False-negative computed tomographic scan after a hyperextension dislocation injury of the cervical spine: a nearly missed diagnosis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Christina Kalogeropoulou.
Explore the source record for details and available documents.
We present a case of herpetic meningoencephalitis confirmed by PCR in a 22-y-old male, with accompanying appearance of a large intracerebral haematoma as a complication. Despite the impressive imaging findings, the final outcome of the patient's progress was favourable.
OBJECTIVE: The purpose of this study was to assess the clinical value and potential impact of SonoVue-enhanced sonography in the characterization of focal liver lesions. SUBJECTS AND METHODS: This study included 127 patients with 82 malignant and 52 benign lesions in the liver. Contrast-enhanced sonography was performed using nonlinear imaging modes at low mechanical index (0.1-0.3) to enable real-time visualization of arterial, portal, and late-phase enhancement. Digital recordings of unenhanced sonography and contrast-enhanced sonography were reviewed by on-site investigators and two off-site blinded interpreters. The final diagnosis was based on consensus interpreting of all examinations by another two expert observers with access to CT, MRI, and histologic data; the diagnostic accuracy of contrast-enhanced sonography in identifying the lesion as benign, malignant, or indeterminate and as actual tumor type was compared with baseline sonography. RESULTS: For on-site investigators, contrast-enhanced sonography reduced the number of indeterminate diagnoses by 67% and improved the sensitivity and specificity to 90.2% and 80.8%, respectively (p < 0.001). For off-site interpreters, contrast-enhanced sonography reduced the number of indeterminate diagnoses by 51-56% (p < 0.001); significantly improved sensitivity and specificity to 90.8-95.4% and 83.7-89.8%, respectively (p < 0.001); eliminated observers' variability (kappa coefficient: 0.66-0.77); and showed no significant difference in all comparisons in the analysis of lesions measuring less than 1.5 cm, 1.5-2.5 cm, and all sizes combined. Contrast-enhanced sonography did not rely on availability of clinical history to enable the diagnoses, and it reduced the need for further imaging investigations 23.7% to 90.4%. CONCLUSION: Contrast-enhanced sonography improves the characterization of focal liver lesions and may limit the need for further investigations.
BACKGROUND AND PURPOSE: To evaluate the feasibility and efficacy of external beam irradiation (EBI) for the prevention of re-stenosis due to neointimal hyperplasia, after percutaneous transluminal angioplasty (PTA) and stent placement of the superficial femoral artery. PATIENTS AND METHODS: A total of 60 patients with the diagnosis of superficial femoral artery stenoses or occlusions due to peripheral arterial obstructive disease underwent PTA and implantation of a self-expandable stent at their superficial femoral artery. After the procedure, patients were randomised and 30 of them received EBI (6 MV photons, total dose 24 Gy in six fractions in 2 weeks), while the rest 30 received no radiation therapy. RESULTS: EBI was technically feasible in all patients, without serious radiation related side effects. Overall, a statistically significant difference was observed in stenosis categories between the two groups at 6 months follow-up (P=0.04). More specifically, significantly more patients in the control group presented with stenosis greater or equal than 70% [EBI group 30% (9/30); control group 66.7% (20/30); P=0.009]. This difference in the percentage of re-stenosis had as a consequence significantly lower re-intervention rates among the patients of the irradiated group [17% (5/30) versus 47% (14/30); P=0.025] during the 6 months follow-up period. We also observed that the irradiated patients had re-stenosis at the stent ends, while the non-irradiated had re-stenosis at the stent ends and the lumen. Three of the irradiated patients, who discontinued the anti-platelet treatment, have shown thrombosis of the irradiated artery during the first month from the completion of the treatment. CONCLUSIONS: It is our belief that EBI is a feasible, safe and effective method for the prevention of neointimal hyperplasia at the superficial femoral artery. Further studies are deemed necessary to optimise the radiotherapy schedule.
OBJECTIVE: In the present study we have applied virtual endoscopy (VE) in patients with ureteral metallic stents as a follow-up tool study especially in the need to define ureteral patency. METHODS: We performed the suggested technique in 6 patients with malignant ureteral obstruction treated successfully by placement of Wallstent intraureteral metallic stents, and correlated the results with antegrade nephrostomography 48 hours after initial stent placement. RESULTS: In 2 patients restenosis was observed, and in the remaining 4 patients the stented ureters remained patent during the follow up evaluation. VE and antegrade nephrostomography, were concurrent as to their findings. Moreover, VE proceeds beyond the stenotic segment, allowing visualization of the ureteral lumen both cephalad and caudal to the point of obstruction. CONCLUSION: VE is providing indeed a more accurate, direct and dynamic approach in the evaluation of a strictured ureteral lumen within the metallic stent.
PURPOSE: We report our experience with auto-expandable metallic stents for treating ureteropelvic junction obstruction. MATERIALS AND METHODS: We treated 4 patients with a mean age of 45 years who had ureteropelvic junction obstruction with placement of a self-expandable intraureteral metallic stent (Wallstent, Schneider, Zurich, Switzerland). All patients presented with recurrent ureteropelvic junction obstruction after open pyeloplasty. Excretory urography and 3-dimensional reconstruction computerized tomography were performed 1 and 6 months after stent insertion. Virtual endoscopy images were obtained at followup due to the need to define ureteral patency. RESULTS: Mean followup was 16 months (range 9 to 24). Wallstent placement was successful and immediate patency was achieved in all cases. During followup 3 patients required no further intervention and the stented ureteropelvic junction remained patent. In the remaining patient stricture recurred 2 months after initial stent insertion due to the ingrowth of scar tissue through the prosthesis. Additional intervention was deemed necessary after placing a longer 6 cm., completely coaxial overlapping metal stent. Virtual endoscopy and excretory urography findings concurred. Virtual endoscopy allows visualization of the stented ureteropelvic junction lumen cephalad and caudal to the prosthesis. It also enables easy navigation within the stent at different angles of view. CONCLUSIONS: The concept of applying metallic stents for ureteropelvic junction obstruction and adjacent adynamic ureteral segments combined with virtual endoscopy is strengthened by the results of this study.
AIM: To investigate the possibility of covering PET-covered commercially available metallic stents, with liposomal dexamethasone that will act as a slow releasing drug-depot at the site of interest. METHODS: Large multilamellar (MLV), sonicated (SUV) and dried reconstituted (DRV) liposomes entrapping dexamethasone were prepared by thin film hydration, sonication and the DRV method, respectively, and applied on stents using a simple evaporation technique. Drug encapsulation and retention in liposomes were measured by HPLC. The presence of liposomes on the stent surface was confirmed by scanning electron microscopy, while the release of dexamethasone and lipid from the liposome-covered stent was evaluated under different conditions (flow rate, presence of plasma proteins), in an in vitro assembly that was developed to simulate in vivo conditions. RESULTS: The release of dexamethasone from liposome-covered stents ranged from 25% to 50% after 48 h of incubation in buffer, depending on the type of liposome. The release was highest from stents covered with DRV liposomes. When increasing the flow rate from 2 to 6 ml/min a slight increase in release of drug was observed, while a higher release was measured when stents were incubated in plasma proteins. Liposome size does not affect liposome placement on stents. CONCLUSION: The basic characteristics that should be considered when preparing liposomes to cover stents should be their drug loading capacity and their stability under the conditions prevailing at the site of interest. By preparing the appropriate formulation, it is possible that liposomal drugs may be used to cover stents and serve as drug releasing depots at the site of interest. Further in vitro and in vivo studies are needed in order to exploit the possible applications of this methodology.
OBJECTIVE: The purpose of the present study was to evaluate the use of externally coated stents in patients with malignant ureteral obstruction. MATERIALS AND METHODS: We have prospectively evaluated 16 patients, 10 men and 6 women, with malignant ureteral obstruction treated successfully by placement of Passager metal stents (Boston Scientific, Natick, MA, USA) bypassing the stricture. Mean patient age was 65.6 years (range 62-78 years). Ureteral patency was confirmed 24 and 48 hours by injection of contrast material through the nephrostomy tube, and after patency confirmation the nephrostomy catheter was removed. RESULTS: All stents were positioned successfully, and the postoperative course was uneventful. In 13 cases (81.2%) the prostheses finally migrated into the bladder hindering overall ureteral patency (mean time of migration: 1.5 months). Patency was achieved in the remaining ureters (n=3), during the follow-up period (mean: 8 months, range 6-16 months), without any need for further intervention. CONCLUSION: The inappropriate anchorage and the increased ureteral peristalsis are the main causes of migration towards the bladder, thus, minimizing the usefulness of this stent for the treatment of ureteral strictures.
PURPOSE: To evaluate the use of virtual endoscopy (VE) for the investigation of the pelvicaliceal unit and the depiction of its anatomic deformities. PATIENTS AND METHODS: Two study groups were prospectively enrolled in our protocol: ten patients with nonurologic pathologies, and thus without any known deformity of the pelvicaliceal unit (group A), and five patients with caliceal obstruction (group B). Virtual endoscopy represented a non-invasive technique providing amplification of the image in three-dimensional space. RESULTS: Virtual endoscopy was feasible in all patients, and in all cases succeeded in demonstrating the threedimensional morphology of the region of interest. The entire processing time ranged from 10 to 15 minutes (mean 12.6 minutes), and the three-dimensional image could be viewed from different angles, allowing better evaluation of the collecting system and its deformities than is possible with conventional intravenous urography or percutaneous nephrostomography. CONCLUSION: Virtual endoscopy enabled the creation of endoluminal views of the renal pelvis and calices from spiral tomographic images, thereby allowing diagnostic-preoperative and postoperative evaluation of the pelvicaliceal unit.
INTRODUCTION: Although the importance of the bronchial arteries is evident in modern day thoracic surgery, the significance of their communications with coronary arteries has yet to be appreciated, especially in cases of heart-lung transplantation and aortic aneurysm repair. We conducted a study to demonstrate the coronary-bronchial anastomotic routes in a porcine model using angiography and computed tomography. METHODS: Six young female white pigs were used. The heart and lungs were removed en bloc, including the lower trachea and oesophagus. Digital subtraction angiography of the bronchial circulation and spiral computed tomography scan were performed in a three-phase study before and after administration of contrast medium. This was achieved by infusion either into the cannulated bronchial artery or into the aortic root. Macroscopic evaluation was carried out using latex infusion into the bronchial or coronary circulation. RESULTS: We demonstrated communications between the bronchial and coronary systems in 5 of 6 subjects. This communication was located at the left atrial wall and the posterior and anterior wall of the left ventricle. In one case there were further anastomoses around the right atrial wall. CONCLUSIONS: There were communications between the left coronary arteries and the bronchial arteries in the majority of cases. Digital subtraction angiography and spiral computer tomography scan can demonstrate these communications directly and indirectly by measurements of contrast enhancement within the heart wall. Our study emphasises the importance of the bronchial arteries in cases of heart-lung transplantation and repair of thoracic aortic aneurysms.