PubMed Health⌕ Search

Biomedical subjects

Christian Loewe

Publications and source records attributed to Christian Loewe.

At least 19 recordsLinked to original sources

Balloon angioplasty versus implantation of nitinol stents in the superficial femoral artery.

BACKGROUND: Because stent implantation for disease of the superficial femoral artery has been associated with high rates of late clinical failure, percutaneous transluminal angioplasty is preferred for endovascular treatment, and stenting is recommended only in the event of suboptimal technical results. We evaluated whether primary implantation of a self-expanding nitinol (nickel-titanium) stent yielded anatomical and clinical benefits superior to those afforded by percutaneous transluminal angioplasty with optional secondary stenting. METHODS: We randomly assigned 104 patients who had severe claudication or chronic limb ischemia due to stenosis or occlusion of the superficial femoral artery to undergo primary stent implantation (51 patients) or angioplasty (53 patients). Restenosis and clinical outcomes were assessed at 6 and 12 months. RESULTS: The mean (+/-SD) length of the treated segment was 132+/-71 mm in the stent group and 127+/-55 mm in the angioplasty group. Secondary stenting was performed in 17 of 53 patients (32 percent) in the angioplasty group, in most cases because of a suboptimal result after angioplasty. At 6 months, the rate of restenosis on angiography was 24 percent in the stent group and 43 percent in the angioplasty group (P=0.05); at 12 months the rates on duplex ultrasonography were 37 percent and 63 percent, respectively (P=0.01). Patients in the stent group were able to walk significantly farther on a treadmill at 6 and 12 months than those in the angioplasty group. CONCLUSIONS: In the intermediate term, treatment of superficial-femoral-artery disease by primary implantation of a self-expanding nitinol stent yielded results that were superior to those with the currently recommended approach of balloon angioplasty with optional secondary stenting. (ClinicalTrials.gov number, NCT00281060.).

Aged↗

Endovascular repair of the thoracic aorta necessitating anchoring of the stent graft across the arch vessels.

OBJECTIVE: The purpose of the study was to determine technical and clinical results in endovascular repair of thoracic aortic diseases necessitating stent-graft anchoring across the arch vessels. METHODS: The causes for endovascular treatment in 58 patients (aged 20 to 84 years) were aneurysms (n = 32), acute type A (n = 2) and type B dissections (n = 17), posttraumatic transections (n = 4), iatrogenic dissection (n = 1), and penetrating ulcers with an intramural hematoma (n = 2). Surgical revascularization of arch vessels was performed in 26 patients before stent-graft implantation. Intentional overstenting of the left subclavian artery resulted in complete occlusion in 8 and was partial in 24 patients. RESULTS: The 30-day mortality rate was 3.4%. Overall, 19 major postprocedural complications occurred in 14 (24%) patients. Among patients with left subclavian artery occlusion, 2 patients had major (1 paraplegia, 1 critical arm ischemia), and 3 minor (2 temporary vertebrobasilary symptoms, 1 transient arm claudication) complications. Fourteen (25%) patients had an early endoleak, of whom 5 were treated successfully with a secondary endovascular procedure, 2 necessitated open surgical conversion, and 7 were treated conservatively, with spontaneous sealing of the endoleak in 3. In 53 (91%) in whom computed tomographic follow-up was longer than 3 months (mean, 30.1 months, range, 3 to 85), the aortic diameter along the stented segment decreased in 24, was stable in 19, and increased in 10 patients. CONCLUSION: Fixation of the stent graft in the aortic arch can expand the applicability of endovascular repair. Intentional overstenting should be performed with caution to avoid ischemic problems after complete occlusion of left subclavian artery.

Adult↗

Endovascular repair of inflammatory aortic aneurysms: long-term results.

OBJECTIVE: Our objective was to report the long-term follow-up results of endovascular aneurysm repair of inflammatory aortic aneurysms. CONCLUSION: Endovascular aneurysm repair of inflammatory aortic aneurysms excludes the aneurysm and seems to reduce the size of the aneurysmal sac and the extent of periaortic fibrosis with acceptable periinterventional and long-term morbidity.

Aged↗

MRA versus DSA in the assessment of occlusive disease in the aortic arch vessels: accuracy in detecting the severity, number, and length of stenoses.

PURPOSE: To compare the diagnostic accuracy of contrast-enhanced magnetic resonance angiography (MRA) to that of digital subtraction angiography (DSA) in the detection, grading, and measurement of atherosclerotic stenoses involving the aortic arch arteries. METHODS: The MRA and DSA studies from 28 patients (16 women; mean age 61.6 years, range 24-83) being evaluated for possible aortic arch vessel disease were examined. The aortic arch vasculature was divided into 9 segments; within each segment, the presence and severity of stenotic or occlusive disease was determined based on a 5-point scale. In addition, stenosis length and distance to the branch were measured in 5-mm increments. Image quality was assessed using a 5-point scale. The accuracy, sensitivity, and specificity values, as well as the positive and negative predictive values in MRA's identification of lesions, were evaluated in comparison to DSA. RESULTS: In 28 patients, 189 segments were assessed by both methods. Of these, 173 were correctly rated by MRA, resulting in an accuracy of 91.5%. The accuracy dropped slightly to 86.5% when 11 "not assessable" lesions were included. Sensitivity and specificity for severity measurement were 88.5% and 95.6%, respectively. In 39 of 45 lesions, stenosis length measurements were identical by both methods, but there was a difference of 0.5 cm each in 6 lesions. CONCLUSIONS: MRA as compared to DSA shows high accuracy in the detection and grading of lesions involving the aortic arch vessels. The noninvasive nature of this method recommends its use for screening, treatment planning, and follow-up in known or suspected arterial disease in aortic arch arteries.

Adult↗

Usefulness of magnetic resonance imaging of cardiac and paracardiac masses.

In this study, magnetic resonance imaging was compared with histology to evaluate the usefulness of magnetic resonance imaging to distinguish malignant from benign cardiac and paracardiac masses in 55 patients. Tumor location, tissue composition, and pericardial or pleural effusion all were identified as key predictors of lesion type. Observers were accurate in the prediction of lesion type (area under curve 0.88 and 0.92), and there was good interobserver variability (Cohen's kappa = 0.64).

Adolescent↗

Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography.

The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive disease. A total of 203 patients were examined in a prospective, multi-centre study at 1.0/1.5 T. Ten vessel segments of one leg were evaluated on-site and by three independent blinded reviewers off-site. One hundred eighty-two patients were evaluable in blinded reading. For pelvis and thigh, there was statistically significant diagnostic agreement between CE MRA and i.a. DSA on-site (94%) and off-site (86-88%). Overall, for detection of clinically significant stenoses, 93% sensitivity and 90% specificity were achieved in on-site evaluation, with 71-76 and 87-93% off-site; for detection of occlusion, sensitivity and specificity on-site were 91 and 97%, with 75-82 and 94-98% off-site. Evaluation was more sensitive on-site than off-site for detection of stenoses and occlusion, whereas specificity was similar. The CE MRA with 1.0-mol gadobutrol gave results comparable to those of i.a. DSA for the larger arteries of pelvis and thigh. Results for calf arteries were compromised by spatial resolution and technical limitations.

Angiography, Digital Subtraction↗

Peripheral MR angiography.

Peripheral arterial occlusive disease is a chronic and progressive disease with a reported incidence rate from 4.5% to 8.8% in men over 55 years of age. The diagnosis is usually made clinically, but for treatment planning and control, imaging of the peripheral arteries is required. Since its introduction in 1994, contrast-enhanced MR angiography has demonstrated a high diagnostic confidence and has replaced the invasive intra-arterial DSA, which is still the current gold standard for many different indications. For the peripheral arteries, clinical use of MR angiography was hampered for some years by the unsolved problem of the large imaging volume and the small diameter of the distal arteries. However, since the availability of ultra-fast high-gradient sequences and the possibility of moving-bed imaging, contrast-enhanced MR angiography, over the last few years, has shown its enormous potential and high accuracy in the diagnosis and follow-up of patients suffering from peripheral arterial occlusive disease. Exciting innovations in hardware and software allows very fast, very accurate, and very robust noninvasive imaging of the peripheral arteries, and both treatment planning as well as follow-up can be performed using contrast-enhanced MR angiography. The following review introduces the basic concepts of peripheral MR angiography--focusing on contrast enhanced imaging--and presents the different techniques as well as some potential limitations and how they could be solved. Finally, this article provides a look into the already-begun future of peripheral contrast-enhanced MR angiography with hybrid and combination techniques.

Arterial Occlusive Diseases↗

Contrast material-enhanced, moving-table MR angiography versus digital subtraction angiography for surveillance of peripheral arterial bypass grafts.

PURPOSE: To assess the accuracy of moving-table MR angiography (MRA) in the evaluation of peripheral bypass grafts. MATERIALS AND METHODS: There were 39 patients who had had peripheral bypass graft surgery and then subsequently underwent digital subtraction angiography (DSA) and contrast material-enhanced MRA, which was performed with moving-table software on a 1.0-T system before and during administration of 40 mL gadolinium. For evaluation, every bypass graft was divided into three parts and every leg into 14 segments. Disease severity was scored in four categories (0%-29%, 30%-69%, 70%-99%, 100%). Results were compared with those of the DSA. A total of 147 bypass graft segments and 938 vessel segments were classified. RESULTS: In 132 of the assessable 147 bypass segments, disease gradings with both methods were congruent; however, 13 stenoses were misinterpreted by MRA for one grade and two additional lesions by two grades, leading to an accuracy in precise stenoses detection of 89.9%. The sensitivity and specificity values in the detection of bypass graft stenoses >69% (grade 3 + 4 lesions) reached 90.0% and 98.3%, respectively. In 821 of 938 vessel segments the accuracy of MRA in stenoses detection reached 87.5%. The sensitivity and specificity values in the detection of grade 3 + 4 lesions were 95.6% and 94.0% for the native vessels, respectively. CONCLUSION: Moving-table MRA was as accurate in assessing bypass grafts as it was for the native arteries and showed a great accuracy in stenosis detection compared with DSA. Therefore, MRA is a promising modality for bypass graft surveillance and might be a noninvasive alternative to DSA in this regard.

Aged↗

Permanent transarterial embolization of neuroendocrine metastases of the liver using cyanoacrylate and lipiodol: assessment of mid- and long-term results.

OBJECTIVE: The purpose of our study was to assess the results of hepatic artery embolization using N-butyl-2-cyanoacrylate and ethiodized oil for the treatment of small-bowel neuroendocrine metastases to the liver as part of a multimodality protocol for the treatment of liver metastases from neuroendocrine small-bowel tumors. MATERIALS AND METHODS: Twenty-three patients underwent permanent embolization of the hepatic artery using cyanoacrylate and Lipiodol for treatment of liver metastases after radical resection of small-bowel neuroendocrine tumors. All patients received additional treatment including somatostatin, and most patients received interferon as well. Cumulative survival rates were estimated using the Kaplan-Meier method. RESULTS: Overall, 75 embolizations (range, 1-10; mean, 3.3) were performed. Median survival time was 69 months, and the estimated cumulative survival rates reached 95.7% and 65.4% for 1 and 5 years, respectively. Two deaths (8.7%) occurred within 1 month of treatment, and one patient experienced a vascular complication at the time of embolization. CONCLUSION: Permanent embolization of hepatic arteries as part of a multimodality treatment protocol is beneficial in long-term follow-up for patients with metastasized small-bowel neuroendocrine tumors. The use of cyanoacrylate as an embolic agent is safe and effective.

Adult↗

[Diagnostic management of nipple discharge].

Nipple discharge may be a symptom of a variety of diseases. The importance of nipple discharge is its possible association with breast carcinoma. Not only the precise clinical evaluation but also particularly imaging evaluation by mammography, ultrasound, galactography or MR-galactography is necessary to establish the exact diagnosis and plan proper treatment. Depending on the underlying pathology--most commonly intraductal papilloma, fibrocystic changes or breast carcinoma--the optimal therapeutic regimen, such as single lactiferous duct excision on the one end and modified radical mastectomy on the other end of the spectra may be chosen.

Breast Cyst↗

[Factors influencing quality of mammograms].

Due to its outstanding role for screening and diagnosis of breast cancer, optimizing the quality of mammographies was in the main focus of interest within the past two decades. However, there exist additional, non-technical factors influencing diagnostic confidence of mammograms, which were usually not part of discussions concerning mammographic image quality. Nevertheless, these non-technical factors are of great interest into the female population. Information and instruction of the patient prior to mammography helps to increase the compliance of the patient during mammography, and thus not only cooperation during examination is optimized, but also cooperation in the screening program. Furthermore, timing the examination within the first part of the menstrual cycle and regarding specific patient-related factors can decrease pain and discomfort during mammography, which will increase image quality.

Austria↗

Safety of contrast-enhanced MR angiography employing gadobutrol 1.0 M as contrast material.

Our objectives were to evaluate the safety of intravenous 1.0-M gadobutrol injections in patients with an indication for contrast-enhanced magnetic resonance angiography (CE MRA) of supra-aortal, pelvic, or peripheral arteries by examining and assessing adverse events, laboratory values, vital signs and ECG findings for clinical significance. In 435 patients, recruited in three multicenter trials for safety evaluations of the new contrast agent 1.0-M gadobutrol, CE MRA was performed with 1.0- to 1.5-T scanners using three-dimensional gradient-echo sequences and phased-array coils. The study population comprised 312 men and 123 women with a mean age of 60.9 years. Two hundred seven patients had an indication for imaging of body arteries and 228 had an indication for imaging of peripheral arteries. Blood laboratory values and urinalysis results of 124 patients as well as heart rate, blood pressure, and 12-lead-electrocardiogram readings of 93 patients obtained during a follow-up period of up to 72 h after the injection of contrast media were available for safety analysis. Contrast media application was performed as intravenous bolus injection of 1.0-M gadobutrol in fixed doses according to the patients' body weight (b.w.) and indication for CE MRA and was followed by a 20- to 40-ml saline flush. Mean dose actually applied was 0.1 0.27 mmol/kg b.w. Flow rate ranged between 0.2 and 2.0 ml/s. Safety evaluations found a good tolerability with only 4.6% of at least "possibly related" adverse reactions and no clinically relevant changes in blood and urine samples including no transmetallation effect on serum zinc values. Analysis of renal tolerance showed no influence on renal function irrespective of preexisting renal impairment. The ECG analysis (rhythm analysis, pace-setting disturbances, conduction disturbances, and time interval measurements, including uncorrected and corrected QT) showed no clinically relevant effect of the injection of 1.0-M gadobutrol on the cardiac conduction system. Intravenous injection of 1.0-M gadobutrol at a dose of up to 0.1 0.27 mmol/kg b.w. in the indication CE MRA is safe and causes no clinically relevant changes in safety parameters such as heart rate, blood pressure, blood and urine laboratory values, and cardiac conduction system.

Adult↗

MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms.

Our objective was to evaluate the accuracy of contrast-enhanced 3D MR angiography (MRA) in the follow-up of patients with endoluminally treated aortic aneurysms and correlate these findings with uni- or biphasic CT angiography (CTA). Forty MR angiograms in 32 patients with implanted aortic nitinol stent grafts were compared to CTA. Twenty-two MR examinations were correlated with arterial-phase CTA (uniphasic), and 18 MR examinations were correlated with biphasic CTA. Uniphasic CTA demonstrated three type-1/type-3 endoleaks and four reperfusion (type-2) endoleaks. In addition, MRA depicted two type-2 reperfusion endoleaks that were missed by CTA. Using biphasic CTA, two type-1/type-3 endoleaks and three reperfusion (type-2) endoleaks were detected; of those, delayed scanning detected three reperfusion (type-2) endoleaks missed during arterial-phase CTA. In addition to the findings by CTA, MRA depicted another type-2 reperfusion endoleak. Magnetic resonance angiography is at least as sensitive as uni- or biphasic CTA for detecting endoleaks and may consequently offer advantages in patients with contraindications to iodinated contrast agents.

Aged↗

Renal artery PTA and stent implantation: immediate and late clinical and morphological outcome.

BACKGROUND: Renal artery stenosis (RAS) is a potentially curable cause of secondary hypertension, but the indications for interventional treatment of renovascular hypertension are still a matter of debate. The aim of the study was to investigate immediate and long-term results of percutaneous renal artery revascularization (PTRA). Primary technical success, peri-intervention complications, patency, the course of arterial hypertension and renal function were analyzed. METHODS: 32 renal interventions in 24 consecutive patients (15 PTA, 17 stents) were investigated in a retrospective cohort study. Comorbidities, interventional data and serum creatinine were recorded. Patients were followed for a median period of 45 months (IQR, 32 to 68). Clinical evaluation of the course of blood pressure, serum creatinine, Doppler ultrasound evaluation and multi-slice spiral-CT angiography were performed at follow-up. RESULTS: Primary technical success was achieved in 30 interventions (94%), and in 2 patients during a secondary intervention. The rate of complications was 16% (n = 5). Three major complications were encountered (9%): 1 renal artery thrombosis and 2 acute renal failures. Three patients developed late renal failure after 1, 4 and 37 months, but the overall serum creatinine levels remained stable during the observation period. Hypertension was improved after intervention in 17 patients (71%). However, recurrent hypertension was found in 9 patients (38%) after a median period of 49 months (IQR, 47 to 96). Patency rates at 12, 24 and 72 months were 94%, 94% and 64%, respectively. CONCLUSION: Renal artery PTA can be performed with an acceptable rate of major complications and good long term morphological results. However, clinical outcome in terms of sustained improvement of hypertension is moderate.

Aged↗

MRA of the lower extremities in patients with pulmonary embolism using a blood pool contrast agent: initial experience.

PURPOSE: To evaluate the feasibility of blood pool contrast-enhanced magnetic resonance angiography (MRA) to visualize the arterial and venous vessel tree and to detect deep venous thrombosis (DVT) of the lower extremities. MATERIALS AND METHODS: Nine consecutive patients with pulmonary embolism (mean age = 46 +/- 9) were randomized to various doses of NC100150 (between 0.75 and 6 mg of Fe/kg of body weight). A T1-weighted (T1W) 3D gradient recalled echo (GRE) sequence (TE = 2.0 msec, TR = 5.0 msec) was used. Two observers blinded to the dose of contrast agent assessed image quality, contrast attenuation, and appearance of thrombi. RESULTS: Qualitative assessment of overall MRA image quality and semiquantitative vessel scoring revealed good to excellent delineation of venous and arterial vessel segments independent of the dose of NC100150. However, quantitative region of interest analysis revealed a significantly higher signal-to-noise ratio (SNR) in the high-dose group than in the mid- and low-dose groups of NC100150 (P < 0.01). Between dose groups, the SNR was independent of vessel type (artery or vein) and vessel segment localization (proximal or distal). All seven venous thrombi (mean length = 7.2 +/- 0.95 cm) were characterized by a very low signal intensity (SI), which was only 16.6 +/- 7% of the SI in adjacent venous segments (P < 0.0001). CONCLUSION: High-quality MR angiograms of the lower extremities can be obtained using low concentrations of NC100150 in combination with a strong T1W 3D GRE sequence. The obvious delineation of venous thrombi suggests that this technique may be potentially used as a noninvasive "one-stop shopping" tool in the evaluation of thromboembolic disease.

Adult↗

Arterial embolization of unresectable hepatocellular carcinoma with use of cyanoacrylate and lipiodol.

PURPOSE: To assess the potential of transarterial permanent embolization with use of a mixture of cyanoacrylate and lipiodol for treatment of unresectable primary hepatocellular carcinoma (HCC). MATERIALS AND METHODS: In a retrospective study, 36 patients with histologically proven HCC were treated with transarterial embolization (TAE) of the hepatic arteries. None of these patients were candidates for surgical resection and some had advanced disease with multinodular disease or bulky tumor, thrombosis of a segmental branch of the portal vein, and/or extrahepatic spread. To induce permanent and more peripheral embolization, cyanoacrylate, an adhesive polymerizing on contact with blood, was used in TAE. From 1990 to 1998, a total of 76 embolization procedures were performed. Cumulative survival rates were calculated. RESULTS: Most of the patients presented with a self-limited postembolization syndrome. Severe procedure-related complications were found after four treatment sessions (5.2%). The 30-day perioperative mortality rate was 2.7%. The mean follow-up period was 20.3 months (range, 1-68 mo), with a median survival of 26 months. The median survival was also estimated for different Okuda stages of disease: stage II (n = 26) versus stage III (n = 5) disease (32 vs 9 months; P <.05); patients with (n = 9) or without (n = 27) extrahepatic metastasis (10 vs 26 months; P <.05); and patients with (n = 10) or without (n = 26) thrombosis of a segmental branch of the portal vein (7 versus 34 months [P <.005]). CONCLUSION: TAE with use of cyanoacrylate and lipiodol for unresectable HCC is a feasible treatment modality. This retrospective report indicates beneficial effects on survival even in patients with advanced disease.

Adult↗

Biocompatibility and performance of the Wallstent and the Wallgraft, Jostent, and Hemobahn stent-grafts in a sheep model.

PURPOSE: Three recently developed stent-grafts and the Wallstent were compared directly in an ovine animal model with regard to performance and biocompatibility. MATERIALS AND METHODS: Three stent-grafts, the Hemobahn (polytetrafluoroethylene [ePTFE]/nitinol), Wallgraft (polyester/Ni-Co-Ti-steel alloy), and Jostent peripheral stent-graft (balloon-expandable ePTFE/stainless steel), and the Wallstent (Ni-Co-Ti-steel alloy), were implanted in sheep iliac arteries (one type of each stent or stent-graft per animal, n = 8). Pre- and postimplantation luminal diameters were measured for each prosthesis and implantation site. Angiography, intravascular ultrasonography (IVUS), and histomorphometric, histologic, and scanning electron microscopic analyses were performed at 3 months. RESULTS: Early lumen gain, late lumen loss, and patent vessel diameter at angiography were not significantly different. Two stent-grafts had significantly more neointima formation (Hemobahn, 9.88 mm(2) +/- 0.94; Wallgraft, 14.98 mm(2) +/- 0.90) than the other stent-graft (Jostent, 6.52 mm(2) +/- 0.46) and the Wallstent (5.24 mm(2) +/- 0.62; P <.01). Patent lumen area was not significantly different (Hemobahn, 42.57 mm(2) +/- 1.41; Jostent, 39.76 mm(2) +/- 2.04; Wallgraft, 40.22 mm(2) +/- 1.04; Wallstent, 41.64 mm(2) +/- 1.59; P =.57). The Hemobahn had significantly more inflammatory reaction (inflammation score of 0.83 +/- 0.03) than the Jostent (0.58 +/- 0.03), Wallgraft (0.55 +/- 0.04), or Wallstent (0.16 +/- 0.01). Angiography and IVUS demonstrated absence of anastomotic neointima formation. Endothelialization was incomplete and immature for all prostheses. CONCLUSIONS: The stent-grafts caused a greater degree of neointima formation and inflammatory vessel wall reaction than the bare stent. However, these changes did not interfere with patent lumen areas and occurred in the absence of excessive anastomotic neointima formation.

Alloys↗

Peripheral vascular occlusive disease: evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients.

OBJECTIVE: The purpose of our study was to compare contrast-enhanced moving-bed MR angiography and digital subtraction angiography in the evaluation of peripheral vascular occlusive disease. MATERIALS AND METHODS: This retrospective report includes 106 patients (45 women, 61 men) with known or suspected peripheral vascular occlusive disease who underwent MR angiography and intraarterial digital subtraction angiography of the peripheral arteries. MR angiography was performed on a 1.0-T unit using a moving-bed technique. Every leg was divided into 14 vascular segments, and severity of disease was scored in four categories. Digital subtraction angiography was the standard of reference. RESULTS: In the 106 patients, 2378 vessel segments were evaluated with both imaging modalities. In 2156 segments, MR angiography and digital subtraction angiography were concordant for stenosis classification, in 188 segments the two modalities differed in one category, and in 24 segments they differed in two categories. MR angiography achieved sensitivity and specificity of 96.7% and 95.8%, respectively, for differentiating nonsignificant from hemodynamically significant stenosis (kappa = 0.91). CONCLUSION: This study indicates that MR angiography is an accurate imaging modality in clinical practice. Our data support the concept that MR angiography can modify the diagnosis of suspected peripheral vascular occlusive disease.

Adult↗