PubMed Health⌕ Search

Biomedical subjects

Christoph Juchem

Publications and source records attributed to Christoph Juchem.

5 recordsLinked to original sources

Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields.

The use of high magnetic fields increases the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS) of brain metabolites. Practical limitations arise, however, from susceptibility-induced field distortions, which are increased at higher magnetic field strengths. Solutions to this problem include optimized shimming, provided that active, i.e., electronic, shimming can operate over a sufficient range. To meet our shim requirements, which were an order of magnitude greater than the active shim capacity of our 7T MR system, we developed a combined passive and active shim approach. Simple geometries of ferromagnetic shim elements were derived and numerically optimized to generate a complete set of second-order spherical harmonic shim functions in a modular manner. The major goals of the shim design were maximization of shim field accuracy and ease of practical implementation. The theoretically optimized ferro-shim geometries were mounted on a cylindrical surface and placed inside the magnet bore, surrounding the subject's head and the RF coil. Passive shimming generated very strong shim fields and eliminated the worst of the field distortions, after which the field was further optimized by flexible and highly accurate active shimming. Here, the passive-shimming procedure was first evaluated theoretically, then applied in phantom studies and subsequently validated for in vivo 1H MRS in the macaque visual cortex. No artifacts due to the passive shim setup were observed; adjustments were reproducible between sessions. The modularity and the reduction to two pieces per shim term in this study is an important simplification that makes the method applicable also for passive shimming within single sessions. The feasibility of very strong, flexible and high-quality shimming via a combined approach of passive and active shimming is of great practical relevance for MR imaging and spectroscopy at high field strengths where shim power is limited or where shimming of specific anatomical regions inherently requires strong shim fields.

Algorithms↗

Simultaneous EEG and fMRI in the macaque monkey at 4.7 Tesla.

Simultaneous electroencephalography (EEG)/functional magnetic resonance imaging (fMRI) acquisition can identify the brain networks involved in generating specific EEG patterns. Yet, the combination of these methodologies is hampered by strong artifacts that arise due to electromagnetic interference during magnetic resonance (MR) image acquisition. Here, we report corrections of the gradient-induced artifact in phantom measurements and in experiments with an awake behaving macaque monkey during fMRI acquisition at a magnetic field strength of 4.7 T. Ninety-one percent of the amplitude of a 10 microV, 10 Hz phantom signal could successfully be recovered without phase distortions. Using this method, we were able to extract the monkey EEG from scalp recordings obtained during MR image acquisition. Visual evoked potentials could also be reliably identified. In conclusion, simultaneous EEG/fMRI acquisition is feasible in the macaque monkey preparation at 4.7 T and holds promise for investigating the neural processes that give rise to particular EEG patterns.

Animals↗

High-resolution (1)H chemical shift imaging in the monkey visual cortex.

Functionally distinct anatomic subdivisions of the brain can often be only a few millimeters in one or more dimensions. The study of metabolic differences in such structures by means of localized in vivo MR spectroscopy is therefore challenging, if not impossible. In fact, the spatial resolution of chemical shift imaging (CSI) in humans is typically in the range of centimeters. The aim of the present study was to optimize (1)H CSI in monkeys and demonstrate the feasibility of high spatial resolutions up to 1.4 x 2 x 1.4 mm(3). The obtained spatial resolution permitted the segregation of gray and white matter in the visual cortex based on the concentration of different metabolites and neurotransmitters like N-acetylaspartate, glutamate, and creatine. Concentration ratios of white matter versus gray matter tissue as well as between metabolites matched those reported in the literature from healthy human brain, demonstrating the consistency and reliability of the procedure.

Animals↗

High-field localized 1H NMR spectroscopy in the anesthetized and in the awake monkey.

Localized cerebral in vivo 1H NMR spectroscopy (MRS) was performed in the anesthetized as well as the awake monkey using a novel vertical 7 T/60 cm MR system. The increased sensitivity and spectral dispersion gained at high field enabled the quantification of up to 16 metabolites in 0.1- to 1-ml volumes. Quantification was accomplished by using simulations of 18 metabolite spectra and a macromolecule (MM) background spectrum consisting of 12 components. Major cerebral metabolites (concentrations >3 mM) such as glutamate (Glu), N-acetylaspartate (NAA), creatine (Cr)/phosphocreatine (PCr) and myo-inositol (Ins) were identified with an error below 3%; most other metabolites were quantified with errors in the order of 10%. Metabolite ratios were 1.39:1 for total NAA, 1.38:1 for glutamate (Glu)/glutamine (Gln) and 0.09:1 for cholines (Cho) relative to total Cr. Taurine (Tau) was detectable at concentrations lower than 1 mM, while lactate (Lac) remained below the detection limit. The spectral dispersion was sufficient to separate metabolites of similar spectral patterns, such as Gln and Glu, N-acetylaspartylglutamate (NAAG) and NAA, and PCr-Cr. MRS in the awake monkey required the development and refinement of acquisition and correction strategies to minimize magnetic susceptibility artifacts induced by respiration and movement of the mouth or body. Periods with major motion artifacts were rejected, while a frequency/phase correction was performed on the remaining single spectra before averaging. In resting periods, both spectral amplitude and line width, that is, the voxel shim, were unaffected permitting reliable measurements. The corrected spectra obtained from the awake monkey afforded the reliable detection of 6-10 cerebral metabolites of 1-ml volumes.

Anesthesia, General↗

Region and volume dependencies in spectral line width assessed by 1H 2D MR chemical shift imaging in the monkey brain at 7 T.

High magnetic fields increase the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS). In contrast, spectral peaks are broadened in vivo at higher field strength due to stronger susceptibility-induced effects. Strategies to minimize the spectral line width are therefore of critical importance. In the present study, 1H 2D chemical shift imaging at short echo times was performed in the macaque monkey brain at 7 T. Large brain coverage was obtained at high spatial resolution with voxel sizes down to 50 microl being able to quantify up to nine metabolites in vivo with good reliability. Measured line widths of metabolites decreased from 14.2 to 7.6 Hz with voxel volumes of 3.14 ml to 50 microl (at increased spatial resolution). The line width distribution of the metabolites (7.6+/-1.6 Hz, ranging from 5.5 to 10 Hz) was considerably smaller compared to that of water (10.6+/-2.4 Hz) and was also smaller than reported in 1H MRS at 7 T in the human brain. Our study showed that even in well-shimmed areas assumed to have minimal macroscopic susceptibility variations, spectral line widths are tissue-specific exhibiting considerable regional variation. Therefore, an overall improvement of a gross spectral line width--directly correlated with improved spectral quality--can only be achieved when voxel volumes are significantly reduced. Our line width optimization was sufficient to permit clear glutamate (Glu)-glutamine separation, yielding distinct Glu maps for brain areas including regions of greatly different Glu concentration (e.g., ventricles vs. surrounding tissue).

Animals↗