PubMed Health⌕ Search

Biomedical subjects

Christian Geppert

Publications and source records attributed to Christian Geppert.

5 recordsLinked to original sources

Fast 3D 1H spectroscopic imaging at 3 Tesla using spectroscopic missing-pulse SSFP with 3D spatial preselection.

Three-dimensional (3D) (1)H MR spectroscopic imaging (SI) allows metabolic changes in human tissue to be identified. In clinical practice, fast acquisition techniques are required to achieve an adequate spatial resolution within acceptable total measurement times. In this study a novel fast pulse sequence for 3D (1)H SI based on the condition of steady-state free precession (SSFP), termed "spectroscopic missing-pulse SSFP" (spMP-SSFP), is proposed. It combines 3D spatial preselection with the acquisition of full spin echoes (SEs), and thus makes subsequent phase correction of spectra redundant. The sequence was applied to a phantom and healthy human brains in vivo at 3 Tesla. Metabolic images are acquired with a spatial resolution of 1.8 cm(3) within a total measurement time of about 6 min. With a lower signal-to-noise ratio (SNR) per unit measurement time compared to previous spectroscopic SSFP implementations, 3D spatial preselection can now be realized with spMP-SSFP. Since the method does not require separate techniques for water and lipid suppression, and employs a simple data-processing approach, spMP-SSFP is a robust, fast SI method that requires only minimal user interaction.

Brain↗

Fast 1H spectroscopic imaging using steady state free precession and spectral-spatial RF pulses.

Recently, new methods for fast (1)H spectroscopic imaging based on the condition of steady state free precession (SSFP) were introduced to achieve a high signal-to-noise ratio at short minimum measurement times. In this work, a major improvement is presented to overcome a crucial drawback in some of the former sequences: the lack of spatial selectivity. Good spectral selectivity at very high sampling efficiency can be achieved by using spectral-spatial RF pulses, and combined with localised shimming. Results are shown from both phantom experiments and in vivo studies on the rat brain acquired at 4.7 T.

Animals↗

Fast 3D echo planar SSFP-based 1H spectroscopic imaging: demonstration on the rat brain in vivo.

A fast proton spectroscopic imaging pulse sequence based on the condition of steady-state free precession is presented. High 3D spatial and temporal resolution is achieved using simultaneous detection of both one spatial and one spectral dimension, with a time-dependent gradient cycle known from echo planar imaging. Additionally, in order to increase the spectral width of the measurement, an interleaved acquisition scheme is shown either for systems with limited gradient switching capabilities or applications with a wide chemical shift range. The pulse sequence is implemented on a standard 4.7-T nuclear magnetic resonance animal imaging system. Measurements with a total measurement time of less than 2.5 min and a nominal voxel size of 6.75 microl using a total of 64 x 32 x 16 voxels are performed on phantoms and healthy rat brain in vivo allowing the rapid detection of signals from both uncoupled and J-coupled spin systems with high signal-to-noise ratio.

Animals↗

PRESS-based proton single-voxel spectroscopy and spectroscopic imaging with very short echo times using asymmetric RF pulses.

Modified point-resolved spectroscopy (PRESS) sequences for single voxel spectroscopy (MRS) and spectroscopic imaging (SI) with very short echo time ( T(E)) are described using asymmetric radio-frequency (RF) pulses as well as an optimized design and timing of the PRESS sequence. The proposed sequences were implemented on a standard 4.7 T imaging system yielding a T(E) of 6.0 ms only. Simulations and experimental data measured on phantoms and the rat brain in vivo are presented for MRS and SI showing a high signal-to-noise ratio and hardly any phase distortions caused by J-coupling.

Algorithms↗

Fast proton spectroscopic imaging using steady-state free precession methods.

Various pulse sequences for fast proton spectroscopic imaging (SI) using the steady-state free precession (SSFP) condition are proposed. The sequences use either only the FID-like signal S(1), only the echo-like signal S(2), or both signals in separate but adjacent acquisition windows. As in SSFP imaging, S(1) and S(2) are separated by spoiler gradients. RF excitation is performed by slice-selective or chemical shift-selective pulses. The signals are detected in absence of a B(0) gradient. Spatial localization is achieved by phase-encoding gradients which are applied prior to and rewound after each signal acquisition. Measurements with 2D or 3D spatial resolution were performed at 4.7 T on phantoms and healthy rat brain in vivo allowing the detection of uncoupled and J-coupled spins. The main advantages of SSFP based SI are the short minimum total measurement time (T(min)) and the high signal-to-noise ratio per unit measurement time (SNR(t)). The methods are of particular interest at higher magnetic field strength B(0), as TR can be reduced with increasing B(0) leading to a reduced T(min) and an increased SNR(t). Drawbacks consist of the limited spectral resolution, particularly at lower B(0), and the dependence of the signal intensities on T(1) and T(2). Further improvements are discussed including optimized data processing and signal detection under oscillating B(0) gradients leading to a further reduction in T(min).

Animals↗