PubMed Health⌕ Search

Biomedical subjects

Christian Rankl

Publications and source records attributed to Christian Rankl.

6 recordsLinked to original sources

Visualization of single receptor molecules bound to human rhinovirus under physiological conditions.

Dynamic force microscopy (DFM) was used to image human rhinovirus HRV2 alone and complexed with single receptor molecules under near physiological conditions. Specific and site-directed immobilization of HRV2 on a model cell membrane resulted in a crystalline arrangement of virus particles with hexagonal symmetry and 35 nm spacing. High-resolution imaging of the virus capsid revealed about 20 resolvable structural features with 3 nm diameters; this finding is in agreement with protrusions seen by cryo-electron microscopy. Binding of receptor molecules to individual virus particles was observed after injection of soluble receptors into the liquid cell. Virus-receptor complexes with zero, one, two, or three attached receptor molecules were resolved. The number of receptor molecules associated to virions increased over time. Occasionally, dissociation of single receptor molecules from viral particles was also observed.

Capsid↗

Dynamic force microscopy for imaging of viruses under physiological conditions.

Dynamic force microscopy (DFM) allows imaging of the structure and the assessment of the function of biological specimens in their physiological environment. In DFM, the cantilever is oscillated at a given frequency and touches the sample only at the end of its downward movement. Accordingly, the problem of lateral forces displacing or even destroying bio-molecules is virtually inexistent as the contact time and friction forces are reduced. Here, we describe the use of DFM in studies of human rhinovirus serotype 2 (HRV2) weakly adhering to mica surfaces. The capsid of HRV2 was reproducibly imaged without any displacement of the virus. Release of the genomic RNA from the virions was initiated by exposure to low pH buffer and snapshots of the extrusion process were obtained. In the following, the technical details of previous DFM investigations of HRV2 are summarized.

Journal Article↗

Twelve receptor molecules attach per viral particle of human rhinovirus serotype 2 via multiple modules.

The crystallographic T = 1 (pseudo T = 3) icosahedral symmetry of the human rhinovirus capsid dictates the presence of 60 identical, symmetry related surface structures that are available for antibody and receptor binding. X-ray crystallography has shown that 60 individual very-low density lipoprotein receptor (VLDLR) modules bind to HRV2. Their arrangement around the fivefold axes of the virion suggested that tandem oligomers of such modules could attach simultaneously to symmetry-related sites. By resolving virus particles carrying various numbers of artificial recombinant concatemers of VLDLR repeat 3 (V33333) by capillary electrophoresis and extrapolation of the measured mobilities to that at saturation of all binding sites, we present evidence for up to 12 molecules of the concatemer to bind one single virion.

Electrophoresis, Capillary↗

Hydrodynamic damping of a magnetically oscillated cantilever close to a surface.

We studied the frequency response of a magnetically driven atomic force microscope (AFM) cantilever close to a sample surface in liquids. Amplitude-frequency (tuning) curves showed pronounced differences in dependence on the tip-sample separation (from 1 to 50 microm), with significant shifts of the resonance peak. A model was developed in which the cantilever was described in a full shape manner and the hydrodynamic forces acting on the cantilever were approximately calculated. The slight inclination of the cantilever to the surface (alpha approximately 15 degrees) leads to a force profile along the cantilever. Therefore, the mathematical problem can be strictly solved only numerically. For an approximate analytical solution, the hydrodynamic force profile was approximated by a constant force along the cantilever for large separations and by a point force acting on the tip of the cantilever for small separations. The theoretical results calculated within this model agreed well with the experimental data and allowed to determine the cantilever mass in liquid M*, the joint mass at the tip end m*t, and the coefficient of viscous interaction of the cantilever with free liquid, gamma(infinity).

Journal Article↗

Imaging morphological details and pathological differences of red blood cells using tapping-mode AFM.

The surface topography of red blood cells (RBCs) was investigated under near-physiological conditions using atomic force microscopy (AFM). An immobilization protocol was established where RBCs are coupled via molecular bonds of the membrane glycoproteins to wheat germ agglutinin (WGA), which is covalently and flexibly tethered to the support. This results in a tight but non-invasive attachment of the cells. Using tapping-mode AFM, which is known as gentle imaging mode and therefore most appropriate for soft biological samples like erythrocytes, it was possible to resolve membrane skeleton structures without major distortions or deformations of the cell surface. Significant differences in the morphology of RBCs from healthy humans and patients with systemic lupus erythematosus (SLE) were observed on topographical images. The surface of RBCs from SLE patients showed characteristic circular-shaped holes with approx. 200 nm in diameter under physiological conditions, a possible morphological correlate to previously published changes in the SLE erythrocyte membrane.

Erythrocyte Membrane↗

Dynamic force microscopy imaging of native membranes.

We employed magnetic ACmode atomic force microscopy (MACmode AFM) as a novel dynamic force microscopy method to image surfaces of biological membranes in their native environments. The lateral resolution achieved under optimized imaging conditions was in the nanometer range, even when the sample was only weakly attached to the support. Purple membranes (PM) from Halobacterium salinarum were used as a test standard for topographical imaging. The hexagonal arrangement of the bacteriorhodopsin trimers on the cytoplasmic side of PM was resolved with 1.5nm lateral accuracy, a resolution similar to images obtained in contact and tapping-mode AFM. Human rhinovirus 2 (HRV2) particles were attached to mica surfaces via nonspecific interactions. The capsid structure and 2nm sized protein loops of HRV2 were routinely obtained without any displacement of the virus. Globular and filamentous structures on living and fixed endothelial cells were observed with a resolution of 5-20nm. These examples show that MACmode AFM is a favorable method in studying the topography of soft and weakly attached biological samples with high resolution under physiological conditions.

Capsid↗