A biomechanical analysis of sublaminar and subtransverse process fixation using metal wires and polyethylene cables.

STUDY DESIGN: An in vitro biomechanical calf thoracic spine study. OBJECTIVE: To evaluate the biomechanical stability of sublaminar and subtransverse process fixation using stainless steel wires and ultra-high molecular weight polyethylene (UHMWPE) cables. SUMMARY OF BACKGROUND DATA: It is commonly held that transverse process fixation provides less stability than sublaminar fixation. To our knowledge, this is the first biomechanical study to compare the stability afforded by sublaminar fixation and subtransverse process fixation using metal wire and UHMWPE cable before and after cyclic loading. METHODS: There were 6 fresh-frozen calf thoracic spines (T4-T9) used to determine the sublaminar fixation stiffness and subtransverse process fixation stiffness in each group. Double strands of 18-gauge stainless steel wire, 3 and 5 mm-width UHMWPE cable (Nesplon; Alfresa, Inc., Osaka, Japan) were applied to each spine. Cyclic pure flexion-extension moment loading (2 Nm, 0.5 Hz, 5000 cycles) was applied after the initial stability was analyzed by measuring the range of motion. Statistical analyses were used to delineate differences between the various experimental groups. RESULTS: Subtransverse process wiring was more stable than sublaminar wiring after cyclic loading in flexion-extension (P < 0.05). There were no significant differences between each group in lateral bending and axial rotation after cyclic loading. Sublaminar stainless steel wiring was more stable than sublaminar 3 and 5-mm cable before and after cyclic loading in axial rotation (P < 0.01). Acute subtransverse process fixation using 3-mm cable was less stable after cyclic loading in axial rotation (P < 0.05). All other groups did not produce statistically significant differences. CONCLUSIONS: Subtransverse process fixation provides at least as much stability as sublaminar fixation. A 5-mm UHMWPE cable and stainless steel wire result in equivalent sublaminar and subtransverse process stability.

Animals↗

The effects of rod contouring on spinal construct fatigue strength.

STUDY DESIGN: In vitro fatigue loading using a corpectomy model outfitted with posterior pedicle screw instrumentation. OBJECTIVE: The purpose of this study was to detect differences in fatigue resistance of titanium and stainless steel spinal constructs that use rods contoured using a French Bender, and to compare differences in fatigue resistance of contoured and straight titanium rods. SUMMARY OF BACKGROUND DATA: Instrumentation failure is generally thought to be caused by fatigue or cyclic loading. Intraoperative contouring of the posterior rods is almost always required to match the native kyphotic (thoracic) or lordotic (cervical or lumbar) spinal curvature. How bending these rods affects their overall fatigue resistance is not well described. In addition, changes in fatigue resistance may be a function of material type. METHODS: Spinal constructs were evaluated using the ASTM F1717-01 model. Two different titanium-based rods (Ti6AL4V and CpTi) and two different steel-based rods (Orthinox and 316L stainless steel) were evaluated in this study (n = 6 for each group). Rods were contoured at two points using a French Bender and were rigidly coupled to polyaxial pedicle screws within UHMWPE vertebral bodies. Constructs were cycled at a load ratio of 10 between a minimum and maximum loading regime of -250 N/-25 N and -700 N/-70 N at a frequency of 4 Hz. Estimated maximum nominal stresses at various points of interest in the spinal constructs were calculated using beam theory. Effects of the rod material, load, and stress on the number of cycles to failure were analyzed using Cox proportional hazards regression. RESULTS: All of the spinal constructs with contoured CpTi rods and contoured Ti6Al4V rods failed at one of the bends in the rods. Almost all of the spinal constructs with straight CpTi rods and straight Ti6Al4V rods failed where the blocker screw fastens the rod to the coupler of the polyaxial screw head. Contoured titanium constructs demonstrated significantly lower fatigue life than contoured 316L constructs. Contouring tended to lower the fatigue life of both the Ti6Al4V and CpTi constructs. CONCLUSION: Intraoperative rod contouring using a French Bender significantly reduces the fatigue life of titanium spinal constructs.

Bone Nails↗

Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation.

BACKGROUND: Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. METHODS: Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. RESULTS: No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p < 0.05). The ultimate tensile load was significantly higher for double-row fixation (287 +/- 24 N) than for all of the single-row fixations (p < 0.05). Additionally, the massive cuff stitch (250 +/- 21 N) was found to have a significantly higher ultimate tensile load than the two-simple (191 +/- 18 N) and arthroscopic Mason-Allen (212 +/- 21 N) stitches (p < 0.05). No significant differences in stiffness were found among the stitches. Failure mechanisms were similar for all stitches. Rotator cuff repairs in the anterior half of the greater tuberosity had a significantly lower peak-to-peak elongation and higher ultimate tensile strength than did repairs on the posterior half. CONCLUSIONS: In this in vitro cadaver study, double-row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.

Adult↗

Pedicle screw fixation of the thoracic spine: an in vitro biomechanical study on different configurations.

STUDY DESIGN: An in vitro biomechanical study of different pedicle screw configuration usage on the thoracic spine using a cadaveric model. OBJECTIVES: To investigate the degree of motion afforded different pedicle screw configurations in the thoracic spine using a cadaveric model with 2 different degrees of intrinsic stability. SUMMARY OF BACKGROUND DATA: Recently, thoracic pedicle screws have become an alternative to hook and wire fixation, and have gained popularity. Clinically, pedicle screw use has ranged from application to every segment, to skipping every other level. There exists no clear consensus as to which strategy is most appropriate. METHODS: The load-displacement behavior of 6 different constructs was determined on 8 fresh frozen cadaver spine specimens (T4-T12). Each construct was evaluated on 2 destabilization models, including minimum destabilization (bilateral facetectomy) and maximum destabilization (facetectomy and annulotomy). Pure moments were applied, and the resultant range of motion for each scenario was determined. RESULTS: Facetectomy did not significantly destabilize the thoracic spine. Annulotomy and facetectomy created gross instability that rendered testing of this destabilization model impossible. All constructs significantly reduced the range of motion compared to intact or facetectomized specimens (P < or = 0.001). When different constructs were compared to each other, a pattern of continuously increasing stability emerged, with the "maximum" construct being the most stable and "minimum" configuration being the least, with varying degrees of statistical significance. CONCLUSIONS: Our results suggest that the most important factor for the acute postoperative stability of spinal fixation is the degree of preoperative or iatrogenic destabilization. The minimum amount of pedicle screws provides adequate stability when there is minimal destabilization of the spine. On the other hand, when anterior column release has been performed or instability exists before surgery, segmental pedicle screw fixation may be necessary to achieve adequate stability.

Aged↗

Biomechanical comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion performed at 1 and 2 levels.

STUDY DESIGN: Biomechanical laboratory study of human cadaveric spines. OBJECTIVE: To determine the difference in acute stability between posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF) performed at 1 and 2 levels with and without posterior fixation. SUMMARY OF BACKGROUND DATA: Circumferential spinal fusion with both an interbody graft and posterior pedicle screw-rod construct has been advocated to decrease pseudarthrosis rates. Both PLIF and TLIF theoretically allow for 3-column fixation and fusion. METHODS: Specimens underwent either PLIF or TLIF at L2-L3 (single-level) and L3-L4 (2-level), both with and without pedicle screw instrumentation. During TLIF, an interbody allograft was placed in the anterior or middle column. Nondestructive, nonconstraining pure moment loading was applied to each specimen. RESULTS: There were no significant differences in the range of motion after either PLIF or TLIF at 1 level. The addition of pedicle screws tended more strongly to increase rigidity after 1-level PLIF compared to TLIF. Position of the TLIF graft did not affect stability. The addition of pedicle screws to a 2-level construct significantly reduced all motions tested. CONCLUSIONS: Based on our findings, posterior fixation with a pedicle screw-rod construct is suggested for 1-level PLIF and TLIF, and is necessary to achieve stability after interbody fusion across 2 levels using either technique.

Biomechanical Phenomena↗

Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation.

STUDY DESIGN: An in vitro biomechanical study of C1-C2 posterior fusion techniques using a cadaveric model. OBJECTIVES: To investigate the acute stability afforded across the atlantoaxial segment by a novel technique that uses intralaminar screws in C2, and to compare these results to the stability obtained using a C2 pedicle fixation technique. SUMMARY OF BACKGROUND DATA: There are numerous techniques available for rigidly coupling C1 and C2. It has been shown that screw techniques provide higher acute stability than wiring practices. However, many of these methods that use screw fixation in C2 can be technically difficult, especially in cases in which there is an aberrant vertebral artery course or if the C2 pedicle is not large enough to accommodate the instrumentation. A novel technique that uses intralaminar screws in C2 with C1 pedicle screws and bilateral longitudinal rods has been recently developed in an effort to overcome many of these issues. To date, there are no published reports as to whether this new technique provides equivalent (or better) fixation to the currently accepted methods. METHODS: Six fresh-frozen human cadaveric cervical spines (C0-C4) were used in this study. Specimens were tested in their intact condition after destabilization via odontoidectomy, and after implantation of 3 different fixation constructs: (1) the Harms technique, 2 pedicle screws in C2, (2) a single C2 pedicle screw and a single C2 intralaminar screw, and (3) a construct having bilateral intralaminar C2 screws. Pure moment loading in flexion/extension, lateral bending, and axial rotation was applied to the occiput. Subsequent relative intervertebral rotations were determined using a 3 camera system. Range of motion for the intact, destabilized, and 3 fixation scenarios was determined, and statistical analysis was performed using one-way analysis of variance Fisher least-significant-difference post hoc test for multiple comparisons. RESULTS: The data indicate that odontoidectomy significantly increased C1-C2 motion in flexion/extension and lateral bending. All 3 fixation techniques significantly reduced motion compared to the intact and destabilized cases. There were no statistically significant differences between the C2 intralaminar and pedicle screw techniques. CONCLUSIONS: The results clearly indicate the potential of the intralaminar screw technique to provide stability that is equivalent to methods currently used. Given the serious complications that can follow vertebral artery injury and the decreased likelihood of injury by avoiding placement of C2 pedicle screw(s) and C1-C2 transarticular screw(s), strong consideration should be given to using a construct that incorporates C2 intralaminar screw(s).

Atlanto-Axial Joint↗

The effect on anterior column loading due to different vertebral augmentation techniques.

BACKGROUND: Vertebral compression fractures are a significant cause of morbidity amongst the elderly, resulting in pain, kyphosis, decreased mobility, and often depression. The two most popular operative treatments of compression wedge fractures are vertebroplasty and kyphoplasty, however, which method leads to restoration of normal spinal loading is unknown. METHODS: A cadaveric thoracolumbar spine model was fractured and then treated using one of two techniques: vertebroplasty or kyphoplasty. Three non-destructive loading regimes were applied to the intact, fractured and treated cases. Sub-adjacent nuclear pressure, used as a measure of anterior column loading, was determined for each experimental variant and loading case. FINDINGS: The data indicate that nuclear pressure was substantially reduced after the spine was fractured. These pressures were minimally increased after treatment, however, not to the level of the pre-fractured condition. In all loading cases, there were no significant differences between the two treatment types. INTERPRETATION: While our data show that both vertebroplasty and kyphoplasty allow the disc to generate higher nuclear pressures, neither treatment increased nucleus pulposus pressure above the level of the intact state. This directly relates to the clinical condition in that adjacent segment fractures sustained subsequent to either treatment is likely the result of overall disease progression, and not a direct result of the intervention.

Adult↗

Cervical spine arthroplasty biomechanics.

The advent of cervical intervertebral disc replacement represents an exciting and new frontier in the treatment of myelopathy and discogenic pain. The goal of most disc arthroplasty designs is to attempt to approximate the normal spinal motion as much as possible. This survey article provides a general overview as to the goals of cervical disc replacement, the current state of knowledge concerning how these devices have been evaluated, and a commentary on future work that should be performed to characterize these devices fully.

Arthroplasty, Replacement↗

Intervertebral disc replacement maintains cervical spine kinetics.

STUDY DESIGN: An in vitro biomechanical study of C4-C5 intervertebral disc replacement using a cadaveric model. OBJECTIVES: To investigate the degree of motion afforded by a ball-and-socket cervical intervertebral disc prosthesis design. SUMMARY OF BACKGROUND DATA: Intervertebral disc prostheses designs attempt to restore or maintain cervical disc motion after anterior cervical discectomy and reduce the likelihood of accelerated degeneration in adjacent discs by maintaining normal motion at the affected disc level. Surprisingly, the actual kinetic and biomechanical effects that cervical disc arthroplasty imparts on the spine have not been widely reported. Accordingly, we investigated what effect implanting a cervical disc prosthesis has on the range of motion at the affected level as well as how it changes the coupled motion patterns at the level of implantation. METHODS: Six fresh-frozen human cadaveric cervical spines (C2-C7) were used in this study. We evaluated two different spinal conditions: intact and after disc replacement at C4-C5. Compression (using the follower load concept) and pure moment loading were applied to the specimen. Range of motion was measured using an optical tracking system. Statistical differences between the intact and replaced condition range of motion was determined using analysis of variance with post hoc comparisons (alpha = 0.05). RESULTS: The data indicate that the intervertebral disc prosthesis approximated the intact motion in all three rotation planes at the affected level. Finally, changes in cervical coupled rotations, specifically lateral bending during axial rotation loading and axial rotation during lateral bending loading, were not statistically significant between the two tested conditions. CONCLUSIONS: Our data demonstrate that a ball-and-socket design can replicate physiologic motion at the affected and adjacent levels. More importantly, the data indicate that motion coupling, which is most dramatic in the cervical spine and plays an important biomechanical role, is maintained.

Arthroplasty, Replacement↗

Biomechanics of cervical laminoplasty: kinetic studies comparing different surgical techniques, temporal effects and the degree of level involvement.

Laminoplasty is a common surgical technique used to treat cervical myelopathy. Both voids and contradictory information exist in the literature with regard to the initial and long-term biomechanical consequences of cervical laminoplasty. In order to clarify the existing literature, as well as provide clinically useful information, we identified three specific aims: (1) to measure the long-term differences in kinetics between the open door laminoplasty (ODL) and French door laminoplasty (FDL) techniques; (2) to delineate differences in primary and long-term cervical motion after laminoplasty; and (3) to determine whether inclusion of additional levels in the laminoplasty procedure results in a change in immediate cervical biomechanics. The study design involved both an animal (caprine) model and in vitro surgical simulation. We kinematically evaluated the cervical spine specimens (C2-C7) by applying pure bending moment loads to the cephalad vertebra (C2), while constraining the caudal vertebra (C7). Resultant intervertebral rotations (C3-C6) were determined via stereophotogrammetry. Overall, the data indicate that both FDL and ODL significantly reduce range of motion 6 months postoperatively, compared with the un-operated spine. There were no significant differences between the two techniques after 6 months. We also showed that ODL produces a significant reduction in motion 6 months postoperatively compared with the immediate postoperative condition. Finally, the data indicated that extending the laminoplasty from two to four levels did not significantly change range of motion. The choice of technique should be based upon the surgeon's experience with these technically demanding procedures. In addition, initial stability considerations should not affect the decision to extend the laminoplasty to adjacent levels. Finally, the data also suggest that early changes in biomechanics should not be a major factor when considering whether immobilization of the cervical spine is necessary after laminoplasty. In fact, our temporal study, as well as previously reported clinical data, indicates that one should expect significantly decreased intervertebral motion 6 months after laminoplasty. Therefore, early physical therapy should be considered to preserve a more physiologic pattern of cervical range of motion.

Animals↗

Stability analysis of craniovertebral junction fixation techniques.

BACKGROUND: Craniovertebral arthrodesis in the upper cervical spine is challenging because of the high degree of mobility afforded by this region. A novel method for achieving atlantoaxial fixation with use of polyaxial screws inserted bilaterally into the lateral masses of C1 and transpedicularly into C2 with longitudinal rod connection has recently been introduced. The question remains as to whether this technique provides adequate stability when extended cephalad to include the occiput. The purpose of this study was to determine the primary stability afforded by this novel construct and compare its stability with the current standard of bilateral longitudinal plates combined with C1-C2 transarticular screws. METHODS: We used ten fresh-frozen human cadaveric cervical spines (C0-C4). Pure moment loads were applied to the occiput, and C4 was constrained during the testing protocol. We evaluated four conditions: (1) intact, (2) destabilized by means of complete odontoidectomy, (3) stabilization with longitudinal plates with C1-C2 transarticular screw fixation, and (4) stabilization with a posterior rod system with C1 lateral mass screws and C2 pedicle screws. Rigid-body three-dimensional rotations were detected by stereophotogrammetry by means of a three-camera system with use of marker triads. The range of motion data (C0-C2) for each fixation scenario was calculated, and a statistical analysis was performed. RESULTS: Destabilization of the specimen significantly increased C0-C2 motion in both flexion-extension and lateral bending (p < 0.05). Both fixation constructs significantly reduced motion in the destabilized spine by over 90% for all motions tested (p < 0.05). No significant differences were detected between the two constructs in any of the three rotational planes. CONCLUSIONS: Both hardware systems provide equivalent construct stability in the immediate postoperative period when it is critical for the eventual success of a craniovertebral arthrodesis. On the basis of this work, we believe that the decision to use either construct should be determined by clinical rather than biomechanical concerns.

Aged↗

Temperature and thermal dose distributions during intradiscal electrothermal therapy in the cadaveric lumbar spine.

STUDY DESIGN: Human cadaveric lumbar spines were used to assess the temperature and thermal dose distribution during intradiscal electrothermal therapy in vitro. OBJECTIVES: To determine whether intradiscal electrothermal therapy produces adequate tissue temperatures to denature annular collagen or ablate nerve cells. SUMMARY OF BACKGROUND DATA: Several hypothesized mechanisms for the effect of intradiscal electrothermal therapy have been suggested and include: 1) shrinkage of the nucleus and/or the annulus fibrosus by contraction of collagen fibers; and 2) thermal ablation of sensitive nerve fibers in the outer annulus. METHODS: Intradiscal electrothermal therapy was performed using the standard clinical protocol on 12 lumbar specimens in a 37.0 degrees C water bath using the SpineCath by Oratec. Temperatures were recorded simultaneously at 40 different locations in the disc. Thermal dose (Equivalent Minutes 43.0 degrees C) was calculated at each temperature point. RESULTS: The highest temperature measured (out of 520 points) was 64.0 degrees C and was within 1 mm of the heating coil. Temperatures in excess of 60 degrees C were all within 1 to 2 mm of the intradiscal electrothermal therapy catheter surface, the 50 to 60 degrees C range extended approximately 6 mm, above 48 degrees C extended approximately 7 mm, and above 45 degrees C extended to approximately 10 mm. Less than 2% of points achieved temperatures sufficient for collagen denaturation (>60 degrees C). On average, 42.5% of points accumulated >250 Equivalent Minutes 43.0 degrees C, a conservative common dose threshold for thermal necrosis of cells. The time history of thermal measurements demonstrated that the disc temperature had not reached steady state by the end of the heating protocol (16.5 minutes). CONCLUSIONS: Except for a very limited margin (1-2 mm) around the catheter, the temperature necessary to induce collagen shrinkage was not observed within the disc. Temperatures sufficient to ablate nerves were developed in some areas but were not reliably produced in clinically relevant regions, such as the posterior annulus. These results suggest that beneficial clinical outcomes may be critically dependent on probe placement or other factors unknown.

Cadaver↗

Scaphoid kinematic behavior after division of the transverse carpal ligament.

PURPOSE: The effect that carpal tunnel release (CTR) has on scaphoid motion has not been reported. Accordingly the purpose of this study was to determine the flexion/extension behavior of the scaphoid during global wrist radial/ulnar deviation before and after division of the transverse carpal ligament (TCL). METHOD: In this study we examined the in vitro kinematics of the scaphoid during wrist deviation in 6 cadaver forearms both before and after the division of the TCL using a computerized camera monitoring system. The specimens were evaluated in 13 different positions, from 20 degrees of radial deviation to 40 degrees of ulnar deviation at increments of 5 degrees. RESULTS: The data indicate that the difference in scaphoid position after TCL division is statistically significant when the wrist is in ulnar deviation of 15 degrees or greater. In addition a significant difference in scaphoid extension between pre- and post-TCL division conditions was found at 5 degrees of radial deviation as well as at 5 degrees or more of ulnar deviation and increased with increasing ulnar deviation. CONCLUSIONS: Scaphoid kinematics are altered considerably in radial-ulnar deviation after division of the TCL. This alteration may have long-term consequences and contribute to commonly seen post-CTR symptoms.

Analysis of Variance↗

Biomechanical testing of posterior atlantoaxial fixation techniques.

STUDY DESIGN: An in vitro biomechanical study of C1-C2 posterior fusion techniques was conducted using a cadaveric model. OBJECTIVE: To investigate and compare the acute stability afforded by a novel rod-based construct that uses direct polyaxial screw fixation to C1 and C2 with contemporary transarticular screw and wire techniques. SUMMARY AND BACKGROUND DATA: Acute stability of the atlantoaxial complex is required to achieve bony consolidation. Various forms of posterior wiring were the first standardized procedures advocated to achieve C1-C2 fixation, but because of insufficient construct stability, these techniques have been coupled with transarticular screw fixation. Significant technical difficulties, however, including the possibility of neurovascular compromise during implantation are associated with transarticular screw placement. A novel technique that uses direct polyaxial screw fixation to C1 and C2 and bilateral longitudinal rods was developed recently. However, there are no published reports detailing the biomechanical characteristics of this new construct. METHODS: In this study, 10 fresh-frozen human cadaveric cervical spines with occiput (C0-C4) were used. Osteoligamentous specimens were tested in their intact condition after destabilization via odontoidectomy, and after two different Gallie wiring techniques. Each specimen was assigned to one of the two screw fixation groups. Five specimens were implanted with the polyaxial screw-rod construct and tested. The remaining five specimens were tested after application of bilateral C1-C2 transarticular screws with Gallie wiring (Magerl-Gallie technique). Pure-moment loading, up to 1.5 Nm in flexion and extension, right and left lateral bending and right and left axial rotation, was applied to the occiput, and relative intervertebral rotations were determined using stereophotogrammetry (motion analysis system). Range of motion data for all fixation scenarios were normalized to the destabilized case, and statistical analysis was performed using one-way analysis of variance with Fisher's least significant difference PLSD post hoc test for multiple comparisons. RESULTS: The data indicate that destabilization via odontoidectomy significantly increased C1-C2 motion. Both screw techniques significantly decreased motion, as compared with both Gallie wiring methods in lateral bending and axial rotation (P < 0.02 for all) and tended toward reduced motion in flexion-extension. There was no statistically significant difference between the two screw techniques. CONCLUSIONS: The results clearly indicate the screw-rod system's equivalence in reducing relative atlantoaxial motion in a severely destabilized upper cervical spine, as compared with the transarticular screw-wiring construct. These findings mirror the previously reported clinical results attained using this new screw-rod construct. Thus, the decision to use either screw construct should be based on safety considerations rather than acute stability.

Adult↗

Fixation of osteoporotic distal fibula fractures: A biomechanical comparison of locking versus conventional plates.

The increased use of locking plates to treat difficult fracture scenarios has been advocated in patients that have reduced bone mineral density. One of these difficult fracture patterns, fixation of the distal fragment of a distal fibula fracture, may depend on unicortical and cancellous bony purchase. This study investigated the construct stiffness afforded by using locking and conventional plating schema in a cadaveric model. Overall, the data indicate that a locking plate construct with two distal unicortical screws was mechanically equivalent to standard plating with 3 distal screws. In addition, fixation with the standard plates was dependent on bone mineral density (BMD) whereas the locking plate fixation was independent of BMD. The clinical implication of this study is that locking plates may be advantageous in patients with the most severe osteoporosis.

Aged↗