PubMed Health⌕ Search

Biomedical subjects

Christian De Chillou

Publications and source records attributed to Christian De Chillou.

4 recordsLinked to original sources

Simple and efficient identification of conduction gaps in post-ablation recurring atrial flutters.

AIMS: Cavo-tricuspid isthmus (CTI) radiofrequency (RF) ablation is a curative therapy for common atrial flutter (AFl), but is associated with a recurrence rate of 5-26%. Although complete bidirectional conduction block is usually achieved, the recurrence of AF is due to recovered conducting isthmus tissue through which activation wavefronts pass. We evaluated a simple and efficient electrophysiological strategy, which pinpoints the ablation target. METHODS AND RESULTS: Twenty-five patients (19 men), mean age 61 +/- 6, with recurrent AFl required a repeat ablation, 250 +/- 160 days after a successful RF CTI procedure. Transverse CTI conduction was monitored during AFl or coronary sinus (CS) pacing by a 24-pole mapping catheter positioned in the right atrium (RA), with the distal poles in the CS, proximal poles on the lateral RA, and intermediate poles on the CTI. A slow conduction area traversing the CTI (velocity, 37 +/- 22 vs. 98 +/- 26 cm/s on either side, P < 0.05) and a lower potential amplitude than at both sides (0.2 +/- 0.15 vs. 0.5 +/- 0.5 mV, P < 0.05), defined by a bayonet-shaped depolarization sequence, were considered to represent the incomplete line of block (InLOB). An ablation catheter was progressively dragged up to this InLOB, from the tricuspid annulus to the inferior vena cava, analysing the widely separated double potentials (DPs) until these coalesced. In nine patients (35%), the target conduction gap was a coalesced fractionated atrial potential within the InLOB (duration, 77 +/- 12 ms), and in 16 patients (65%), a narrow DP toward the healthy margins of this InLOB (duration, 28 +/- 15 ms). Adopting this strategy yields 100% successful re-ablation of recurring AFl leading to bidirectional block, with a mean 2.7 +/- 1.4 RF applications. CONCLUSION: Transverse CTI mapping precisely locates the InLOB and helps find conduction gaps along the CTI in re-ablation procedures for common AFl.

Atrial Flutter↗

Mechanisms of right atrial tachycardia occurring late after surgical closure of atrial septal defects.

UNLABELLED: Postatriotomy atrial tachycardia ablation. INTRODUCTION: In patients without structural heart disease, the most frequently occurring AT is the common atrial flutter. In patients with repaired congenital heart disease other mechanisms of AT may occur, due to the presence of an atriotomy that can provide a substrate for reentry. The aim of the present study was to identify the mechanisms of atrial tachycardia (AT) occurring late after atrial septum defect (ASD) repair, with the help of a three-dimensional electroanatomical mapping system. METHODS AND RESULTS: Twenty-two consecutive patients presenting with AT underwent complete electroanatomic mapping (CARTO, Biosense Webster, Diamond Bar, CA) of spontaneously occurring and inducible right ATs. Complete maps of 26 ATs were obtained. Three tachycardia mechanisms were identified: single-loop macroreentrant atrial tachycardia (MAT) (n=7), double-loop MAT (n=18), and focal AT (n=1). In all MATs, protected isthmuses were identified as the electrophysiological substrate of the arrhythmia, most frequently the cavotricuspid isthmus (CTI) (n=24), and a gap between the inferior vena cava and a line of double potentials (n=11). A mean number of 13.5+/-2.1 radiofrequency applications were delivered to transect these critical parts of the circuit. During a follow-up of 25+/-16 months the RF ablation was acutely successful in all patients. Thirteen patients (59%) had an early recurrence of MAT and needed an additional ablation procedure. One of those patients needed two additional ablation procedures. CONCLUSIONS: Three-dimensional electroanatomic mapping is useful to identify postsurgical AT mechanisms; the CTI isthmus is involved in 92% MAT, and if the right atrial free wall (RAFW) abnormal tissue related to surgical scar is present this substrate contributes to the MAT circuit.

Adult↗

Catheter ablation or modulation of the AV node.

The ablate and pace strategy may be considered a viable therapy in the palliative management of patients with medically refractory highly symptomatic atrial fibrillation (AF). The overall success rate is approaching 100%, the inhospital course is usually event free, and the procedure is a relatively safe therapeutic option. There is no doubt that one of the major findings after atrioventricular (AV) node ablation is the significant reduction of cardiac symptoms and health care use, while exercise tolerance and quality of life significantly improved after the procedure. It is also well accepted that catheter ablation and pacemaker (PM) implantation are usually associated with significant improvement in left ventricular ejection fraction, particularly in patient with AF and reduced systolic function at baseline. On the other hand, AV node ablation seems unlikely to have a negative effect on long term survival. The mortality rate in some reports have raised concerns about excess deaths (mainly sudden deaths) attributable to AV node ablation and pacing therapy. These findings are not confirmed by recent data. Modulation of the AV node has been more recently introduced in the clinical practice in order to avoid permanent complete AV block and lifetime PM dependency. AV node modulation procedure is effective in approximately 70% of cases. The short duration of following periods does not allow to draw definitive conclusions concerning the potential evolution of AV node conduction disorders. Both AV node ablation and AV node modulation, when successful, are effective means to improve quality of life and cardiac performance in patients with medically refractory AF. The exact place of these procedures is, today, a matter of debate which is more controversial in patients with paroxysmal AF than with uncontrolled permanent AF.

Anticoagulants↗