PubMed Health⌕ Search

Biomedical subjects

Christian W Huck

Publications and source records attributed to Christian W Huck.

At least 19 recordsLinked to original sources

A new analytical material-enhanced laser desorption ionization (MELDI) based approach for the determination of low-mass serum constituents using fullerene derivatives for selective enrichment.

60]fullerene derivatives (dioctadecyl methano[60]fullerene, [60]fullerenoacetic acid, and IDA-[60]fullerene) were prepared and subjected to a comprehensive characterization study including protein binding properties and capacity. These fullerene derivatives were successfully applied as material-enhanced laser desorption/ionization (MELDI) carrier materials. It is shown that diverse functionalities result in characteristic human serum peak patterns (m/z 2000-20 000) in terms of signal intensity as well as the number of detectable masses. In addition, the fullerene derivatives clearly provided differences in the low molecular weight mass region (m/z 1000-4000) after elution of the adsorbed serum constituents, and [60]fullerenoacetic acid was the most effective carrier material. Novel high-speed, monolithic, high-resolution capillary columns, prepared by thermally initiated copolymerization of methylstyrene (MSt) and 1,2-bis(p-vinylphenyl)ethane (BVPE) were employed for eluate separation and target spotting. Thus, serum compounds in the low-mass range were successfully fractionated and subjected to MALDI-MS/MS analysis. This contribution, hence, proposes a new "top-down" strategy for proteome research enabling protein profiling as well as biomarker identification in the low-mass range using selective enrichment, high-resolution separation, and offline MALDI-MS/MS evaluation.

Adsorption↗

Mass spectrometric identification of serum peptides employing derivatized poly(glycidyl methacrylate/divinyl benzene) particles and mu-HPLC.

Biomarkers play a key role in preclinical screening and diagnosis of a disease. Various support materials are utilized for this task, in combination with MALDI-TOF-MS. The way to effectively bind serum contents and their profiling is well-elaborated by the material-enhanced laser desorption ionization (MELDI) approach. In this particular work, focus is placed on the development of a strategy to identify low molecular weight serum peptides. Poly(GMA/DVB) is derivatized in a way to achieve an affinity termed as immobilized metal ion affinity chromatography (IMAC). Iminodiacetic acid (IDA) is used as a chelating ligand, whereas copper (Cu2+) acts as a metal ion for complexing peptides and proteins out of blood serum. Polymer binds the serum compounds over a broad mass range, which includes low mass peptides and high mass albumin (66 kDa). Bound contents are eluted from material by an acetonitrile/trifluoroacetic acid mixture, which proves the reversible nature of metal and amino acid linkage. Polystyrene/divinyl benzene (PS/DVB) monolithic capillary column is used for fractionation through RP-HPLC, prior to the target spotting. The tandem TOF fragment ion mass spectra of each fraction is acquired and used to search against the Swiss-Prot database, using the Mascot search engine for the identification of peptides.

Amino Acid Sequence↗

Material-enhanced laser desorption/ionization (MELDI)--a new protein profiling tool utilizing specific carrier materials for time of flight mass spectrometric analysis.

Over the past couple of years, proteomics pattern analysis has emerged as an effective method for the early diagnosis of diseases such as ovarian, breast, or prostate cancer, without identification of single biomarkers. MALDI-TOF MS, for example, offers a simple approach for fast and reliable protein profiling, especially by using carrier materials with various physical and chemical properties, in combination with a MALDI matrix. This approach is referred to as material-enhanced laser desorption/ionization (MELDI). In this paper, we report the development and application of derivatized carrier materials [cellulose, silica, poly(glycidyl methacrylate/divinylbenzene) (GMA/DVB) particles, and diamond powder] for fast and direct MALDI-TOF MS protein profiling. The applicability of MELDI for rapid protein profiling was evaluated with human serum samples. These carriers, having various hydrophobicities, resulted in characteristic mass fingerprints, even if all materials were derivatized with iminodiacetic acid (IDA) to yield an immobilized metal affinity chromatography (IMAC) functionality. Our study demonstrates that analyzing complex biological samples, such as human serum, by employing different MELDI carrier materials yielded type- and size-dependent performance variation.

Indicators and Reagents↗

Strong binding of bioactive BMP-2 to nanocrystalline diamond by physisorption.

Nano-crystalline diamond (NCD)-coated surfaces were efficiently functionalized with bone morphogenetic protein-2 (BMP-2) by means of physisorption. Due to their randomly oriented texture, NCD-coated surfaces appear to bind complex molecules firmly. Applying various highly sensitive analytical methods, the interaction was found extremely stable. The strength of the experimentally measured adherence between BMP-2 and NCD was further corroborated by theoretical calculations. Oxygen treatment rendered NCD hydrophilic by the appearance of surface oxygen containing groups. This particular NCD surface exhibited even higher binding energies towards BMP-2 than the hydrophobic surface, and this surface was also favoured by cultured cells. Most importantly in this context, bound BMP-2 was found fully active. When cultured on BMP-2-treated NCD, osteosarcoma cells strongly up-regulated alkaline phosphatase, a specific marker for osteogenic differentiation. Hence, this simple method will allow generating highly versatile surfaces with complex biomimetic coatings, essentials for novel medical devices and implants as well as for innovative scaffolds in tissue engineering.

Absorption↗

Progress in capillary electrophoresis of biomarkers and metabolites between 2002 and 2005.

Biomarker discovery and metabolite research is a fast-growing and extremely important domain not only for the early detection of certain diseases but also for controlling its progress as well as in pharmaceutical investigations. For the analytical separation and identification, CE plays an indisputable role. Capillary systems enhancing different selectivity are applied and connected to different kind of detection systems. As the choice of buffer and its composition is responsible for a successful separation, special emphasis is put on solvent effects in this review. Altogether the most important capillary electrophoretic techniques applied for biomarker and metabolites analysis published between 2002 and 2005 are summarized and discussed.

Animals↗

Capillary electrochromatography of biologically relevant flavonoids.

Flavonoids were separated utilizing CEC technique. Baseline separation of biologically relevant flavonoids was obtained using a 100 microm ID fused-silica capillary filled with 3 microm Silica-C18 material and an optimized mobile phase comprising of 20 mM Tris-HCl (pH 6.5), ACN and water at a ratio of 10/40/50 v/v/v. Separations were carried out at 25 kV and a column temperature of 25 degrees C. The influence of relevant parameters for the CEC separation, such as buffer concentration, pH, separation voltage, and ACN concentration, was investigated and optimized. Dependencies of the electroendoosmotic flow (EOF) on these parameters and effects on the resolution of the analytes were studied. During analyses the solvents used for dissolving the samples turned out to have significant effects on the separation of flavonoids. The optimized system was then successfully used for the separation of the flavonoids epicatechin, myricetin, quercetin, naringenin, and hesperetin. CEC turned out to be a useful complementary tool for the economic analysis of flavonoids in addition to common HPLC, muHPLC, and CE methodologies. This method can be used for real applications in phytomics.

Camellia sinensis↗

Biomarker discovery in breast cancer serum using 2-D differential gel electrophoresis/ MALDI-TOF/TOF and data validation by routine clinical assays.

In the present study, we used 2-D differential gel electrophoresis (2-D DIGE) and MS to screen biomarker candidates in serum samples obtained from 39 patients with breast cancer and 35 controls. First, we pooled the serum samples matched with age and menopausal status. Then, we depleted the two most abundant proteins albumin and IgG by immunoaffinity chromatography under partly denaturing conditions in order to enrich low-abundance proteins and proteins with low molecular weight. Concentrated and desalted samples were labeled with three different CyDyes including one internal standard, pooled from all the samples, and separated with 2-D DIGE in triplicate experiments. Biological variations of the protein expression level were analyzed with DeCyder software and evaluated for reproducibility and statistical significance. The profile of differentially expressed protein spots between patients and controls revealed proapolipoprotein A-I, transferrin, and hemoglobin as up-regulated and three spots, apolipoprotein A-I, apolipoprotein C-III, and haptoglobin alpha2 as down-regulated in patients. Finally, routine clinical immunochemical reactions were used to validate selected candidate biomarkers by quantitative determination of specific proteins in all individual serum samples. The serum level of transferrin correlated well with the 2-D-DIGE results. However, the serum levels of apolipoprotein A-I and haptoglobin could not be detected with the clinical routine diagnostic tests. This demonstrated an advantage 2-D DIGE still has over other techniques. 2-D DIGE can distinguish between isoforms of proteins, where the overall immunochemical quantification does fail due to a lack of isoform-special antibodies.

Adult↗

Progress in capillary electrophoresis coupled to matrix-assisted laser desorption/ionization - time of flight mass spectrometry.

In this review the most important techniques developed to hyphenate CE to MALDI-TOF-MS are summarized. The principles of the different interfaces and ways to solve the hyphenation problem are explained and discussed in detail. The most important applications especially in the proteomic field are reviewed, and the advantages of CE-MALDI-TOF-MS for the analysis of these compounds compared to other techniques such as ESI-MS are exhaustingly discussed from a critical point of view. CE coupled to MALDI-TOF-MS has started to overpass traditionally used CE-coupling techniques, especially CE-ESI-MS, offering the possibility to analyze samples of interest even weeks after CE analysis and using multiplexing systems for high-sample throughput.

Electrophoresis, Capillary↗

Monolithic poly(glycidyl methacrylate-co-divinylbenzene) capillary columns functionalized to strong anion exchangers for nucleotide and oligonucleotide separation.

In the present work, poly(glycidyl methacrylate-co-divinylbenzene) monoliths were synthesized and further derivatized to obtain strong anion exchange supports. Capillary monoliths (65 x 0.2 mm id) were prepared in situ by copolymerization of glycidyl methacrylate and divinylbenzene, employing 1-decanol and tetrahydrofuran as porogens. The free epoxy groups were derivatized in a two step synthesis to obtain quaternary ammonium functionalities. On testing the pressure stability of the synthesized monolith, a highly linear dependence between flow rate and pressure drop was obtained, indicating the high stability of the material even at high flow rates. The morphology of the copolymer was investigated by scanning electron microscopy. Mercury intrusion porosimetry showed a narrow pore size distribution, having a maximum at 439 nm. On recording a van Deemter plot the number of theoretical plates per meter was found to be 59324. The produced strong anion exchange monoliths turned out to be highly suitable for the separation of nucleotides and oligonucleotides.

Benzene↗

Ultra-fast mass fingerprinting by high-affinity capture of peptides and proteins on derivatized poly(glycidyl methacrylate/divinylbenzene) for the analysis of serum and cell lysates.

The development of support materials in mass fingerprinting is an important task required for diagnostic markers in conjunction with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The material-based approach, which we introduced as material-enhanced laser desorption/ionization (MELDI), focuses not only on different functionalities, but also emphasizes the morphology, i.e. porosity or particle size of the carrier material. As a result, it provides a quick and sensitive platform for effective binding of peptides and proteins out of different biofluids, e.g. serum, spinal fluid, urine or cell lysates, and to subsequently analyze them with MALDI-TOF MS. This approach includes a built-in desalting step for serum protein profiling and is sensitive enough to detect proteins and peptides down to 100 fmol/microL. Here we co-polymerized glycidyl methacrylate (GMA) with divinylbenzene (DVB) using thermal polymerization to yield a GMA/DVB polymer for further modifications. Different affinities have been created, such as immobilized metal ion affinity (IDA-Cu2+), reversed-phase (RP) and anion-exchanger (AX) chromatography. The diverse derivatizations and the dispersity of the particles created by different chemical synthetic approaches were confirmed by characteristic infrared (IR) peaks. The polymerization carried out by non-stirring yielded an average pore radius of 6.1 microm (macro-pores) that enhanced the binding capacity enormously by offering enlarged surface areas. Moreover, atomic absorption spectrometry (AAS) provided the metal content loaded on iminodiacetic acid (IDA) in the case of poly(GMA/DVB)-IDA-Cu2+. To summarize, the optimized MELDI approach is sensitive in its performance, extremely fast and can be adapted to robotic systems for routine analysis, allowing sample preparation in less than 5 min in contrast to the conventional surface-enhanced laser desorption/ionization (SELDI) methods.

Blood Proteins↗

Oral peptide delivery: are there remarkable effects on drugs through sulfhydryl conjugation?

In oral peptide delivery, the gap between convenient administration and low blood concentration has to be minimized. We found that oral peptide drugs have not only to pass the various commonly known barriers encountered with the gastrointestinal tract but that these drugs, under certain conditions, have also to be seen as redox partners for thiol bearing substrates. The interaction of glutathione (GSH) with peptides via thiol-disulfide exchange reactions was investigated for three peptides, vasotocin, oxytocin and octreotide. The extent of thiol-disulfide exchange reactions was investigated by liquid chromatography (LC) and further confirmed by hyphenation to electrospray ionization (ESI) and MALDI-TOF mass spectrometry (MS). We found that the presence of aromatic amino acid residues in the neighbourhood of the disulfide bond minimizes the thiol-disulfide interaction: oxytocin was degraded more than 80% with 1% reduced glutathione at pH 3.0 and vasotocin more than 40% under the same conditions. In the case of octreotide no interaction with GSH was observed. The obtained results revealed that thiol-disulfide exchange reactions have an important impact on the alteration of peptide drugs and proteins in the gastrointestinal tract.

Administration, Oral↗

Quantitative detection of phosphoproteins by combination of two-dimensional difference gel electrophoresis and phosphospecific fluorescent staining.

Here we combine a standard two-dimensional difference gel electrophoresis (DIGE) protocol with subsequent post-staining of gels with phosphospecific fluorescent Pro-Q Diamond dye. The combination of these two methods for fluorescence detection of proteins allows quantitative detection of phosphoproteins in 2-DE-gels. We established this protocol within a functional proteomics experiment. Mammary epithelial cells (EpH4) were stimulated in culture by epidermal growth factor (EGF), endosomal fractions prepared after subcellular fractionation and phosphorylated proteins successfully detected on endosomes. For instance, Endo A cytokeratin, known as phosphoprotein and differentiation marker inducible by MAPK signaling, was identified by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). With this protocol, all steps of combined proteome and phosphoproteome profiling experiments are significantly simplified and accelerated, taking full advantage of both methods in terms of specificity, sensitivity and accuracy of quantification.

Animals↗

Enrichment of low-abundant serum proteins by albumin/immunoglobulin G immunoaffinity depletion under partly denaturing conditions.

We present a simple protocol for affinity depletion to remove the two most abundant serum proteins, albumin and immunoglobulin G (IgG). Under native conditions, albumin/IgG were efficiently removed and several proteins were enriched as shown by two-dimensional electrophoresis (2-DE). Besides that, partly denaturing conditions were established by adding 5 or 20% acetonitrile (ACN) in order to disrupt the binding of low-molecular-weight (LMW) proteins to the carrier proteins albumin/IgG. 2-DE results showed that the total number of detected LMW proteins increased under denaturing conditions when compared to native conditions. Interestingly, the presence of 5% ACN in serum revealed better enrichment of LMW proteins when compared to 20% ACN condition. Seven randomly distributed spots in albumin/IgG depleted serum samples under 5% ACN condition were picked from the 2-DE gels and identified by mass spectrometry (MS). The intensity of five LMW protein spots increased under denaturing conditions when compared to native conditions. Three of the seven identified spots (serum amyloid P, vitamin D-binding protein, and transthyretin) belong to a group of relatively low-abundant proteins, which make up only 1% of all serum proteins. The method presented here improves the resolution of the serum proteome by increasing the number of visualized spots on 2-D gels and allowing the detection and MS identification of LMW proteins and proteins of lower abundance.

Acetonitriles↗

Influence of the pore structure on the properties of silica based reversed phase packings for LC.

This paper describes the preparation and investigation of new, highly loaded, monomeric, silica based, reversed phase C18 and C30 packings. The influence of pore structure and endcapping on the properties of C18 and C30 packings is described. Using hydrothermal procedures, silicas with predictable pore size (9.3-25.5 nm) and surface area have been prepared. Silylation with long chain silanes substantially alters the pore structure of the silica: pore size and pore volume decrease. A new parameter, the volumetric surface coverage [mm3 x m(-2)] has been introduced. This parameter--calculated from on-column measured porosity data--indicates the pore volume portion occupied by the hydrocarbon chains. Endcapping does not significantly change the pore structure of the bonded phases. The reduced retentions (reduced with respect to unit area: [k/m2])--a good measure for comparing the retention behaviour of packings with different surface areas--are similar for most of the phases, demonstrating good accessibility of the pores for the solutes. Slightly lower retentions were found on the endcapped than on the non-endcapped phases for probes with dense pi-electron system (e.g. polyaromatic hydrocarbons) demonstrating the contribution of silanophilic interactions to the retention. The phases had been successfully used for various demanding separations, e.g. for the separation of flavonoids, carotenoids, resveratrol, and tocopherol isomers, fullerenes, and anions.

Chromatography, High Pressure Liquid↗

Phosphoproteomic analysis using immobilized metal ion affinity chromatography on the basis of cellulose powder.

Detailed characterization of phosphoproteins as well as other post-translationally modified proteins such as glycoproteins, is required to fully understand protein function and regulatory events in cells and organisms. Therefore, an experimental strategy for the isolation of phosphoproteins using a new immobilized metal ion affinity chromatograph (IMAC) material on the basis of cellulose has been developed and characterized. Different approaches have been used to test the material. Recovery rates were determined by 32P labelling of a myelin basic protein fragment and by reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry using a tryptic digest of the model protein bovine beta-casein. Selectivity was demonstrated by enrichment and separation of phosphopeptides from different samples, such as from a digest of horse myoglobin as well as from a digest of in vitro phosphorylated extracellular signal regulates kinase 2 (ERK2) mixed with synthetic phosphopeptides, phosphorylated on different amino acid residues. Furthermore, simplification and optimization of sample pretreatment was achieved by combining the separating (IMAC) and desalting (C18) step during preparative high performance liquid chromatography. The comparison between our material and a commercially available IMAC system (POROS 20 MC; Perspective BioSystems) emphasizes the competitiveness of the cellulose. Confirmed by the obtained data, the cellulose material performed as well as the commercially available sorbent, however with the advantage, that it can be produced rather easily and at very low cost.

Animals↗

Disruption of vascular endothelial homeostasis by tobacco smoke: impact on atherosclerosis.

The World Health Organization (WHO) predicts that by 2020 tobacco will become the largest single health problem worldwide and will cause an estimated 8.4 million deaths annually (http://www5.who.int/tobacco/). Although the impact of smoking on human health is well defined from the medical point of view, surprisingly little is known about the mechanisms by which tobacco smoke mediates its disastrous effects. Here, we demonstrate that tobacco smoke dramatically changes vascular endothelial cell and tissue morphology, leading to a loss of endothelial barrier function within minutes. Long-term exposure of endothelial cells to tobacco smoke extracts induces necrosis that may trigger a pro-inflammatory status of the vessel wall. Pre-incubation of the extracts without cells for 6 h at 37 degrees C led to a complete loss of activity. Further, the endothelium could be rescued by changing to fresh medium even at times when the extracts had lost their activity. Finally, we show that N-acetyl cysteine and statins inhibit the adverse tobacco smoke effects.

Acetylcysteine↗

Recent progress in high-performance capillary bioseparations.

Bioanalysis is a fast growing domain with new technological developments in the field of mass spectrometry, separation science, and bioinformatics. The central role of separation prior to detection and evaluation of analytes is indisputable. In fact, since the decipherment of the human genome via multichannel capillary electrophoresis in combination with laser-induced fluorescence [1], the analysis of the proteome, i.e., the type and amount of all proteins expressed at a certain time by the genome in a cell or tissue [2] became of central interest. Therefore, new fast and sensitive capillary liquid chromatographic, electrophoretic, and electrochromatographic separation techniques, suitable for high-throughput analysis of proteins, peptides and nucleic acids, are required.

Base Sequence↗