Christian Fink

Publications and source records attributed to Christian Fink.

At least 55 records · Page 3Linked to original sources

MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils.

PURPOSE: To implement and optimize a real-time pulse sequence and user interface to perform intravascular interventions using active catheter tracking. MATERIALS AND METHODS: In magnetic resonance (MR)-guided interventions, small radio-frequency coils can be used to rapidly determine the device position (active tracking). In this work, active catheter tracking was combined with a dedicated real-time pulse sequence and user interface. The pulse sequence offered the imaging contrasts fast low angle shot (FLASH), true Fast imaging with steady state precession (TrueFISP), and projection MR digital subtraction angiography (MR-DSA), which could be selected by the radiologist from within the scanner room at any time during the intervention. Automatic slice positioning was added to the real-time pulse sequence so that the location of the tracking coils defined the image slice position and orientation. The technique was assessed in phantoms and animal experiments. RESULTS: At a reaction time of 24 msec and a frame rate of three images per second, the movement of an active intravascular catheter could be monitored in the aorta and the renal arteries of a pig. With interactive contrast and orientation changes, the renal vasculature could be assessed by a fully MR-guided catheterization in less than 10 minutes. CONCLUSION: With carefully designed active catheters, a dedicated user interface, and an optimized pulse sequence intravascular interventions can successfully be performed by a single operator from within the MR scanner room.

Animals↗

MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long twisted-pair RF coil was added to a 5 French intravascular catheter with a single tip-tracking coil. With the use of small nonmagnetic electronic components at the catheter tip, and a special switching circuitry outside the catheter, the coil assembly could be operated in two different modes. During MRI, the tip-tracking coil was detuned so that the MR signal was received by the visualization coil only. During tracking, detuning was switched off and the MR signal was predominantly received by the more sensitive tracking coil. The catheter was used in combination with a MR pulse sequence with automatic slice positioning so that the current imaging slice was always placed at the position of the catheter tip. Phantom and animal experiments showed that the catheter tip is better visualized with the combined approach than with a tracking coil alone.

Animals↗

Semiquantitative fast flow velocity measurements using catheter coils with a limited sensitivity profile.

Flow measurements can be used to quantify blood flow during MR-guided intravascular interventional procedures. In this study, a fast flow measurement technique is proposed that quantifies flow velocities in the vicinity of a small RF coil attached to an intravascular catheter. Since the small RF coil receives signal from only a limited volume around the catheter, a spatially nonselective signal reception is employed. To enhance signal from flowing blood, and suppress unwanted signal contributions from static material, a slice-selective RF excitation is used. At a velocity sensitivity of 150 cm/s, a temporal resolution of 2 x TR = 10.2 ms can be achieved. The flow measurement is combined with an automatic slice positioning to facilitate measurements during interventional procedures. The influence of the catheter position in the blood vessel on the velocity measurement was analyzed in simulations. For blood vessels with laminar flow, the simulation showed a systematic deviation between catheter measurement and true flow between -15% and 80%. In four animal experiments, the catheter velocity measurement was compared with results from a conventional ECG-triggered 2D phase-contrast (PC) technique. The shapes of the velocity time curves in the abdominal aorta were nearly identical to the conventional measurements. A relative scaling factor of 0.69-1.19 was found between the catheter velocity measurement and the reference measurement, which could be partly explained by the simulation results.

Animals↗

Measurement of tumor diameter-dependent mobility of lung tumors by dynamic MRI.

BACKGROUND AND PURPOSE: To assess the influence of tumor diameter on tumor mobility and motion of the tumor bearing hemithorax during the whole breathing cycle in patients with stage I non-small-cell lung cancer (NSCLC) using dynamic MRI. PATIENTS AND METHODS: Breathing cycles of thirty-nine patients with solitary NSCLCs were examined using a trueFISP sequence (three images per second). Patients were divided into three groups according to the maximal tumor diameter in the transverse plane (<3, 3-5 and >5 cm). Continuous time-distance curves and deep inspiratory and expiratory positions of the chest wall, the diaphragm and the tumor were measured in three planes. Motion of tumor-bearing and corresponding contralateral non-tumor bearing regions was compared. RESULTS: Patients with a tumor >3 cm showed a significantly lower diaphragmatic motion of the tumor bearing compared with the non-tumor bearing hemithorax in the craniocaudal (CC) directions (tumors 3-5 cm: 23.4+/-1.2 vs 21.1+/-1.5 cm (P<0.05); tumors >5 cm: 23.4+/-1.2 vs 20.1+/-1.6 cm (P<0.01). Tumors >5 cm in the lower lung region showed a significantly lower mobility compared with tumors <3 cm (1.8+/-1.0 vs 3.8+/-0.7 cm, P<0.01) in the CC directions. CONCLUSIONS: Dynamic MRI is a simple non-invasive method to differentiate mobility of tumors with different diameters and its influence on the surrounding tissue. Tumor diameter has a significant influence on tumor mobility and this might be taken into account in future radiotherapy planning.

Adult↗

Determination of modulation of ligand properties of synthetic complex-type biantennary N-glycans by introduction of bisecting GlcNAc in silico, in vitro and in vivo.

We have investigated the consequences of introducing a bisecting GlcNAc moiety into biantennary N-glycans. Computational analysis of glycan conformation with prolonged simulation periods in vacuo and in a solvent box revealed two main effects: backfolding of the alpha1-6 arm and stacking of the bisecting GlcNAc and the neighboring Man/GlcNAc residues of both antennae. Chemoenzymatic synthesis produced the bisecting biantennary decasaccharide N-glycan and its alpha2-3(6)-sialylated variants. They were conjugated to BSA to probe the ligand properties of N-glycans with bisecting GlcNAc. To assess affinity alterations in glycan binding to receptors, testing was performed with purified lectins, cultured cells, tissue sections and animals. The panel of lectins, including an adhesion/growth-regulatory galectin, revealed up to a sixfold difference in affinity constants for these neoglycoproteins relative to data on the unsubstituted glycans reported previously [André, S., Unverzagt, C., Kojima, S., Dong, X., Fink, C., Kayser, K. & Gabius, H.-J. (1997) Bioconjugate Chem. 8, 845-855]. The enhanced affinity for galectin-1 is in accord with the increased percentage of cell positivity in cytofluorimetric and histochemical analysis of carbohydrate-dependent binding of labeled neoglycoproteins to cultured tumor cells and routinely processed lung cancer sections. Intravenous injection of iodinated neoglycoproteins carrying galactose-terminated N-glycans into mice revealed the highest uptake in liver and spleen for the bisecting compound compared with the unsubstituted or core-fucosylated N-glycans. Thus, this substitution modulates ligand properties in interactions with lectins, a key finding of this report. Synthetic glycan tailoring provides a versatile approach to the preparation of newly substituted glycans with favorable ligand properties for medical applications.

Acetylglucosamine↗

Dynamic magnetic resonance tomography and proton magnetic resonance spectroscopy of prostate cancers in rats treated by radiotherapy.

RATIONALE AND OBJECTIVES: To establish an experimental setting for monitoring perfusion and metabolism in orthotopic prostate cancer at 1.5 T using dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) and 1H-MR spectroscopy (MRS). METHODS: Dunning rat prostate cancer cells were injected into the prostate by open surgery. Twelve tumor-bearing rats (5 of these irradiated) and 6 healthy controls were followed up using gadolinium-diethylenetriaminepentaacetic acid -enhanced dynamic MRI and 1H-MRS. Amplitude and the exchange rate constant kep were calculated (2-compartment model). From 1H-MR spectra, ratios of choline (Cho) and creatine (tCr) were calculated. All tumors were examined histologically. RESULTS: On DCE MRI parameter maps, tumors showed increased vascularization. kep and microvessel density were correlated (r = 0.97). Tumors showed elevated Cho/tCr and an unexpected lipid fraction (2.0-2.2 parts per million). Irradiation slowed tumor growth significantly. Changes of perfusion and metabolism could be detected in all tumors during follow up. CONCLUSION: DCE MRI and 1H-MRS has potential to characterize orthotopic Dunning prostate cancer in rats, which is a promising model similar to human prostate carcinomas.

Animals↗

Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels.

RATIONALE AND OBJECTIVES: To compare 1.0 M gadobutrol and 0.5 M Gd-DTPA for contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging (3D MRI). MATERIALS AND METHODS: Ten healthy volunteers (3 females; 7 males; median age, 27 years; age range, 18-31 years) were examined with contrast-enhanced dynamic 3D MRI with parallel acquisition technique (FLASH 3D; reconstruction algorithm: generalized autocalibrating partially parallel acquisitions; acceleration factor: 2; TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; FOV: 500 x 375 mm; matrix: 256 x 86; slab thickness: 180 mm; 36 partitions; voxel size: 4.4 x 2 x 5 mm; TA: 1.48 seconds). Twenty-five consecutive data sets were acquired after intravenous injection of 0.025, 0.05, and 0.1 mmol/kg body weight of gadobutrol and Gd-DTPA. Quantitative measurements of peak signal-to-noise ratios (SNR) of both lungs were performed independently by 3 readers. Bolus transit times through the lungs were assessed from signal intensity time curves. RESULTS: The peak SNR in the lungs was comparable between gadobutrol and Gd-DTPA at all dose levels (15.7 vs. 15.5 at 0.1 mmol/kg bw; 12.9 vs. 12.5 at 0.05 mmol/kg bw; 7.6 vs. 8.9 at 0.025 mmol/kg bw). A dose of 0.1 mmol/kg achieved the highest peak SNR compared with all other dose levels (P < 0.05). A higher peak SNR was observed in gravity dependent lung (P < 0.05). Despite different injection volumes, transit times of the contrast bolus did not differ between both agents. CONCLUSION: Higher concentrated gadolinium chelates offer no advantage over standard 0.5 M Gd-DTPA for contrast-enhanced 3D MRI of lung perfusion.

Adolescent↗

Renal embolization: feasibility of magnetic resonance-guidance using active catheter tracking and intraarterial magnetic resonance angiography.

RATIONALE AND OBJECTIVES: Magnetic resonance (MR)-guidance of endovascular interventions offers various advantages, including the absence of ionizing radiation, excellent soft tissue contrast, and multiplanar and functional imaging capabilities. The objective of this study was to assess the feasibility of MR-guided renal embolization using active catheter tracking with automatic slice positioning and intraarterial contrast-enhanced MR angiography (MRA). MATERIALS AND METHODS: MR-guided embolization of 16 kidneys was attempted in 15 pigs using real-time tracking of active 5-Fr. catheters. Embolization was monitored by selective intraarterial projection MRA. Intraarterial three-dimensional (3D) MRA was used for the assessment of embolization results. Additional pathologic correlation was available in 2 animals. The image quality of intraarterial 3D contrast-enhanced-MRA was rated by an independent radiologist who was not involved in the animal experiments. RESULTS: Active catheter tracking with automatic slice positioning allowed reliable catheter guidance and catheterization of the renal artery in all animals. Embolization was successful in all kidneys (11 left, 5 right), as verified by intraarterial 3D contrast-enhanced MRA (ce-MRA) and/or pathology. The image quality of intraarterial 3D ce-MRA was rated excellent in 10 animals, moderate in 4 animals, and poor in 1 animal. CONCLUSION: Renal embolization using active catheter tracking and intraarterial ce-MRA is feasible. Selective intraarterial ce-MRA allows the assessment of blood supply and organ perfusion before, during, and after therapeutic interventions, thereby complementing MR-guided endovascular interventions.

Animals↗

Evaluation of chest motion and volumetry during the breathing cycle by dynamic MRI in healthy subjects: comparison with pulmonary function tests.

RATIONALE AND OBJECTIVES: To investigate diaphragm and chest wall motion during the whole breathing cycle using magnetic resonance imaging (MRI) and a volumetric model in correlation with spirometry. MATERIALS AND METHODS: Breathing cycles of 15 healthy volunteers were examined using a trueFISP sequence (5 slices in 3 planes, 3 images per second). Time-distance curves were calculated and correlated to spirometry. A model for vital capacity (VC), continuous time-dependent vital capacity (tVC), and investigating the influence of horizontal and vertical parameters on tVC was introduced. RESULTS: Time-distance curves of the breathing cycle using MRI correlated highly significant with spirometry (P < 0.0001). VC calculated by the model was similar to VC measured in spirometry (5.00 L vs. 5.15 L). tVC correlated highly significantly with spirometry (P < 0.0001). Vertical parameters had a more profound influence on tVC change than horizontal parameters. CONCLUSIONS: Dynamic MRI is a simple noninvasive method to evaluate local chest wall motion and respiratory mechanics. It widens the repertoire of tools for lung examination with a high temporal resolution.

Adult↗

Asbestos-related pleural disease: value of dedicated magnetic resonance imaging techniques.

OBJECTIVES: We sought to compare respiratory-gated high-spatial resolution magnetic resonance imaging (MRI) and radial MRI with ultra-short echo times with computed tomography (CT) in the diagnosis of asbestos-related pleural disease. METHODS: Twenty-one patients with confirmed long-term asbestos exposure were examined with a CT and a 1.5-T MR unit. High-resolution respiratory-gated T2w turbo-spin-echo (TSE), breath-hold T1w TSE, and contrast-enhanced fat-suppressed breath-hold T1w TSE images with an inplane resolution of less than 1 mm were acquired. To visualize pleural plaques with a short T2* time, a pulse sequence with radial k-space-sampling was used (TE = 0.5 milliseconds) before and after administration of Gd-DTPA. CT and MR images were assessed by 4 readers for the number and calcification of plaques, extension of pleural fibrosis, extrapleural fat, detection of mesothelioma and its infiltration into adjacent tissues, and detection of pleural effusion. Observer agreement was studied with the use of kappa statistics. RESULTS: The MRI protocol allowed for differentiation between normal pleura and pleura with plaques. Interobserver agreement was comparable for MRI and CT in detecting pleural plaques (median kappa = 0.72 for MRI and 0.73 for CT) and significantly higher with CT than with MRI for detection of plaque calcification (median kappa 0.86 for CT and 0.72 for MRI; P = 0.03). Median sensitivity of MRI was 88% for detection of plaque calcification compared with CT. For assessment of pleural thickening, pleural effusion, and extrapleural fat, interobserver agreement with MRI was significantly higher than with CT (median kappa 0.71 and 0.23 for pleural thickening, 0.87 and 0.62 for pleural effusion, and 0.7 and 0.56 for extrapleural fat, respectively; P < 0.05). For detection of mesothelioma, median kappa was 0.63 for MRI and 0.58 for CT. CONCLUSION: High-resolution MR sequences and radial MRI achieve a comparable interobserver agreement in detecting pleural plaques and even a higher interobserver agreement in assessing pleural thickening, pleural effusion, and extrapleural fat when compared with CT.

Aged↗

Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging.

PURPOSE: To evaluate partially parallel three-dimensional (3D) magnetic resonance (MR) imaging for assessment of regional lung perfusion in healthy volunteers and patients suspected of having lung cancer or metastasis. MATERIALS AND METHODS: Seven healthy volunteers and 20 patients suspected of having lung cancer or metastasis were examined with 3D gradient-echo MR imaging with partially parallel image acquisitions (fast low-angle shot 3D imaging; repetition time msec/echo time msec, 1.9/0.8; flip angle, 40 degrees; acceleration factor, two; number of reference k-space lines for calibration, 24; field of view, 500 x 440 mm; matrix, 256 x 123; slab thickness, 160 mm; number of partitions, 32; voxel size, 3.6 x 2.0 x 5.0 mm(3); acquisition time, 1.5 seconds) after administration of 0.1 mmol/kg of gadobenate dimeglumine. In volunteers, 3D MR perfusion data sets were assessed for topographic and temporal distribution of regional lung perfusion. Sensitivity, specificity, accuracy, and positive and negative predictive values for perfusion MR imaging for detecting perfusion abnormalities in patients were calculated, with conventional radionuclide perfusion scintigraphy as the standard of reference. Interobserver and intermodality agreement was determined by using kappa statistics. RESULTS: Topographic analysis of lung perfusion in volunteers revealed a significantly higher signal-to-noise ratio (SNR) of up to 327% in gravity-dependent lung areas. Temporal analysis similarly revealed much shorter lag time to peak enhancement in gravity-dependent lung areas. In patients, perfusion MR imaging achieved high sensitivity (88%-94%), specificity (100%), and accuracy (90%-95%) for detection of perfusion abnormalities. Interobserver agreement (kappa = 0.86) was very good and intermodality agreement (kappa = 0.69-0.83) was good to very good for detection of perfusion defects. A significant difference (P <.0001) in SNR was observed between normally perfused lung (14 +/- 7 [SD]) and perfusion defects (7 +/- 4) in patients. CONCLUSION: Partially parallel MR imaging with high spatial and temporal resolution allows assessment of regional lung perfusion and has high diagnostic accuracy for detecting perfusion abnormalities.

Adult↗

A computer assisted surgical technique for retrograde autologous osteochondral grafting in talar osteochondritis dissecans (OCD): a cadaveric study.

This study describes a new method for the treatment of osteochondritis dissecans (OCD) in the medial talar dome. Ten cadaveric lower extremities were used to develop and evaluate a retrograde osteochondral grafting technique applying computer-assisted surgery. With the help of a computed tomography (CT)-based navigation system, a guide wire was placed from the lateral talar process into the posteromedial talar trochlea where OCD lesions are predominantly located. Cannulated reamers and arthroscopic shavers were used for the preparation of the recipient hole. The grafts, with diameters of 4.5 mm, 6.5 mm or 8.5 mm were harvested from the lateral femoral trochlea and inserted in a retrograde fashion. The last five cadavers were analyzed for accuracy of surface reconstruction and graft stability. For this purpose a medial malleolar osteotomy and a CT scan was performed. We found steps in the joint surface to range from 0.5 mm to 1.5 mm (mean 0.9 mm, SD 0.4) with the graft always below the surrounding cartilage. Graft subsidence occurred at an applied force of 26.4 +/- 4.6 N. This study indicates that osteochondral cylinders can be inserted in a retrograde fashion to reconstruct the posteromedial talus. Good surface congruency and sufficient graft stability can be achieved.

Bone Transplantation↗

Dynamic T1-weighted monitoring of vascularization in human carcinoma heterotransplants by magnetic resonance imaging.

Studies on tumor angiogenesis and antiangiogenic therapies are commonly performed with tumor heterotransplants in nude mice. To monitor therapeutic effects, improved noninvasive analyses of functional data are required, in addition to the assessment of tumor volume and histology. Here, we report on sequential monitoring of vascularization of human squamous cell carcinomas growing as heterotransplants in nude mice using MRI. Using a custom-developed animal coil in a conventional whole-body 1.5 T MRI scanner, dynamic T1w sequences were recorded after i.v. injection of Gd-DTPA in tumors grown for 17, 21, 25, 29 and 33 days. Amplitude and the exchange rate constant (k(ep)) were calculated according to a 2-compartment model, discriminating intravascular and interstitial spaces, and correlated with tumor size and histology. High-resolution imaging of small heterotransplants from 100 to 1,000 mm(3) was achieved, clearly discriminating vital and necrotic areas. Preceding the development of necroses, which were hyperintense in T2w images and confirmed with histology, a local decrease of amplitude and k(ep) values was observed. Significantly higher amplitudes were found in tumor periphery than in central parts, correlating well with the vascular pattern obtained by immunocytochemistry. Tumor size correlated negatively with amplitude, probably as a result of increasing necrotic areas, whereas the reason for the observed increase of k(ep) value with tumor size remains unclear. These data demonstrate that dynamic MRI is an excellent method for noninvasive assessment of tumor vascularization in small animals using a clinical whole-body scanner with little technical modifications. This technique provides functional data characterizing essential features of tumor biology and is thus appropriate for monitoring antiangiogenic therapies.

Anesthesia, Inhalation↗

High-resolution three-dimensional MR angiography of rodent tumors: morphologic characterization of intratumoral vasculature.

PURPOSE: To evaluate high-resolution three-dimensional MR angiography (MRA) for the visualization and morphologic characterization of intratumoral vasculature. MATERIALS AND METHODS: Two subcutaneous rodent tumor models (human skin carcinoma HaCaT-ras-A-5RT3 grown in nude mice and rat prostate carcinoma R3327-AT1 grown in Copenhagen rats) were examined with a clinical 1.5 T MR-system. For MRA a dedicated high-resolution three-dimensional gradient echo pulse sequence with a voxel size of 166 x 206 x 320 microm(3) was performed after injection of Gadomer-17. The image analysis included a correlation of intratumoral vessels with histology. Signal intensity measurements were performed in the vena cava, the tumor underlying muscle, and in various regions of the tumor. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were calculated from this measurement. RESULTS: High-resolution MRA allowed a clear distinction of intratumoral blood vessels. The mouse tumor model tended to be strongly vascularized with several intratumoral blood vessels clearly displayed by MRA. When correlated with histology, these intratumoral blood vessels had a size in the range of 300 to 400 microm. In contrast, rat tumors had only sparse capillary intratumoral blood vessels that could only be demonstrated by histology. In both tumor models, dilated blood vessels were observed in the subcutaneous tissue near the tumor. In general, areas with a strong contrast enhancement correlated with viable, well vascularized tumor regions, whereas non-enhancing tumor areas correlated with tumor necrosis or hypoxic areas. CONCLUSION: High-resolution three-dimensional MRA allows the visualization of intratumoral vasculature in rodent models. With minimal hardware and software modifications, high-resolution MRA could be performed on a clinical 1.5 T MRI scanner. Morphologic characterization of intratumoral blood vessels could add important insights into the process of tumor angiogenesis.

Animals↗

MRI for the diagnosis of pulmonary embolism.

Pulmonary embolism (PE) is one of the most frequently encountered clinical emergencies. The diagnosis often involves multiple diagnostic tests, which need to be carried out rapidly to assist in the safe management of the patient. Recent strides in computed tomography (CT) have made big improvements in patient management and efficiency of diagnostic imaging. This review article describes the developments in magnetic resonance (MR) techniques for the diagnosis of acute PE. Techniques include MR angiography (MRA) and thrombus imaging for direct clot visualization, perfusion MR, and combined perfusion-ventilation MR. As will be demonstrated, some of these techniques are now entering the clinical arena, and it is anticipated that MR imaging (MRI) will have an increasing role in the initial diagnosis and follow-up of patients with acute PE.

Acute Disease↗

[Automatic slice tracking in interventional magnetic resonance imaging].

Magnetic resonance imaging (MRI) is ideally suited to monitor minimally invasive operations with catheters or needles, since it offers both a superior soft-tissue contrast and the possibility to perform functional tests. In the present study, small radio-frequency coils were attached to the instruments in order to localize the MR-invisible instruments. The implementation of active instrument tracking is described on the basis of the example of active catheter tracking. In this case, the current position information of the instrument is used to automatically position the MRI slice at the catheter location. In combination with a user interface, the interventional radiologist is offered the possibility to perform vascular interventions from within the MR scanner room. At image update rates of approximately 3 Hz, tracking and placement of catheters in vascular structures are possible with interactive switching of slice orientation and image contrast. In an animal model, the technique was successfully used to selectively visualize the abdominal vessels and their branches under MRI guidance.

Animals↗

Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion--initial results.

RATIONALE: Contrast-enhanced magnetic resonance imaging (MRI) of lung perfusion requires a high spatial and temporal resolution. Partially parallel MRI offers an improved spatial and temporal resolution. OBJECTIVE: To assess the feasibility of partially parallel MRI for the assessment of lung perfusion. METHODS: Two healthy volunteers and 14 patients were examined with a contrast-enhanced 3D gradient-echo pulse sequence with partially parallel image acquisitions (TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; voxel size 3.6 x 2.0 x 5.0 mm3, TA: 1.5 seconds). The image analysis included an analysis of the signal-to-noise ratio in the lungs in areas with normal and impaired perfusion. 3D MR perfusion image data were analyzed for perfusion defects and compared with radionuclide perfusion scans, which were available for 10 of 14 patients. RESULTS: The analysis of the 3D perfusion-weighted data allowed a clear differentiation of perfusion abnormalities: MRI showed normal lung perfusion in 9 of 16 cases, whereas perfusion abnormalities were observed in 7 cases. When compared with the radionuclide perfusion scans, a good intermodality agreement was shown (kappa = 0.74). When compared with normally perfused lung a significantly lower signal to noise ratio was observed in hypoperfused lung (7 versus 17; P = 0.02). CONCLUSION: Partially parallel MRI might be used for the assessment of lung perfusion. Future studies are required to further evaluate the diagnostic impact of this technique.

Adult↗