort the ECAP responses in certain situations. In order to improve ECAP recordings, a modified forward-masking subtraction technique was recently proposed (Ear Hear. 21 (2000) 280). This modified subtraction technique can be applied to recovery function measurement. The objective of this study is to compare results obtained with the modified method to those obtained using the standard method. METHODS: ECAP responses were recorded in 4 adult patients using a Nucleus 24 cochlear implant. Data were collected for the 20 active electrodes. For each electrode, measurements consisted of the recovery function recording using 16 different Masker-Probe intervals. The modified method was then applied and the results compared with the standard method. RESULTS: Comparison between the two methods revealed that results were different when using the standard or modified method. Using the modified method, more ECAP responses were obtained (61.8 vs. 44.2%), but the P1 peak was sometimes attenuated; when using the standard method, N1 peak was missing in many cases. A mathematical model has been established and the mathematical simulation confirms the results obtained in patients. CONCLUSIONS: The results suggest that both methods have limitations and advantages. The modified subtraction method seems to be better for analyzing ECAP recordings in recovery function measurement because of the higher number of responses obtained compared to the standard method.

Adult↗