Biomechanical strength of reconstruction plates when used for medial support of MED-El cochlear implants: implications for diagnostic MRI.

PURPOSE: It is hypothesized that a mesh reconstruction plate designed to fit a cochlear implant (CI) internal device will provide immediate structural support to the site of the implant and that this strength far exceeds the forces induced by a 1.5-tesla MRI. PROCEDURES: Human calvarial specimens were drilled and plated with reconstruction mesh. Force was applied until failure was reached. RESULTS: Mean maximum force, mean force to first failure and mean displacement measures for group 1 (resorbable mesh, n = 10) were 302.9 N, 283.0 N and 3.05 mm, respectively. The mean maximum force for group 2 (0.4-mm titanium mesh, n = 10) and group 3 (0.6-mm titanium mesh, n = 8), were 121.3 and 234.0 N, respectively. Mean force of first failure was 92.0 N for group 2 and 164.8 N for group 3. CONCLUSIONS: The force required for failure of the mesh is significantly greater than the 0.17 N exerted on a CI magnet by a 1.5-tesla MRI scan.

Absorbable Implants↗

Distortion of magnetic resonance images used in gamma knife radiosurgery treatment planning: implications for acoustic neuroma outcomes.

OBJECTIVE: To quantify the image distortion of our series of acoustic neuromas treated with gamma knife radiosurgery. STUDY DESIGN: Retrospective chart and digital radiographic file review with quantitative assessment of gamma knife treatment plans. SETTING: Tertiary referral center. PATIENTS: Patients undergoing gamma knife radiosurgery for the treatment of acoustic neuromas. INTERVENTION: Gamma knife radiosurgery. MAIN OUTCOME MEASURES: Gamma knife treatment plans containing magnetic resonance images were reviewed at each axial, sagittal, and coronal slice. The length of the greatest displacement of the treatment plan was measured and the volume of the treatment plan that fell outside of the internal auditory canal calculated. Known clinical measurements of audiometric, vestibular, facial, and trigeminal nerve functions were then compared with current measurements of tumor size. RESULTS: Twenty-two of the 23 patients had measurable image shifts on the axial images. The range of the image shift was 0 to 5.8 mm, with a mean shift of 1.92 +/- 1.29 mm (+/- standard deviation). Tumor volumes of the treatment plan that fell outside of the internal auditory canal ranged from 0 to 414 mm, with a mean of 90.5 mm. The mean percentage that fell outside of the internal auditory canal was 16.7% of total tumor volume (range, 2.4-77.6%). We could not draw any consistent correlations between degree of image shift and continued tumor growth or objective examination values. CONCLUSION: We have demonstrated a small but potentially significant shift in the treatment plan of gamma knife radiosurgery when based on magnetic resonance images. Although the image shift does not seem to affect the growth of the acoustic neuromas or auditory or facial nerve function, longer term follow-up is required to fully appreciate the true impact of this image shift.

Artifacts↗

Auditory sensitivity in children using the auditory steady-state response.

OBJECTIVE: To determine the effectiveness of auditory steady-state response (ASSR) as a measure of hearing sensitivity in young children suspect for significant hearing loss. DESIGN: Within-subject comparisons of click auditory brainstem response (ABR) thresholds and ASSR thresholds. SUBJECTS: The study population comprised 42 children suspect for hearing loss and subsequently referred for hearing assessment using electrophysiologic techniques. MAIN OUTCOME MEASURES: Electrophysiologic threshold responses for click ABR and ASSR stimuli (0.5, 1, 2, and 4 kHz) for right and left ears. RESULTS: Based on ABR and ASSR thresholds, 50% of the subjects demonstrated significant hearing loss in the severe to profound range. In some subjects, ASSRs were present at higher stimulus levels when click ABRs were absent. Significant correlations (P<.05) were found between high-frequency ASSR and click ABR thresholds for this study sample. For some subjects, ASSR findings suggested differences between ears that were not observable from the no-response click ABR results. CONCLUSIONS: Auditory steady-state response testing may provide additional information for children who demonstrate hearing levels in the severe to profound range. This information may be helpful when selecting the ear for cochlear implantation for a young hearing-impaired child. Multiple objective methods, such as ABR and ASSR testing, may be needed to determine accurate hearing sensitivity for young children being considered for sensory devices, and in particular, cochlear implants.

Audiometry, Pure-Tone↗

Response of the auditory nerve to sinusoidal electrical stimulation: effects of high-rate pulse trains.

Electrical stimulation of the auditory nerve produces highly synchronized responses. As a consequence, electrical stimulation may result in a narrow dynamic range of hearing and poor temporal representation of an input signal. The electrically evoked compound action potential (ECAP) is an electrophysiologic response used for neural assessment in individuals with auditory prostheses. Because the ECAP arises from the activity of a population of auditory nerve fibers, within- and across-fiber synchrony should be evident in the responses. Due to its clinical relevance and reflection of neural response properties, the ECAP is used in the present study to examine changes in neural synchrony. Empirical and modeled single-fiber data indicate that stimulation with electrical pulses of a sufficiently high rate may induce stochastic neural response behaviors. This study investigated the effects of adding high-rate conditioning pulses (5000 pps) on the ECAP in response to 100 Hz electrical sinusoids. The results showed that high-rate conditioning pulses increased response amplitudes at low sinusoidal levels and decreased the amplitudes at high sinusoidal levels, indicating a decrease in the slope of the ECAP growth functions to sinusoidal stimuli. The results are consistent with a hypothesis that high-rate conditioning pulses increase single-fiber relative spread (RS) in response to sinusoidal stimuli, and the effect is highly dependent on the level of the high-rate conditioning pulses.

Action Potentials↗

Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children.

OBJECTIVE: The purpose of this study was to intraoperatively record the electrically evoked auditory brainstem response (EABR) before and after placement of the electrode positioning system (EPS) (CII Bionic Ear with HiFocus I cochlear implant electrode array) as well as before and after stylet removal (Nucleus Contour cochlear implant electrode array). It was hypothesized that physiologic changes would occur after perimodiolar positioning of the electrode array and these changes would be evident from the EABR recordings. STUDY DESIGN: Consecutive young (11-36 month old) pediatric cochlear implant recipients (n = 17) had intraoperative EABRs recorded from three intracochlear electrodes that represented apical, medial, and basal locations. Wave V amplitudes and thresholds were studied relative to electrode location and pre- versus postperimodiolar positioning. These evoked potential measures were analyzed for statistical significance. SETTING: Tertiary referral children's hospital/medical college. RESULTS: Wave V thresholds of the EABR were lower, and amplitudes were larger after perimodiolar positioning, although the changes were dependent on electrode location and implant design. Statistically significant decreases in EABR wave V threshold and increases in suprathreshold wave V amplitude were found for the basal electrode for the CII Bionic Ear HiFocus I and for the apical electrode for the Nucleus Contour. CONCLUSIONS: Placement of either the CII Bionic Ear HiFocus I or Nucleus Contour cochlear implant electrode array in the perimodiolar position in young children resulted in less electrical current necessary to stimulate the auditory system. Changes in electrophysiologic thresholds and amplitudes, measured with EABR, indicate that the electrode array is placed closer to the modiolus with both electrode designs.

Child, Preschool↗

Connexin 26 and connexin 30 mutations in children with nonsyndromic hearing loss.

OBJECTIVES/HYPOTHESIS: Mutations in the connexin 26 (Cx26) or gap junction beta 2 gene are the leading cause of hereditary nonsyndromic sensorineural hearing loss in Caucasians. The Cx26 coding region of 68 children with nonsyndromic sensorineural hearing loss was sequenced to determine the frequency and type of Cx26 mutations in this population. Screening was also performed for a common connexin 30 (Cx30) or gap junction beta 6 mutation (del [GJB6-D13S1830]). Children also underwent audiological testing to determine whether any correlation exists between Cx26 mutations and severity of hearing loss. STUDY DESIGN: In all, 68 children with nonsyndromic sensorineural hearing loss were screened for Cx26 and Cx30 mutations by polymerase chain reaction and direct sequencing. METHODS: Genomic DNA was amplified by polymerase chain reaction using primers that flank the entire Cx26 coding region. Screening for the 342-kb Cx30 deletion was performed using primers that amplified the breakpoint junction of the deletion. The amplicons were then sequenced in both directions and analyzed for mutations. Audiometric testing, including pure-tone audiometry and auditory evoked brainstem response, was also performed to determine the degree of hearing loss. RESULTS: Twenty-seven of 68 children tested had mutations in Cx26 with 35delG being the most prevalent. Ten additional Cx26 mutations were detected including a novel compound heterozygote. Two children were heterozygous for the Cx30 del (GJB6-D13S1830) mutation. CONCLUSION: Cx26 and Cx30 mutations were present in 41.2% of children tested in the study population. Audiometric data supported previous studies demonstrating a greater degree of hearing loss in subjects who are homozygous for the 35delG mutation.

Adolescent↗

Effect of magnetic resonance imaging on internal magnet strength in Med-El Combi 40+ cochlear implants.

OBJECTIVE: Magnetic resonance imaging (MRI) has been contraindicated when cochlear implants containing an internal magnet are in place because of concerns regarding torque, force, demagnetization, artifacts, induced voltages, and heating. The objective was to determine the magnetic field strength of Med-El Combi 40+ cochlear implant internal magnets after MRI studies. STUDY DESIGN/METHODS: Two fresh cadavers were used to study demagnetization using a repeated measures design and a magnetometer. Pre- and postMRI measurement of magnetic field strength was completed. Five sets of sagittal T1-weighted, axial T1-weighted, and axial T2-weighted sequences were performed on a cadaver at 0.2 Tesla in the device-up and device-down positions. In the other cadaver, 15 sets of sagittal T1-weighted, axial T1-weighted, and axial T2-weighted sequences were performed on a cadaver at 1.5 Tesla were conducted, 5 each with the head oriented at 80, 90, and 100 degrees rotated around the yaw plane (rotated around the z-axis). Subsequently, three cochlear implant patients completed 0.2 Tesla MRIs. For these patients, subjective and objective assessment of cochlear implant performance was performed. SETTING: Academic medical center. RESULTS: In the cadaver studies, analysis of variance showed no significant difference in the magnetic field strength after the 0.2 or 1.5 Tesla scans. There was no significant difference in the magnetic field strength for the three patients undergoing 0.2 Tesla MRIs and no adverse consequences, including no changes in telemetry, auditory sensations, nonauditory sensations, and sound quality. CONCLUSIONS: No significant demagnetization of the internal magnet occurred during repeated 1.5 Tesla MRI scans with the head orientations used in this study. In the cochlear implant patients, no significant demagnetization of the internal magnet occurred after a 0.2 Tesla MRI.

Artifacts↗

Gamma knife radiosurgery for acoustic neuromas performed by a neurotologist: early experiences and outcomes.

OBJECTIVE: To assess early outcomes after Gamma knife radiosurgery of acoustic neuromas and other skull base tumors. BACKGROUND: Gamma knife radiosurgery is one of the available methods to treat acoustic neuromas, in addition to micro-surgical resection. Neuro-otologists have long been associated with microsurgical resection of these tumors; however, the application of Gamma knife radiosurgery to the treatment of these tumors by neuro-otologists has not been previously described. SETTING: Acoustic Neuroma and Skull Base Surgery Program / Tertiary Referral Center. STUDY DESIGN/PATIENTS/INTERVENTION: Prospective clinical study of all patients treated by the senior author and our gamma knife team beginning in June 2000. MAIN OUTCOME MEASURES: Preoperative MRI, audiometry, vestibular testing and facial nerve electromyography were completed. At six-month intervals postoperatively, audiometry, caloric testing and MRI were performed to determine thresholds and speech discrimination ability, vestibular function, and the size of the tumor. RESULTS: From June 2000 until March 2004, 38 patients were treated, and these included 33 acoustic neuromas, two meningiomas, one glomus jugulare tumor, and two facial neuromas. Greater than 36 month follow-up was available in 7 patients, > 24 months in 24, > 12 months in 31, and > 6 months in 34 patients. Statistically significant reduction in tumor size was seen over time, and tumor control was achieved in all but two patients. Various patterns of changes in auditory function, both in threshold and speech discrimination were observed in either positive or negative directions. CONCLUSIONS: Preliminary experience with Gamma knife radiosurgery indicates that this treatment method represents another option for neuro-otologists to use in managing patients with skull base tumors.

Follow-Up Studies↗

Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems.

OBJECTIVE: The purpose of this study was to conduct a large-scale investigation with adult recipients of the Clarion, Med-El, and Nucleus cochlear implant systems to (1) determine average scores and ranges of performance for word and sentence stimuli presented at three intensity levels (70, 60, and 50 dB SPL); (2) provide information on the variability of scores for each subject by obtaining test-retest measures for all test conditions; and (3) further evaluate the potential use of lower speech presentation levels (i.e., 60 and/or 50 dB SPL) in cochlear implant candidacy assessment. DESIGN: Seventy-eight adult cochlear implant recipients, 26 with each of the three cochlear implant systems, participated in the study. To ensure that the data collected reflect the range of performance of adult recipients using recent technology for the three implant systems (Clarion HiFocus I or II, Med-El Combi 40+, Nucleus 24M or 24R), a composite range and distribution of consonant-nucleus-consonant (CNC) monosyllabic word scores was determined. Subjects using each device were selected to closely represent this range and distribution of CNC performance. During test sessions, subjects were administered the Hearing in Noise Test (HINT) sentence test and the CNC word test at three presentation levels (70, 60, and 50 dB SPL). HINT sentences also were administered at 60 dB SPL with a signal-to-noise ratio (SNR) of +8 dB. Warble tones were used to determine sound-field threshold levels from 250 to 4000 Hz. Test-retest measures were obtained for each of the speech recognition tests as well as for warble-tone sound-field thresholds. RESULTS: Cochlear implant recipients using the Clarion, Med-El, or Nucleus devices performed on average equally as well at 60 compared with 70 dB SPL when listening for words and sentences. Additionally, subjects had substantial open-set speech perception performance at the softer level of 50 dB SPL for the same stimuli; however, subjects' ability to understand speech was poorer when listening in noise to signals of greater intensity (60 dB SPL + 8 SNR) than when listening to signals presented at a soft presentation level (50 dB SPL) in quiet. A significant correlation was found between sound-field thresholds and speech recognition scores for presentation levels below 70 dB SPL. The results demonstrated a high test-retest reliability with cochlear implant users for these presentation levels and stimuli. Average sound-field thresholds were between 24 and 29 dB HL for frequencies of 250 to 4000 Hz, and results across sessions were essentially the same. CONCLUSIONS: Speech perception measures used with cochlear implant candidates and recipients should reflect the listening challenges that individuals encounter in natural communication situations. These data provide the basis for recommending new candidacy criteria based on speech recognition tests presented at 60 and/or 50 dB SPL, intensity levels that reflect real-life listening, rather than 70 dB SPL.

Adult↗

Fungal biofilm formation on cochlear implant hardware after antibiotic-induced fungal overgrowth within the middle ear.

Cochlear implantation in patients with chronic suppurative otitis media is managed with perioperative antibiotics; however, fungal overgrowth can occur. We present a child who received oral cefdinir and topical ofloxacin (Floxin). After 6 weeks, a fungal (Candida) biofilm was demonstrated on the implant surface. In this clinical setting, an antimicrobial strategy using an oral antifungal to prevent fungal overgrowth is a possibility.

Anti-Infective Agents↗

Electrosurgery after cochlear implantation: eighth nerve electrophysiology.

HYPOTHESIS: Monopolar electrosurgery below the neck in cochlear implant recipients can be performed without damage to the internal cochlear stimulator, electrode array, and the cochlear nerve. STUDY DESIGN: Prospective pre- and postintervention electrically evoked compound action potential (ECAP) study of cochlear nerve function and behavioral sound perception assessment. METHODS: Neural response telemetry (NRT) was used to measure ECAPs before and after the use of monopolar electrosurgery during coronary artery bypass surgery to assess prosthetic device function and electrophysiologic function of the cochlear nerve. In addition, electrode voltage impedances and behavioral sound perception was measured at the same time intervals. RESULTS: ECAPs, behavioral sound perception, and electrode voltage impedances were within the normal range, within compliance, and similar preoperatively and on postoperative day 6. CONCLUSION: The studies reported herein were a series of measurements designed to test neural integrity and prosthetic device function before and after the use of monopolar electrosurgery. With appropriate precautions, use of monopolar electrosurgery below the neck in cochlear implant recipients can be performed safely.

Blood Loss, Surgical↗