Remote detection of incessant slow VT with an ICD capable of home monitoring.

In this case report, we present a 57-year-old patient who suffered from incessant slow ventricular tachycardia because of a change in therapy 2 weeks after the implantation of an implantable cardioverter defibrillator (ICD) with Home Monitoring (HM). HM is a fully automatic and wireless system capable of transmitting device data including episode counters. The patient had mild symptoms with only short episodes of dizziness and would not have contacted the primary care centre. Due to HM, the arrhythmia was detected before the next routine follow-up, and the patient was seen the next day. HM made it possible to adjust the dosage of the newly established beta-blocker treatment in an outpatient setting and avoid hospitalization. HM yields the potential for remote detection of arrhythmias in ICD recipients, allowing alterations in device programming or medication.

Defibrillators, Implantable↗

Atrial linear lesions: feasibility using cryoablation.

BACKGROUND: Long linear lesions are created in the left atrium to modify the atrial substrate, thereby curing atrial fibrillation. The creation of long linear left atrial lesions using radiofrequency (RF) ablation is time consuming and difficult. Furthermore, it might result in significant complications. Cryoablation might overcome some of the disadvantages of RF ablation. Therefore, the aim of our study was to assess whether the creation of a long linear lesion is possible using cryotherapy. METHODS: A right atrial septal linear lesion was created in six pigs (median weight: 50 kg; range: 40-60 kg). The ablation procedure was performed with a 7-F Freezor cryocatheter. The nonfluoroscopic mapping system LocaLisa was used as a navigation tool. At each point, freezing was maintained at the lowest attainable temperature (-75 degrees C) for 4 minutes. The CARTO system was used for the evaluation of the linear lesions. Furthermore, all animals were sacrificed immediately after the ablation procedure and a postmortem examination of the lesions was performed. Additionally, an analysis of the amplitudes of the intracardiac electrograms registered via the ablation catheter was performed before and after the ablation procedure. RESULTS: A right atrial septal linear lesion could be created successfully in all six pigs. For the performance of this ablation line, a median number of 16 cryoapplications (range, 11-26) was necessary. The amplitudes of the intracardiac electrograms registered via the ablation catheter decreased significantly after ablation. The CARTO bipolar voltage map revealed very low potentials along the ablation line and showed a sharply demarcated ablation area at the septum in all pigs. Further analysis of the CARTO map revealed an incomplete conduction block in all cases. Most of the pigs had a small gap close to the fossa ovalis. The postmortem examination of 2,3,5-triphenyl-tetrazolium chloride-stained specimens showed sharply demarcated lesions without any ulcerations. There were no major complications during the procedure. CONCLUSIONS: The creation of long linear lesions using cryoablation is feasible and safe. Lesion characteristics are different and more favorable than those created by RF. However, the aim of creating a transmural lesion and a complete conduction block remains an unsolved problem even with current cryoablation techniques. Nevertheless, growing experience and technical improvements might overcome some of the current limitations of this new technique.

Animals↗

Discordant regulation of CRP and NT-proBNP plasma levels after electrical cardioversion of persistent atrial fibrillation.

BACKGROUND: B-type natriuretic peptide (BNP) and C-reactive protein (CRP) have been suggested to be prognostically relevant markers in patients with cardiovascular disease. Additionally, BNP and CRP plasma levels seem to be independently elevated in patients with atrial fibrillation (AF). However, there are only sparse data about the significance and temporal course of these plasma markers after restoration of sinus rhythm (SR). METHODS: We performed a prospective study in consecutive patients with symptomatic atrial fibrillation. NT-proBNP and CRP plasma levels were measured before and one month after electrical cardioversion (CV). Patients with infections, an acute coronary syndrome, or surgery 4 weeks prior to CV, were excluded. RESULT: Twenty-five patients (men 84%, age 66 +/- 8 years, duration of AF 90 +/- 75 days, left ventricular ejection fraction 0.57 +/- 0.11) were analyzed. At follow-up (33 +/- 6 days after CV) 14 patients (56%) were in SR and 11 patients (44%) in AF. In patients with SR there was a significant reduction of NT-proBNP levels (baseline 1647 +/- 1272 pg/mL, follow-up 772 +/- 866 pg/mL, P < 0.05), even in a subgroup of patients (n = 10) with normal left ventricular ejection fraction (1262 +/- 538 vs 413 +/- 344 pg/mL, P < 0.001). CRP levels in patients with SR were similar at baseline and at follow-up (3.5 +/- 3.6 vs 3.2 +/- 2.5 mg/L, P = 0.8). CONCLUSION: We conclude that even in patients with normal left ventricular ejection fraction restoration of sinus rhythm leads to a significant reduction of NT-proBNP plasma levels. In contrast, CRP plasma levels seem not to be influenced during the first 4 weeks after electrical cardioversion.

Aged↗

Visualization of pulmonary vein stenosis after radio frequency ablation using multi-slice computed tomography: initial clinical experience in 33 patients.

PURPOSE: Radio frequency ablation (RFA) of the pulmonary veins (PV) is an established technique for treatment of atrial fibrillation (AF). However, stenoses within the treated areas are well known complications. Thus, a reliable non-invasive diagnosis of PV stenosis would be an important step forward in the care of these patients (pts). Aim of the present study was the diagnostic accuracy of new multi-slice detected computed tomography (MSCT) in visualization of PV and in detecting PV stenosis. MATERIAL AND METHODS: A total of 33 pts (17 male, 16 female, mean age 57+/-10.2 years [40-71]) were included. Retrospectively ECG-gated CT angiography (CTA) was performed within 1 day to a maximum of 380 days after RFA with a MSCT scanner. Interpretation of the scan was performed on conventional contrast enhanced axial slices and on 3D volume rendering images (maximum intensity projection: MIP, multi-planar reconstruction: MPR). Lesion severity was determined on a semi-quantitative scale (mild: <20%, intermediate: 20-50%, severe >50%) and compared to conventional angiography which had been performed at the beginning and at the end of RFA. RESULTS: MSCTA was applied without any complications, and all treated pulmonary veins (n=73) could be visualized. Diagnostic image quality was obtained in all examinations. A significant stenosis was detected by conventional angiography in 26/73 (36%) PV (2/73 (3%) severe, 14/73 (19%) intermediate, 10/73 (14%) mild). Using MSCTA, only 13 stenosis in 73 treated PV could be visualized (1/73 (1%) severe, 6/73 (8%) intermediate, 6/73 (8%) mild). CONCLUSIONS: Multi-slice-detector CT is able to visualize PV and to detect PV stenoses. However, stenosis severity seems to be underestimated and not all lesions could be accurately detected. Larger studies have to be performed to further assess the diagnostic accuracy and clinical reliability of this new non-invasive method and to focus on the incidence of PV stenosis following RFA especially in long-time follow up.

Adult↗

Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds.

Transvenous unipolar active can defibrillation systems have proven to be effective in treating ventricular tachyarrhythmias. However, a further reduction of ventricular defibrillation thresholds (V-DFT) would increase the longevity, reduce the size of pulse generators, and help to avoid additional leads in patients with inacceptable high V-DFTs. In a finite difference computer model, the extension of the right ventricular (RV) defibrillation coil into the low right atrium led to a 40% reduction of unipolar V-DFT. To evaluate this finding, we conducted a prospective, randomized study in 11 patients receiving an ICD. Extension of the RV electrode was simulated by adding a second coil placed in the low right atrium with the same polarity. Using a binary search protocol, V-DFT was determined with and without the additional electrode in each patient. Total shock impedance was significantly lower in the two coil (low RA) configuration, compared to the single coil (RV) configuration. Corresponding values were 49.9 +/- 6.7 Ohm and 61.1 +/- 9.3 Ohm, respectively (P < 0.01, paired t-test). However, there was no reduction, but even a nonsignificant increase in V-DFTs. Mean V-DFT in the RV configuration was 12.0 +/- 5.6 J and 16.3 +/- 7.8 J in the low RA configuration (P = 0.09, paired t-test). Despite a reduction in total impedance, the addition of a defibrillation coil in the low right atrium does not reduce ventricular defibrillation thresholds.

Aged↗

Long-term experience with subcutaneous ICD leads: a comparison among three different types of subcutaneous leads.

ICDs provide protection against sudden cardiac death in patients with life-threatening arrhythmias. Nevertheless, efficacy of defibrillation remains an important issue to guarantee the future safety of patients who receive an ICD. There is a significant number of patients who need an additional subcutaneous lead to obtain a defibrillation safety margin of at least 10 J between the maximum output of the ICD and the energy needed for ventricular defibrillation. However, few data exists about the long-term performance of different types of subcutaneous leads. Therefore, the aim of this study was to analyze the long-term experience with three different types of subcutaneous leads. The study included 132 patients (109 men, 23 women; mean age 59.8 years [SD +/- 10.7 years]). All of them received a subcutaneous lead in addition to a single chamber or dual chamber ICD between October 1990 and April 2002. Two patients received a second subcutaneous lead after the first lead had been removed so that a total of 134 subcutaneous leads were evaluated. Inclusion criteria for the implantation of an additional subcutaneous lead were (1) unsuccessful ventricular defibrillation at implant without a subcutaneous lead, (2) insufficient safety margin (< 10 J) between the maximum output of the ICD and the energy needed for ventricular defibrillation, or (3) clinical evaluation of a new subcutaneous lead (Medtronic 13014). There were no significant differences between the three study groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The results of the DFT testing during follow-up (prehospital discharge test and 1 and 3 years) were compared to the baseline value obtained during the implantation procedure. All lead related complications were analyzed. Eighty-two single element subcutaneous array electrodes (SQ-A1), 31 subcutaneous three-finger electrodes (SQ-A3), and 21 subcutaneous patch electrodes (SQ-P) were implanted during the study period. The median follow-up was 1,499 days (25th percentile: 798 days, 75th percentile: 1,976 days) in the SQ-A1 group, 2,209 days (25th percentile: 1,242 days, 75th percentile: 2,710 days) in the SQ-A3 group, and 1,419 days (25th percentile: 787 days, 75th percentile: 2,838 days) in the SQ-P group. None of the three groups had a significant change of the DFT during follow-up compared to baseline. Major complications occurred in six (7.3%) patients in group SQ-A1 and in two (9.5%) patients in group SQ-P. There were no major complications in group SQ-A3. Kaplan-Meier curves analyzing freedom from subcutaneous lead related complications did not show a significant difference between the three study groups (P = 0.16). SQ-A1, SQ-A3, and SQ-P leads provide stable DFTs during long-term follow-up. Major complications are rare. However, a careful follow-up including chest radiographs at regular intervals is needed to detect potentially fatal complications like lead fractures.

Defibrillators, Implantable↗

Effects of the chromanol HMR 1556 on potassium currents in atrial myocytes.

PURPOSE: The chromanol HMR 1556 is a potent blocker of KvLQT1/minK potassium channels expressed in Xenopus oocytes. The compound is therefore a new class III antiarrhythmic drug with a distinct mechanism of action. However, the effect of HMR 1556 on atrial ion channels and the selectivity of block in the human heart has not been investigated. We tested the effects of HMR 1556 on repolarizing potassium currents in human and guinea pig atrial myocytes. METHODS AND RESULTS: Single atrial myocytes were isolated by enzymatic dissociation. Atrial potassium currents (I(Ks), I(Kr), in guinea pig, I(to), I(Kur), I(K1) in humans) were recorded at 36 degrees C in the whole cell mode of the patch clamp technique. HMR 1556 produced a concentration-dependent and reversible block of I(Ks) with a half maximal concentration (EC(50)) of 6.8 nmol/l. 10 micromol/l HMR 1556 almost completely inhibited I(Ks) (97.2+/-3.2%, n=6). Steady-state activation as well as kinetic properties of the current were not altered by HMR 1556. I(Kr) currents were not affected up to concentrations of 10 micromol/l. HMR 1556 did not inhibit other potassium currents in human atrium: I(to), I(Kur) and the classical inward rectifier potassium current I(K1) were not significantly affected up to concentrations that completely blocked I(Ks) (10 micromol/l). CONCLUSIONS: HMR 1556 is a highly-potent blocker of I(Ks) channels without exerting effects on other potassium currents involved in atrial repolarization. Given the potential advantages of I(Ks) vs. I(Kr) blockade, the drug's new mechanism of action warrants further investigation to clarify its role as an antiarrhythmic agent.

Aged↗

Delayed sodium channel inactivation mimics long QT syndrome 3.

DPI 201-106 delays sodium channel inactivation. Acute administration of DPI 201-106 prolonged the QT interval, provoked spontaneous torsades de pointes in one patient, and facilitated stimulation-induced polymorphic ventricular tachyarrhythmias in two patients. Similar to the observations in animal studies, delaying sodium channel inactivation is a new form of the acquired long QT syndrome, mimicking long QT syndrome type 3.

Cardiotonic Agents↗

beta3-Adrenergic regulation of an ion channel in the heart-inhibition of the slow delayed rectifier potassium current I(Ks) in guinea pig ventricular myocytes.

OBJECTIVES: I(Ks), the slow component of the delayed rectifier potassium current, underlies a strong beta-adrenergic regulation in the heart. Catecholamines, like isoproterenol, induce a strong increase in I(Ks). Recent work has pointed to an opposing biological effect of beta(1)- and beta(3)-adrenoceptors in the heart. However the role of these subtypes in the regulation of cardiac ion channel function is unknown. METHODS: We investigated the effects of beta(1)- and beta(3)-adrenoceptor modulation on I(Ks) in guinea-pig ventricular myocytes, using patch-clamp techniques. RESULTS: Superfusion with 100 nmol/l isoproterenol increased the step current amplitude by 81.3+/-8.0%. In contrast, after block of beta(1)- (1 micromol/l atenolol) and beta(2)-receptors (1 micromol/l ICI118,551), isoproterenol induced a reduction of the step current amplitude by 34.3+/-3.5%. The beta(3)-selective agonist BRL37344 significantly reduced the I(Ks) step current at +70 mV in a concentration-dependent manner (IC(50): 5.01 nmol/l). In the presence of bupranolol (beta(1)-, beta(2)- and beta(3)-adrenoceptor antagonist), the effect of BRL37344 was markedly attenuated, from 27.3+/-5.6% (100 nmol/l BRL37344 alone) to 4.0+/-1.3% (100 nmol/l BRL37344+1 micromol/l bupranolol). BRL37344 (100 micromol/) did not alter current amplitudes of KvLQT1/minK expressed in CHO cells or in Xenopus oocytes, excluding a direct effect of BRL37344 on the channel. 1 micromol/l BRL37344 mildly prolonged action potentials in guinea pig ventricle (APD(90):+7.8%) CONCLUSIONS: We have demonstrated a functional coupling between the beta(3)-adrenoceptor and ion channel function in the mammalian heart. Our findings point to a potential role for beta(3)-adrenoceptors in cardiac electrophysiology and pathophysiology.

Action Potentials↗

Efficacy of metoprolol and sotalol in the prevention of recurrences of sustained ventricular tachyarrhythmias in patients with an implantable cardioverter defibrillator.

ICDs provide protection against sudden cardiac death in patients with life-threatening ventricular arrhythmias. Nevertheless, most ICD recipients receive adjunctive antiarrhythmic drug therapy to reduce the number of recurrent episodes and ICD discharges. The aim of the study was to compare the efficacy of metoprolol and d,l-sotalol in preventing VT/VF recurrences in patients with an ICD in a prospective, randomized trial. One hundred patients (83 men, 17 women; mean age 59 years, SD +/- 11 years) were randomized to receive metoprolol or sotalol after implantation of an ICD. There were no significant differences between the two groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The median follow-up was 728 days (25th percentile: 530 days, 75th percentile: 943 days) in the metoprolol group and 727 days (25th percentile: 472 days, 75th percentile: 1,223 days) in the sotalol group (P = 0.52). Thirty-three patients treated with metoprolol and 30 patients receiving sotalol had at least one episode during the follow-up. Event-free survival curves were generated for the two treatment arms using the Kaplan-Meier method and showed no significant difference (P = 0.68). Eight patients treated with metoprolol and six patients treated with sotalol died during follow-up. Total mortality was not significantly different between the two study groups (P = 0.43). Metoprolol is as efficacious as sotalol in preventing VT/VF recurrences in patients with an ICD.

Defibrillators, Implantable↗

Is it safe to program a long tachycardia detection interval?

Implantable cardioverter defibrillator (ICD) therapy is used frequently in patients with "slow" ventricular tachycardia (VT). Hence, the tachycardia detection interval is programmed within the range of the physiologic heart rate, but this may cause serious problems. If a fast VT is converted to sinus tachycardia with a cycle length shorter than the tachycardia detection interval, the episode is not terminated and the success counter is not reset. If this happens repeatedly, therapies will be exhausted without termination of the episode. If VT recurs within such an episode, it will not be treated. This report describes a patient who died suddenly in a scenario similar to the one described. Although all documented VT/ventricular fibrillation episodes were terminated by the device, the episode was not terminated because of the ongoing supraventricular tachycardia. Therefore, no further therapies were available and the patient probably died of fast untreated VT. Programming of a long tachycardia detection interval is dangerous in currently available ICDs.

Aged↗

Use of beta-blockers in atrial fibrillation.

Atrial fibrillation is the most common arrhythmia in the general population and is frequently associated with organic heart disease. beta-adrenoceptor antagonists (b-blockers) are very effective in preventing atrial fibrillation after coronary artery bypass surgery. It has been shown recently that the beta-blocker metoprolol controlled release/extended release (CR/XL) is also effective in maintaining sinus rhythm after conversion of atrial fibrillation. There is concern that class I antiarrhythmic drugs, such as quinidine, disopyramide, and flecainide in particular, may increase mortality. The risk of proarrhythmia associated with beta-blocker treatment is very low. Therefore b-blockers, such as metoprolol CR/XL, may be the first line of treatment to maintain sinus rhythm, especially after myocardial infarction and in patients with chronic heart failure and in those with arterial hypertension. In patients with persistent atrial fibrillation, AV-nodal conduction-slowing drugs, such as calcium channel antagonists and beta-blockers are used to control the ventricular rate during atrial fibrillation. Several studies clearly show that beta-blockers alone, or in combination with digoxin are very effective in controlling the ventricular rate at rest and during exercise. beta-blockers are effective in maintaining sinus rhythm and controlling the ventricular rate during atrial fibrillation. Given these effects and their favorable effects on mortality, beta-blockers should be considered as first-line agents in the management of patients with atrial fibrillation.

Adrenergic beta-Antagonists↗