PubMed Health⌕ Search

Biomedical subjects

Christof Baltes

Publications and source records attributed to Christof Baltes.

4 recordsLinked to original sources

k-t BLAST reconstruction from non-Cartesian k-t space sampling.

Current implementations of k-t Broad-use Linear Acqusition Speed-up Technique (BLAST) require the sampling in k-t space to conform to a lattice. To permit the use of k-t BLAST with non-Cartesian sampling, an iterative reconstruction approach is proposed in this work. This method, which is based on the conjugate gradient (CG) method and gridding reconstruction principles, can efficiently handle data that are sampled along non-Cartesian trajectories in k-t space. The approach is demonstrated on prospectively gated radial and retrospectively gated Cartesian imaging. Compared to a sliding window (SW) reconstruction, the resulting image series exhibit lower artifact levels and improved temporal fidelity. The proposed approach thus allows investigators to combine the specific advantages of non-Cartesian imaging or retrospective gating with the acceleration provided by k-t BLAST.

Artifacts↗

Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE.

Conventional phase-contrast velocity mapping in the ascending aorta was combined with k-t BLAST and k-t SENSE. Up to 5.3-fold net acceleration was achieved, enabling single breath-hold acquisitions. A standard phase-contrast (PC) sequence with interleaved acquisition of the velocity-encoded segments was modified to collect data in 2 stages, a high-resolution under sampled and a low-resolution fully sampled training stage. In addition, a modification of the k-t reconstruction strategy was tested. This strategy, denoted as "plug-in," incorporates data acquired in the training stage into the final reconstruction for improved data consistency, similar to conventional keyhole. "k-t SENSE plug-in" was found to provide best image quality and most accurate flow quantification. For this strategy, at least 10 training profiles are required to yield accurate stroke volumes (relative deviation <5%) and good image quality. In vivo 2D cine velocity mapping was performed in 6 healthy volunteers with 30-32 cardiac phases (spatial resolution 1.3 x 1.3 x 8-10 mm(3), temporal resolution of 18-38 ms), yielding relative stroke volumes of 106 +/- 18% (mean +/- 2*SD) and 112 +/- 15% for 3.8 x and 5.3 x net accelerations, respectively. In summary, k-t BLAST and k-t SENSE are promising approaches that permit significant scan-time reduction in PC velocity mapping, thus making high-resolution breath-held flow quantification possible.

Algorithms↗

Accelerated dynamic Fourier velocity encoding by exploiting velocity-spatio-temporal correlations.

OBJECTIVE: To describe how the information content in a Fourier velocity encoding (FVE) scan can be transformed into a very sparse representation and to develop a method that exploits the compactness of the data to significantly accelerate the acquisition. MATERIALS AND METHODS: For validation, fully sampled FVE datasets were acquired in phantom and in vivo experiments. Fivefold and eightfold acceleration was simulated by using only one fifth or one eighth of the data for reconstruction in the proposed method based on the k-t BLAST framework. Reconstructed images were compared quantitatively to those from the fully sampled data. RESULTS: Velocity spectra in the accelerated datasets were comparable to the spectra from fully sampled datasets. The detected peak velocities remained accurate even at eightfold acceleration, and the overall shape of the spectra was well preserved. Slight temporal smoothing was seen in the accelerated datasets. CONCLUSION: A novel technique for accelerating time-resolved FVE scan is presented. It is possible to accelerate FVE to acquisition speeds comparable to a standard time-resolved phase-contrast scan.

Algorithms↗

Retrospective respiratory motion correction for navigated cine velocity mapping.

In general, high spatial and temporal resolutions in cine cardiac imaging require long scan times, making breath-hold acquisition impossible in many cases. To enable free-breathing cardiac imaging, methods such as navigator gating were developed to reduce image artifacts due to respiratory motion. Nevertheless, residual image blurring is seen in images acquired late in the cardiac cycle. Image blurring itself hampers accurate blood flow quantification, especially in vessels exhibiting high flows during diastole. In the present work, the navigator gating and slice tracking method was extended by using navigator information to correct for in-slice motion components throughout the cardiac cycle. For this purpose, a standard two-dimensional (2D) cine phase contrast sequence with navigator gating and slice position correction was used, and navigator information was recorded along with the raw k-space data. In postprocessing, in-plane motion components arising from respiration during the actual data acquisition were estimated and corrected according to the Fourier shift theorem. In phantom experiments, the performance of the correction algorithm for different slice angulations with respect to the navigator orientation was validated. In vivo, coronary flow measurements were performed in 9 healthy volunteers. The correction algorithm led to considerably improved vessel sharpness throughout the cardiac cycle in all measured subjects [increase in vessel sharpness: 16+/-11% (mean+/-SD)]. Furthermore, these improvements resulted in increased volume flow rates [16+/-13% (mean+/-SD)] after retrospective correction indicating the impact of the method. It is concluded that retrospective respiratory motion corrections for navigated cine two-dimensional (2D) velocity mapping can correct for in-plane motion components, providing better image quality for phases acquired late in the cardiac cycle. Therefore, this method holds promise in particular for free-breathing coronary flow quantification.

Blood Flow Velocity↗