PubMed Health⌕ Search

Biomedical subjects

Christian W Pfirrmann

Publications and source records attributed to Christian W Pfirrmann.

4 recordsLinked to original sources

Injection studies in spinal disorders.

UNLABELLED: Spinal injections have an important role in many centers in the diagnostic assessment and treatment of patient with various spinal disorders. In the literature, many studies describe the application, techniques, and potential benefit of spinal infections. It is well accepted morphologic alterations and pain correlate weakly because many imaging findings in patients with spinal symptoms can be found in asymptomatic individuals. Accordingly, one rationale for spinal injections is to provoke or eliminate pain presumably caused by the target spinal structure; this ostensibly allows a physician to make a better assessment of whether a particular morphologic alteration does or does not cause symptoms. Another rationale is to use spinal injections to support conservative treatment in patients who have from nerve root compromise, spinal stenosis, or facet joint osteoarthritis. Despite the widespread use of these spinal injections, their application is based widely on anecdotal experience and evidence that is not evidence based. We highlight the need for prospective randomized trials on the clinical efficiency of spinal injections and stress the importance for future considerations of cost effectiveness to justify their further application. LEVEL OF EVIDENCE: Level V (expert opinion). See the Guidelines for Authors for a complete description of the levels of evidence.

Analgesics↗

Interosseous ligament tears of the wrist: comparison of multi-detector row CT arthrography and MR imaging.

PURPOSE: To compare the accuracy of multi-detector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers. MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multi-detector row CT arthrography was performed after tricompartmental injection of 3-6 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multi-detector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted kappa values for interobserver agreement were calculated for both imaging modalities. RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P = .62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P = .02). Interobserver agreement was better for multi-detector row CT arthrography (kappa = 0.37-0.78) than for MR imaging (kappa = -0.33 to -0.10). CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multi-detector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments.

Aged↗

Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement.

BACKGROUND: Glenoid loosening continues to be the primary reason for failure of total shoulder arthroplasty. The purpose of this study was to evaluate, with use of a sensitive and reproducible imaging method, the radiographic and clinical results of total shoulder replacement with a pegged, cemented polyethylene glenoid implant. METHODS: Forty-three patients (forty-seven shoulders) underwent a total shoulder replacement with a cemented polyethylene glenoid component with four threaded pegs. The patients were examined clinically, with fluoroscopically guided radiographs, and with computed tomography at an average of forty months. In addition to conventional scoring of radiographic lucency, an 18-point scoring system was used to quantify cement-peg lucencies in six zones of the back surface of the glenoid component as seen on computed tomography scans. RESULTS: On the average, the absolute Constant score improved from 39 points preoperatively to 70 points at the time of follow-up (p = 0.0001) and the pain score improved from 5 to 13 points (p = 0.001). The mean active anterior elevation improved by 34 degrees (p = 0.001) and the mean abduction, by 46 degrees (p = 0.006). Two patients had symptomatic glenoid loosening requiring revision. Twenty-one of the forty-seven shoulders had radiographic lucency around the glenoid pegs, and nine had progression of the lucency by at least two grades. Computed tomography detected lucencies, primarily at the bone-cement interface, in thirty-six shoulders. The scores for the lucencies seen on the computed tomography scans were associated with the radiographic lucency scores (p < 0.001), pain scores (p = 0.04), and abduction strength (p = 0.02). Computed tomography was more sensitive than radiography with regard to identifying the number of pegs associated with lucency and the size of the lucencies. The overall reproducibility of the scoring based on the computed tomography was higher than that of the radiographic scoring. CONCLUSIONS: Computed tomography provided a more sensitive and reproducible tool for the assessment of loosening of pegged glenoid components than did fluoroscopically guided conventional radiography. Further improvement in implant design and fixation technique appears to be necessary for long-term success of cemented glenoid components.

Adult↗

CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy--comparison of image-guidance techniques.

PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.

Adolescent↗