PubMed Health⌕ Search

Biomedical subjects

Christoph Hintermüller

Publications and source records attributed to Christoph Hintermüller.

2 recordsLinked to original sources

Cardiac anisotropy: is it negligible regarding noninvasive activation time imaging?

The aim of this study was to quantify the effect of cardiac anisotropy in the activation-based inverse problem of electrocardiography. Differences of the patterns of simulated body surface potential maps for isotropic and anisotropic conditions were investigated with regard to activation time (AT) imaging of ventricular depolarization. AT maps were estimated by solving the nonlinear inverse ill-posed problem employing spatio-temporal regularization. Four different reference AT maps (sinus rhythm, right-ventricular and septal pacing, accessory pathway) were calculated with a bidomain theory based anisotropic finite-element heart model in combination with a cellular automaton. In this heart model a realistic fiber architecture and conduction system was implemented. Although the anisotropy has some effects on forward solutions, effects on inverse solutions are small indicating that cardiac anisotropy might be negligible for some clinical applications (e.g., imaging of focal events) of our AT imaging approach. The main characteristic events of the AT maps were estimated despite neglected electrical anisotropy in the inverse formulation. The worst correlation coefficient of the estimated AT maps was 0.810 in case of sinus rhythm. However, all characteristic events of the activation pattern were found. The results of this study confirm our clinical validation studies of noninvasive AT imaging in which cardiac anisotropy was neglected.

Action Potentials↗

Sensitivity- and effort-gain analysis: multilead ECG electrode array selection for activation time imaging.

Methods for noninvasive imaging of electric function of the heart might become clinical standard procedure the next years. Thus, the overall procedure has to meet clinical requirements as an easy and fast application. In this paper, we propose a new electrode array which improves the resolution of methods for activation time imaging considering clinical constraints such as easy to apply and compatibility with routine leads. For identifying the body-surface regions where the body surface potential (BSP) is most sensitive to changes in transmembrane potential (TMP), a virtual array method was used to compute local linear dependency (LLD) maps. The virtual array method computes a measure for the LLD in every point on the body surface. The most suitable number and position of the electrodes within the sensitive body surface regions was selected by constructing effort gain (EG) plots. Such a plot depicts the relative attainable rank of the leadfield matrix in relation to the increase in number of electrodes required to build the electrode array. The attainable rank itself was computed by a detector criterion. Such a criterion estimates the maximum number of source space eigenvectors not covered by noise when being mapped to the electrode space by the leadfield matrix and recorded by a detector. From the sensitivity maps, we found that the BSP is most sensitive to changes in TMP on the upper left frontal and dorsal body surface. These sensitive regions are covered best by an electrode array consisting of two L-shaped parts of approximately 30 cm x 30 cm and approximately 20 cm x 20 cm. The EG analysis revealed that the array meeting clinical requirements best and improving the resolution of activation time imaging consists of 125 electrodes with a regular horizontal and vertical spacing of 2-3 cm.

Action Potentials↗